Metal organic framework/clay composite for micro-dispersive solid-phase extraction of sulfonamides and penicillins in milk, and synthetic urine solution coupling with HPLC/DAD detection

被引:12
|
作者
Aldoori, Mahmood Saad [1 ]
Merdivan, Melek [2 ]
Tagac, Aylin Altinisik [2 ,3 ]
机构
[1] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Tinaztepe Campus, TR-35160 Izmir, Turkiye
[2] Dokuz Eylul Univ, Chem Dept, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[3] Dokuz Eylul Univ, Ctr Fabricat & Applicat Elect Mat, TR-35390 Izmir, Turkiye
关键词
MMT; MOF; mu-dSPE; Antibiotics; HPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANTIBIOTIC-RESIDUES; WATER; SORBENT; MICROEXTRACTION; SAMPLES; MONTMORILLONITE; ADSORPTION; AMPICILLIN; POLYMER;
D O I
10.1016/j.microc.2022.108165
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, composite as a copper-containing metal-organic framework with montmorillonite (MMT) clay was synthesized and applied as an adsorbent for micro-dispersive solid-phase extraction (mu-dSPE) of sulfonamides (SAs) and penicillins (PENs). The synthesized composites including different content of MMT were characterized by Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, Brunauer-Emmett-Teller surface area, and thermogravimetric analysis. The determination of antibiotics was performed by high-performance liquid chromatography/diode array detection (HPLC/DAD) using C18 column as stationary phase, 0.1 % trifluoroacetic acid in water, and acetonitrile as mobile phase in gradient mode and detection at 270 nm for SAs and 230 nm for PENs. The as-synthesized composites were examined for their adsorption ability towards target antibiotics. The optimized parameter conditions were 10 mg of adsorbent, 5 mL of sample solution at pH 4, 10 min stirring by vortex, 1 mL of acetonitrile:methanol (1:1) as eluent solvent, and 5 min as elution time. Under optimized conditions, the proposed method presented good linearity from 0.5 to 400 mu g/L for SAs and from 1 to 400 mu g/L for PENs with coefficients of determination (r(2)) >= 0.9947, low limit of detections from 0.10 to 0.15 mu g/L for SAs and 0.30 to 1.50 mu g/L for PENs, acceptable repeatabilities less than 3.26 % for both groups and good recoveries from 82.3 % to 116.4 % with relative standard deviations less than 3.9 % for both groups in the spiked milk samples and synthetic urine solution. The developed mu-dSPE method following HPLC/DAD has been successfully applied to the determination of SAs and PENs milk samples and synthetic urine solutions.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Amino group functionalized metal-organic framework as dispersive solid-phase extraction sorbent to determine nitrobenzene compounds in water samples
    Dou, Yanan
    Guo, Lan
    Li, Guoliang
    Lv, Xiaoxia
    Xia, Lian
    JinmaoYou
    MICROCHEMICAL JOURNAL, 2019, 146 : 366 - 373
  • [32] A Zr(IV)-based porphyrinic metal-organic framework as a solid-phase sorbent for extraction of sulfonamides prior to their quantitation by LC-MS
    Deng, Ze-Hui
    Xu, Gui-Ju
    Wang, Xiao-Li
    Wang, Xia
    Wang, Ming-Lin
    Lin, Jin-Ming
    Zhao, Ru-Song
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [33] Fe3O4/reduced graphene oxide-carbon nanotubes composite for the magnetic solid-phase extraction and HPLC determination of sulfonamides in milk
    Feng, Yingying
    Hu, Xiaopeng
    Zhao, Faqiong
    Zeng, Baizhao
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (05) : 1058 - 1066
  • [34] A Zr(IV)-based porphyrinic metal-organic framework as a solid-phase sorbent for extraction of sulfonamides prior to their quantitation by LC-MS
    Ze-Hui Deng
    Gui-Ju Xu
    Xiao-Li Wang
    Xia Wang
    Ming-Lin Wang
    Jin-Ming Lin
    Ru-Song Zhao
    Microchimica Acta, 2018, 185
  • [35] Microcrystalline cellulose/metal-organic framework hybrid as a sorbent for dispersive micro-solid phase extraction of chlorophenols in water samples
    Ghaemi, Ferial
    Amiri, Amirhassan
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1626
  • [36] Metal organic frameworks (MOFs) for magnetic solid-phase extraction of pyrazole/pyrrole pesticides in environmental water samples followed by HPLC-DAD determination
    Ma, Jiping
    Yao, Zhidan
    Hou, Liwei
    Lu, Wenhui
    Yang, Qipeng
    Li, Jinhua
    Chen, Lingxin
    TALANTA, 2016, 161 : 686 - 692
  • [37] Nontargeted Screening and Determination of Sulfonamides: A Dispersive Micro Solid-Phase Extraction Approach to the Analysis of Milk and Honey Samples Using Liquid Chromatography-High-Resolution Mass Spectrometry
    Hu, Shuping
    Zhao, Min
    Xi, Yiyuan
    Mao, Qigi
    Zhou, Xudong
    Chen, Dawei
    Yan, Pengcheng
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (09) : 1984 - 1991
  • [38] Determination of sulfonamide residues in animal foodstuffs by magnetic dispersive solid-phase extraction using magnetic carbon nanocomposites coupled with ion pair-dispersive liquid–liquid micro-extraction combined with HPLC-DAD
    Najmeh Yazdanfar
    Mojtaba Shamsipur
    Mahnaz Ghambarian
    Journal of the Iranian Chemical Society, 2021, 18 : 1433 - 1442
  • [39] Fabrication of a magnetic metal-organic framework/covalent organic framework composite for simultaneous magnetic solid-phase extraction of seventeen trace quinolones residues in meats
    Lin, Shumin
    Liang, Bolong
    Zhao, Zhe
    Li, Zhenqiu
    Deng, Kai
    He, Hongbin
    Liang, Shu-xuan
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1709
  • [40] Application of bio-metal-organic framework-based magnetic dispersive solid phase extraction for the extraction of polycyclic aromatic hydrocarbons from pasteurized milk
    Mohebbi, Ali
    Fathi, Ali Akbar
    Mogaddam, Mohammad Reza Afshar
    Farajzadeh, Mir Ali
    Hashemi, Negin
    Alavian, Ali Sadeghi
    Fattahi, Nazir
    MICROCHEMICAL JOURNAL, 2023, 193