A New Low Switching Frequency Control of Regenerative CHB Drive With Low-Voltage Ride-Through Capability

被引:5
|
作者
Ni, Zhituo [1 ]
Abuelnaga, Ahmed H. [1 ]
Badawi, Sarah [2 ]
Yuan, Shaoyi [2 ]
Narimani, Mehdi [2 ]
Sayed-Ahmed, Ahmed [3 ]
Cheng, Zhongyuan [1 ]
Zargari, Navid R. [1 ]
机构
[1] Rockwell Automat Inc, Cambridge, ON N1R 5N9, Canada
[2] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada
[3] Rockwell Automat Inc, Milwaukee, WI 53204 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Harmonic analysis; Insulated gate bipolar transistors; Switching frequency; Switches; Control systems; Transformers; IEEE Standards; Low grid voltage ride-through; low-frequency modulation strategy; multilevel regenerative drives; POWER QUALITY; SPEED DRIVES;
D O I
10.1109/TPEL.2022.3216001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In conventional medium-voltage high-power cascaded H-bridge (CHB) drive, a three-phase rectifier is adopted in each power cell to provide isolated dc-bus voltage for the output H-bridge. This limits the application of the conventional CHB drive, where regeneration capability is desired. The regenerative CHB drive can be made possible by replacing the diode rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, due to thermal constraints in the high-power medium-voltage drives, the first challenge of the regenerative CHB drive is to deal with the extra switching losses introduced by the IGBT devices. Another challenge of the grid-tied regenerative CHB drive is to handle the low-voltage sags in the power grid without triggering unnecessary downtime in transients. In this article, a novel low-switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive with low-voltage ride-through (LVRT) capability. The main harmonic contents generated by the AFEs with the proposed control strategy can be eliminated by the existing phase-shifting transformer in the CHB drives. This allows meeting with IEEE STD 519-2014 requirement with a 60 Hz switching frequency to minimize the extra introduced switching losses in steady state. Moreover, LVRT capability is integrated into the proposed control scheme with reduced current sensor count. Accompanied with videos, the experiments on a seven-level regenerative CHB drive are implemented to validate the feasibility of the proposed control scheme, which can be extended to regenerative CHB drives with any voltage levels.
引用
收藏
页码:1973 / 1983
页数:11
相关论文
共 50 条
  • [31] Coordination of mode switching control and SMES unit for low-voltage ride-through fulfillment of power electronic transformer
    Chen, Lei
    Qiao, Xuefeng
    Zhao, Zekai
    Wang, Xuechun
    Chen, Hongkun
    Li, Yanhong
    Islam, Md Rabiul
    Deng, Xinyi
    Li, Guocheng
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (03) : 993 - 1008
  • [32] An integrated reactive power control strategy for improving low voltage ride-through capability
    Gatavi E.
    Hellany A.
    Nagrial M.
    Rizk J.
    Chinese J. Electr. Eng., 4 (1-14): : 1 - 14
  • [33] An adaptive control strategy of crowbar for the low voltage ride-through capability enhancement of DFIG
    Jiang, Huilan
    Zhang, Chi
    Zhou, Tao
    Zhang, Yanxia
    Zhang, Fang
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 601 - 606
  • [34] Determination strategies of low-voltage ride-through/ zero-voltage ride-through curves in Taiwan grid codes
    Yang, Nien-Che
    Yang, Huai-Yuan
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 227
  • [35] Design of mode switching scheme for low-voltage ride-through of doubly fed induction generators
    Wei, Feng
    Vilathgamuwa, Don Mahinda
    Shing, Choi San
    IET RENEWABLE POWER GENERATION, 2015, 9 (02) : 109 - 119
  • [36] Multilevel cascaded three-phase inverter with low-voltage ride-through flexible control capability for photovoltaic systems
    Albasri, Omar Kanaan
    Ercelebi, Ergun
    PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2020, 69 (04) : 331 - 345
  • [37] Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement
    Rahimi, M.
    Parniani, M.
    IET RENEWABLE POWER GENERATION, 2010, 4 (03) : 242 - 252
  • [38] Resonant control system for low-voltage ride-through in wind energy conversion systems
    Cardenas, Roberto
    Diaz, Matias
    Rojas, Felix
    Clare, Jon
    Wheeler, Pat
    IET POWER ELECTRONICS, 2016, 9 (06) : 1297 - 1305
  • [39] Low-voltage ride-through for PV systems using model predictive control approach
    Diaz-Franco, Fernand
    Vu, Tuyen
    El Mezyani, Touria
    Edrington, Chris S.
    2016 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2016,
  • [40] Low-Voltage Ride-Through Capability of Flyback Inverter Under BCM Operation for AC Module Applications
    Ansari, Sajad Arab
    Hosseinian, S. Hossein
    Moghani, Javad Shokrollahi
    2017 SMART GRID CONFERENCE (SGC), 2017,