Performance Comparison of Cables With Partial Transposition

被引:0
|
作者
Frittitta, Chiara [1 ]
Bruzzone, Pierluigi [1 ]
Bajas, Hugues [1 ]
Dematte, Federica [1 ]
Sedlak, Kamil [1 ]
机构
[1] PSI, EPFL SPC, CH-5232 Villigen, Switzerland
关键词
Conductors; Power cables; Inductance; Superconducting cables; Voltage; Resistance; Copper; Cable transposition; current distribution; fusion magnets;
D O I
10.1109/TASC.2024.3367804
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The need of full transposition of the current carrying elements (strands) in large cables is frequently retained as top design criterion for conductors operating in pulsed mode. However, when the transposition error, i.e., the inductance difference among the strands, is small and the inter-strand resistance is low, the criterion can be relaxed for a certain range of operating conditions. In this work, two partly transposed cables made of 18 Nb3Sn strands and one copper core (cu +6 + 12) and 19 Nb3Sn strands (1 + 6 + 12) are assembled in a SULTAN sample and tested under various operating conditions. No significant performance difference is observed, i.e., the 19 strands cable has slightly higher current sharing temperature, T-cs, than the 18 strands cable, as predictable from the superconductor cross section. The inductance imbalance in the 1 + 6 + 12 cable does not lead to either instability or performance loss. The test results support the soundness of the conductor layout of EUROfusion DEMO, where the 19 strands assembly is used as the first cable stage of the react & wind conductor.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [31] Rejuvenation Addresses Partial Discharge in Power Cables
    Bertini, Glen J.
    Chy, Hunly
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (02) : 688 - 696
  • [32] Partial Discharges Monitoring System in Transformers and Cables
    Magrini, Luiz Carlos
    Kayano, Paula S. D.
    Ogiboski, Luciano
    Goncalves, Francisco Andre, Jr.
    2013 IEEE PES CONFERENCE ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT LATIN AMERICA), 2013,
  • [33] On Line Partial Discharge Diagnosis of Power Cables
    Montanari, G. C.
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 210 - 215
  • [34] On-line partial discharge detection in cables
    Ahmed, NH
    Srinivas, NN
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1998, 5 (02) : 181 - 188
  • [35] Bounds on quantum nonlocality via partial transposition
    Horodecki, Karol
    Murta, Glaucia
    PHYSICAL REVIEW A, 2015, 92 (01):
  • [36] PARTIAL TRANSPOSITION AND NON-EXTENDIBLE MAPS
    KRUSZYNSKI, P
    WORONOWICZ, SL
    LETTERS IN MATHEMATICAL PHYSICS, 1979, 3 (04) : 319 - 324
  • [37] PERFORMANCE COMPARISON OF RECEIVERS IN A SIMPLE PARTIAL ERASURE MODEL
    LEE, I
    YAMAUCHI, T
    CIOFFI, JM
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (04) : 1465 - 1469
  • [38] The fire performance of PVC cables standard cables and newer developments
    Sander, M
    EUROCABLE, 2000, : 142 - 150
  • [39] Performance Comparison of PD Data Acquisition Techniques for Condition Monitoring of Medium Voltage Cables
    Shafiq, Muhammad
    Kiitam, Ivar
    Kauhaniemi, Kimmo
    Taklaja, Paul
    Kutt, Lauri
    Palu, Ivo
    ENERGIES, 2020, 13 (16)
  • [40] IMPROVED FIRE PERFORMANCE CABLES
    PHILBRICK, SE
    BENNETT, HR
    ELECTRICAL REVIEW, 1975, 197 (04): : 119 - 121