Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration

被引:3
|
作者
Ohashi, Toshio [1 ,2 ,6 ]
Naganawa, Shinji [3 ]
Nasu, Yusuke [2 ]
Kuno, Kayao [4 ]
Kato, Katsuhiko [5 ,7 ]
机构
[1] Nagoya Univ, Dept Integrated Hlth Sci, Grad Sch Med, Nagoya, Japan
[2] Kamiiida Daiichi Gen Hosp, Dept Radiol, Nagoya, Japan
[3] Nagoya Univ, Dept Radiol, Grad Sch Med, Nagoya, Japan
[4] Kamiiida Daiichi Gen Hosp, Dept Otorhinolaryngol, Nagoya, Japan
[5] Nagoya Univ, Grad Sch Med, Dept Integrated Hlth Sci,Biomed Imaging Sci, Div Adv Informat Hlth Sci,Funct Med Imaging, Nagoya, Japan
[6] Kamiiida Daiichi Gen Hosp, Dept Radiol, 2 70 Kamiiida kitamachi, Kita ku, Nagoya 4620802, Japan
[7] Nagoya Univ, Dept Integrated Hlth Sci, Div Adv Informat Hlth Sci, Funct Med Imaging,Biomed Imaging Sci,Grad Sch Med, 1 1 20 Daiko minami, Higashi ku, Nagoya 4618673, Japan
来源
NAGOYA JOURNAL OF MEDICAL SCIENCE | 2023年 / 85卷 / 02期
关键词
magnetic resonance imaging; gadolinium; endolymphatic hydrops; Meniere's disease; INNER-EAR; 3D-FLAIR; MRI; INJECTION; DISEASE;
D O I
10.18999/nagjms.85.2.299
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In the evaluation of endolymphatic hydrops (EH) using magnetic resonance (MR) imaging, hybrid of reversed image of positive endolymph signal and native image of perilymph signal multiplied with heav-ily T2-weighted MR cisternography (HYDROPS-Mi2) imaging with the intravenous administration of a gadolinium-based contrast agent (IV-GBCA) has been utilized. Recently, MR cisternography (MRC) without GBCA has been proposed as a potential alternative method. However, the feasibility of EH evaluation by MRC without GBCA has not been established. The present study aimed to compare HYDROPS-Mi2 imaging with IV-GBCA to MRC without IV-GBCA for the evaluation of EH. In 40 ears of 20 patients with clinically suspected EH, MRC at pre-IV-GBCA and HYDROPS-Mi2 images from 4 h post-IV-GBCA were analyzed. The saccular height on the MRC (SH-MRC) was measured. The percentage of the volume of the endolymphatic space within the whole lymphatic space of the vestibule on the HYDROPS-Mi2 image (%ELvolume-HYD) was measured. The correlation between the SH-MRC and %ELvolume-HYD was calculated. The receiver operating characteristic (ROC) of the SH-MRC and %ELvolume-HYD for the clinical diagnosis of EH was evaluated. The Spearman's rank correlation coefficient between the SH-MRC and %ELvolume-HYD was 0.102. The areas under the ROC curve were 0.570 for the SH-MRC, and 0.926 for the %ELvolume-HYD. In conclusion, there was no significant correlation between the MRC without IV-GBCA and the HYDOROPS-Mi2 with IV-GBCA in the evaluation of EH.
引用
收藏
页码:299 / 309
页数:11
相关论文
共 50 条
  • [31] Longitudinal Assessment of Endolymphatic Hydrops With Contrast-Enhanced Magnetic Resonance Imaging of the Labyrinth
    Jerin, Claudia
    Krause, Eike
    Ertl-Wagner, Birgit
    Guerkov, Robert
    OTOLOGY & NEUROTOLOGY, 2014, 35 (05) : 880 - 883
  • [32] Renal safety of gadolinium-based contrast agent for ionizing radiation imaging
    Becker, Joshua
    Thompson, Henrik
    RADIOLOGY, 2006, 240 (01) : 301 - 302
  • [33] Gadolinium-based Imaging Contrast Agents
    Milic, Natasa
    Preradovic, Nikolina
    Milosevic, Natasa
    Cirilovic, Viktorija Vucaj
    Till, Viktor
    CURRENT MEDICAL IMAGING REVIEWS, 2014, 10 (02) : 140 - 150
  • [34] Reliability of Magnetic Resonance Imaging Performed After Intratympanic Administration of Gadolinium in the Identification of Endolymphatic Hydrops in Patients With Meniere's Disease
    Fiorino, Francesco
    Pizzini, Francesca B.
    Beltramello, Alberto
    Mattellini, Barbara
    Barbieri, Franco
    OTOLOGY & NEUROTOLOGY, 2011, 32 (03) : 472 - 477
  • [35] Determination of gadolinium-based magnetic resonance imaging contrast agents by micellar electrokinetic capillary chromatography
    Andrasi, Melinda
    Gaspar, Attila
    Kovacs, Otilia
    Baranyai, Zsolt
    Klekner, Almos
    Bruecher, Erno
    ELECTROPHORESIS, 2011, 32 (16) : 2223 - 2228
  • [36] Grading of endolymphatic hydrops using magnetic resonance imaging
    Nakashima, Tsutomu
    Naganawa, Shinji
    Pyykko, Ilmari
    Gibson, William P. R.
    Sone, Michihiko
    Nakata, Seiichi
    Teranishi, Masaaki
    ACTA OTO-LARYNGOLOGICA, 2009, 129 : 5 - 8
  • [37] Diagnosis of endolymphatic hydrops in vivo with magnetic resonance imaging
    Niyazov, DM
    Andrews, JC
    Strelioff, D
    Sinha, S
    Lufkin, R
    OTOLOGY & NEUROTOLOGY, 2001, 22 (06) : 813 - 817
  • [38] Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
    Frenzel, Thomas
    Lengsfeld, Philipp
    Schirmer, Heiko
    Huetter, Joachim
    Weinmann, Hanns-Joachim
    INVESTIGATIVE RADIOLOGY, 2008, 43 (12) : 817 - 828
  • [39] Do we need gadolinium-based contrast medium for brain magnetic resonance imaging in children?
    Dennis Dünger
    Matthias Krause
    Daniel Gräfe
    Andreas Merkenschlager
    Christian Roth
    Ina Sorge
    Pediatric Radiology, 2018, 48 : 858 - 864
  • [40] Do we need gadolinium-based contrast medium for brain magnetic resonance imaging in children?
    Duenger, Dennis
    Krause, Matthias
    Graefe, Daniel
    Merkenschlager, Andreas
    Roth, Christian
    Sorge, Ina