Metal organic framework/clay composite for micro-dispersive solid-phase extraction of sulfonamides and penicillins in milk, and synthetic urine solution coupling with HPLC/DAD detection

被引:12
|
作者
Aldoori, Mahmood Saad [1 ]
Merdivan, Melek [2 ]
Tagac, Aylin Altinisik [2 ,3 ]
机构
[1] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Tinaztepe Campus, TR-35160 Izmir, Turkiye
[2] Dokuz Eylul Univ, Chem Dept, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[3] Dokuz Eylul Univ, Ctr Fabricat & Applicat Elect Mat, TR-35390 Izmir, Turkiye
关键词
MMT; MOF; mu-dSPE; Antibiotics; HPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANTIBIOTIC-RESIDUES; WATER; SORBENT; MICROEXTRACTION; SAMPLES; MONTMORILLONITE; ADSORPTION; AMPICILLIN; POLYMER;
D O I
10.1016/j.microc.2022.108165
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, composite as a copper-containing metal-organic framework with montmorillonite (MMT) clay was synthesized and applied as an adsorbent for micro-dispersive solid-phase extraction (mu-dSPE) of sulfonamides (SAs) and penicillins (PENs). The synthesized composites including different content of MMT were characterized by Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, Brunauer-Emmett-Teller surface area, and thermogravimetric analysis. The determination of antibiotics was performed by high-performance liquid chromatography/diode array detection (HPLC/DAD) using C18 column as stationary phase, 0.1 % trifluoroacetic acid in water, and acetonitrile as mobile phase in gradient mode and detection at 270 nm for SAs and 230 nm for PENs. The as-synthesized composites were examined for their adsorption ability towards target antibiotics. The optimized parameter conditions were 10 mg of adsorbent, 5 mL of sample solution at pH 4, 10 min stirring by vortex, 1 mL of acetonitrile:methanol (1:1) as eluent solvent, and 5 min as elution time. Under optimized conditions, the proposed method presented good linearity from 0.5 to 400 mu g/L for SAs and from 1 to 400 mu g/L for PENs with coefficients of determination (r(2)) >= 0.9947, low limit of detections from 0.10 to 0.15 mu g/L for SAs and 0.30 to 1.50 mu g/L for PENs, acceptable repeatabilities less than 3.26 % for both groups and good recoveries from 82.3 % to 116.4 % with relative standard deviations less than 3.9 % for both groups in the spiked milk samples and synthetic urine solution. The developed mu-dSPE method following HPLC/DAD has been successfully applied to the determination of SAs and PENs milk samples and synthetic urine solutions.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Dispersive solid-phase extraction using the metal-organic framework MIL-101(Cr) for determination of benzo(a)pyrene in edible oil
    Lv, Zhiyang
    Yang, Cheng
    Pang, Yuehong
    Xie, Weiying
    Shen, Xiaofang
    ANALYTICAL METHODS, 2019, 11 (27) : 3467 - 3473
  • [42] A cadmium(II)-based metal-organic framework material for the dispersive solid-phase extraction of polybrominated diphenyl ethers in environmental water samples
    Su, Hao
    Wang, Ze
    Jia, Yuqian
    Deng, Liulin
    Chen, Xiangfeng
    Zhao, Rusong
    Chan, T. -W. Dominic
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1422 : 334 - 339
  • [43] A novel dispersive solid-phase extraction method using metal-organic framework MIL-101 as the adsorbent for the analysis of benzophenones in toner
    Li, Ning
    Zhu, Quanfei
    Yang, Yang
    Huang, Jianlin
    Dang, Xueping
    Chen, Huaixia
    TALANTA, 2015, 132 : 713 - 718
  • [44] Dispersive micro-solid phase extraction of bisphenol A from milk using magnetic nylon 6 composite and its final determination by HPLC-UV
    Reyes-Gallardo, Emilia M.
    Lucena, R.
    Cardenas, S.
    Valcarcel, M.
    MICROCHEMICAL JOURNAL, 2016, 124 : 751 - 756
  • [45] Amino-Functionalized Metal Organic Framework-Based Dispersive Micro-Solid-Phase Extraction Coupled With HPLC for Sensitive Quantification of Bisphenol A and Alkyl Phenols in Aqueous Samples
    Verma, Rajpal
    Dhingra, Gaurav
    Singh, Gurdeep
    Dureja, Nidhi
    Malik, Ashok Kumar
    SEPARATION SCIENCE PLUS, 2024, 7 (10):
  • [46] Determination of tetramethylenedisulfotetramine in human urine with gas chromatograph-flame thermionic detection coupling with direct immersed solid-phase micro-extraction
    Zeng, Dong
    Chen, Bo
    Yao, Shouzhuo
    Ying, Jianying
    FORENSIC SCIENCE INTERNATIONAL, 2006, 159 (2-3) : 168 - 174
  • [47] Determination of sulfonamide residues in animal foodstuffs by magnetic dispersive solid-phase extraction using magnetic carbon nanocomposites coupled with ion pair-dispersive liquid-liquid micro-extraction combined with HPLC-DAD
    Yazdanfar, Najmeh
    Shamsipur, Mojtaba
    Ghambarian, Mahnaz
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2021, 18 (06) : 1433 - 1442
  • [48] Determination of trace bisphenols in milk based on AMA/DVB@GO@UiO-66-NH2 dispersive micro solid-phase extraction coupled with HPLC–UV
    Weixia Li
    Jiacheng Lei
    Tiancheng He
    Yaping Gan
    Yan Zhu
    Microchimica Acta, 2025, 192 (5)
  • [49] Development of a sample preparation procedure using an iron-based metal-organic framework for the extraction of pesticides from fruit juices by dispersive micro solid-phase extraction followed by their preconcentration by dispersive liquid-liquid microextraction
    Pezhhanfar, Sakha
    Farajzadeh, Mir Ali
    Hosseini-Yazdi, Seyed Abolfazl
    Mogaddam, Mohammad Reza Afshar
    SEPARATION SCIENCE PLUS, 2022, 5 (05) : 184 - 192
  • [50] A stable core-shell metal-organic framework@covalent organic framework composite as solid-phase extraction adsorbent for selective enrichment and determination of flavonoids
    Ma, Mingcai
    Lu, Xiaofeng
    Wang, Licheng
    Guo, Yong
    Ding, Hui
    Wang, Shuai
    Liang, Xiaojing
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1707