Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration

被引:3
|
作者
Ohashi, Toshio [1 ,2 ,6 ]
Naganawa, Shinji [3 ]
Nasu, Yusuke [2 ]
Kuno, Kayao [4 ]
Kato, Katsuhiko [5 ,7 ]
机构
[1] Nagoya Univ, Dept Integrated Hlth Sci, Grad Sch Med, Nagoya, Japan
[2] Kamiiida Daiichi Gen Hosp, Dept Radiol, Nagoya, Japan
[3] Nagoya Univ, Dept Radiol, Grad Sch Med, Nagoya, Japan
[4] Kamiiida Daiichi Gen Hosp, Dept Otorhinolaryngol, Nagoya, Japan
[5] Nagoya Univ, Grad Sch Med, Dept Integrated Hlth Sci,Biomed Imaging Sci, Div Adv Informat Hlth Sci,Funct Med Imaging, Nagoya, Japan
[6] Kamiiida Daiichi Gen Hosp, Dept Radiol, 2 70 Kamiiida kitamachi, Kita ku, Nagoya 4620802, Japan
[7] Nagoya Univ, Dept Integrated Hlth Sci, Div Adv Informat Hlth Sci, Funct Med Imaging,Biomed Imaging Sci,Grad Sch Med, 1 1 20 Daiko minami, Higashi ku, Nagoya 4618673, Japan
来源
NAGOYA JOURNAL OF MEDICAL SCIENCE | 2023年 / 85卷 / 02期
关键词
magnetic resonance imaging; gadolinium; endolymphatic hydrops; Meniere's disease; INNER-EAR; 3D-FLAIR; MRI; INJECTION; DISEASE;
D O I
10.18999/nagjms.85.2.299
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In the evaluation of endolymphatic hydrops (EH) using magnetic resonance (MR) imaging, hybrid of reversed image of positive endolymph signal and native image of perilymph signal multiplied with heav-ily T2-weighted MR cisternography (HYDROPS-Mi2) imaging with the intravenous administration of a gadolinium-based contrast agent (IV-GBCA) has been utilized. Recently, MR cisternography (MRC) without GBCA has been proposed as a potential alternative method. However, the feasibility of EH evaluation by MRC without GBCA has not been established. The present study aimed to compare HYDROPS-Mi2 imaging with IV-GBCA to MRC without IV-GBCA for the evaluation of EH. In 40 ears of 20 patients with clinically suspected EH, MRC at pre-IV-GBCA and HYDROPS-Mi2 images from 4 h post-IV-GBCA were analyzed. The saccular height on the MRC (SH-MRC) was measured. The percentage of the volume of the endolymphatic space within the whole lymphatic space of the vestibule on the HYDROPS-Mi2 image (%ELvolume-HYD) was measured. The correlation between the SH-MRC and %ELvolume-HYD was calculated. The receiver operating characteristic (ROC) of the SH-MRC and %ELvolume-HYD for the clinical diagnosis of EH was evaluated. The Spearman's rank correlation coefficient between the SH-MRC and %ELvolume-HYD was 0.102. The areas under the ROC curve were 0.570 for the SH-MRC, and 0.926 for the %ELvolume-HYD. In conclusion, there was no significant correlation between the MRC without IV-GBCA and the HYDOROPS-Mi2 with IV-GBCA in the evaluation of EH.
引用
收藏
页码:299 / 309
页数:11
相关论文
共 50 条
  • [21] Cellular toxicities of gadolinium-based contrast agents used in magnetic resonance imaging
    Akbas, Ece
    Unal, Fatma
    Yuzbasioglu, Deniz
    JOURNAL OF APPLIED TOXICOLOGY, 2023, 43 (07) : 958 - 972
  • [22] High-resolution magnetic resonance imaging using gadolinium-based contrast agent for atherosclerotic carotid plaque
    Kawahara, Ichiro
    Morikawa, Minoru
    Honda, Masaru
    Kitagawa, Naoki
    Tsutsumi, Keisuke
    Nagata, Izumi
    Hayashi, Tomayoshi
    Koji, Takehiko
    SURGICAL NEUROLOGY, 2007, 68 (01): : 60 - 66
  • [23] Evaluation of signal intensity changes in dentate nucleus and globus pallidus on magnetic resonance imaging after intrathecal gadolinium-based contrast agent administration
    Asoglu, Semih
    Kilincer, Abidin
    Ozer, Halil
    Topaloglu, Omer Faruk
    Cebeci, Hakan
    CLINICAL IMAGING, 2024, 109
  • [24] The effect of a gadolinium-based contrast agent on diffusion tensor imaging
    Zolal, Amir
    Sames, Martin
    Burian, Martin
    Novakova, Martina
    Malucelli, Alberto
    Hejcl, Ales
    Bartos, Robert
    Vachata, Petr
    Derner, Milous
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : 1877 - 1882
  • [25] Comparison of different analytical methods for speciation of seven gadolinium-based magnetic resonance imaging contrast agents and the applications in wastewater and whole blood
    Feng, Shunqing
    Shen, Suyun
    Yao, Yao
    Liang, Minsi
    Chen, Yunxin
    Liu, Hongtao
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (04)
  • [26] Gadolinium-Based Magnetic Resonance Contrast Agents for Neuroradiology: An Overview
    Kanal, Emanuel
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 625 - +
  • [27] Gadolinium-Based Contrast Agents for Vessel Wall Magnetic Resonance Imaging (MRI) of Atherosclerosis
    Calcagno C.
    Ramachandran S.
    Millon A.
    Robson P.M.
    Mani V.
    Fayad Z.
    Current Cardiovascular Imaging Reports, 2013, 6 (1) : 11 - 24
  • [28] Effect of IV Administration of a Gadolinium-Based Contrast Agent on Breast Diffusion-Tensor Imaging
    Scaranelo, Anabel M.
    Degani, Hadassa
    Grobgeld, Dov
    Talbot, Nancy
    Bodolai, Karen
    Furman-Haran, Edna
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (04) : 1030 - 1036
  • [29] Neurologic Effects of Gadolinium Retention in the Brain after Gadolinium-based Contrast Agent Administration
    Ayers-Ringler, Jennifer
    McDonald, Jennifer S.
    Connors, Margaret A.
    Fisher, Cody R.
    Han, Susie
    Jakaitis, Daniel R.
    Scherer, Bradley
    Tutor, Gabriel
    Wininger, Katheryn M.
    Dai, Daying
    Choi, Doo-Sup
    Salisbury, Jeffrey L.
    Jannetto, Paul J.
    Bornhorst, Joshua A.
    Kadirvel, Ram
    Kallmes, David F.
    McDonald, Robert J.
    RADIOLOGY, 2022, 302 (03) : 676 - 683
  • [30] Caspase-responsive smart gadolinium-based contrast agent for magnetic resonance imaging of drug-induced apoptosis
    Ye, Deju
    Shuhendler, Adam J.
    Pandit, Prachi
    Brewer, Kimberly D.
    Tee, Sui Seng
    Cui, Lina
    Tikhomirov, Grigory
    Rutt, Brian
    Rao, Jianghong
    CHEMICAL SCIENCE, 2014, 5 (10) : 3845 - 3852