Low-Voltage Ride-Through Capability of Flyback Inverter Under BCM Operation for AC Module Applications

被引:0
|
作者
Ansari, Sajad Arab [1 ]
Hosseinian, S. Hossein [1 ]
Moghani, Javad Shokrollahi [1 ]
机构
[1] Amirkabir Univ Technol, Dept Elect Engn, Tehran, Iran
关键词
Boundary conduction mode (BCM); flyback inverter; low-voltage ride-through(LVRT); microinverter;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Under voltage rise/drop conditions, grid-connected distributed generation systems have to be disconnected from the grid. However, due to the increasing number of grid-connected PV systems, the future photovoltaic (PV) systems should become more active and support low-voltage ride-through (LVRT) capability. The aim of this paper is to show a new advantage of the flyback inverter under boundary conduction mode (BCM) for supporting LVRT capability without using any auxiliary control system and any limitation in designing of the parameters. The detailed operation of the flyback inverter under increasing and decreasing conditions of the grid voltage for BCM operation are presented. Finally, simulation results based on the flyback inverter under grid faults are demonstrated. The results elucidate that the flyback inverter under BCM operation can support LVRT capability for Ac module application in distributed generation systems, without any limitation in parameters design and any additional control system.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Hybrid-Mode Cuk Inverter with Low-Voltage Ride-Through Capability under Grid-Faults
    Han, Byeongcheol
    Kim, Minsung
    Lai, Jih-Sheng
    2019 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE 2019 - ECCE ASIA), 2019,
  • [2] Low-voltage Ride-through Capability Characterization of Wind Farms
    Awad, A. S.
    Abdel-Rahman, M.
    Badr, M. Abdel Latif
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (16) : 1808 - 1819
  • [3] Low-voltage ride-through concept in flyback inverter-based alternating current-photovoltaic modules
    Papanikolaou, Nick P.
    IET POWER ELECTRONICS, 2013, 6 (07) : 1436 - 1448
  • [4] PV Power System With Multi-Mode Operation and Low-Voltage Ride-Through Capability
    Tang, Cheng-Yu
    Chen, Yao-Ting
    Chen, Yaow-Ming
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (12) : 7524 - 7533
  • [5] Enhanced low-voltage ride-through capability of flying capacitors inverter using model predictive control
    Trabelsi, Mohamed
    Ben-Brahim, Lazhar
    Gastli, Adel
    Abu-Rub, Haitham
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2017, 27 (12):
  • [6] Power source with low-voltage ride-through capability for auxiliary equipment inverter of thermal power plant
    Wang, Xiaoyu
    Zhang, Tao
    Liu, Shu
    Cao, Fengmei
    Liu, Zhichao
    Yang, Qixun
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2015, 35 (05): : 152 - 159
  • [7] A Review of the Low-Voltage Ride-Through Capability of Wind Power Generators
    Hu, Yi-Liang
    Wu, Yuan-Kang
    Chen, Chiu-Kuo
    Wang, Chih-Hua
    Chen, Wei-Tan
    Cho, Liang-Il
    POWER AND ENERGY SYSTEMS ENGINEERING, (CPESE 2017), 2017, 141 : 378 - 382
  • [8] Design of a Microgrid with Low-Voltage Ride-Through Capability and Simulation Experiment
    Fan, Wenchao
    Wu, Zaijun
    Dou, Xiaobo
    Hu, Minqiang
    Wei, Jieru
    Lv, Zhenyu
    JOURNAL OF APPLIED MATHEMATICS, 2014,
  • [9] A Flexible Low-Voltage Ride-Through Operation for the Distributed Generation Converters
    Chen, Hsin-Chih
    Lee, Chia-Tse
    Cheng, Po-Tai
    Teodorescu, Remus
    Blaabjerg, Frede
    Bhattacharya, Subhashish
    2013 IEEE 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (IEEE PEDS 2013), 2013, : 1354 - 1359
  • [10] Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage Restorers
    Ramirez, Dionisio
    Martinez, Sergio
    Platero, Carlos A.
    Blazquez, Francisco
    de Castro, Rosa M.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 195 - 203