Performance Comparison of Cables With Partial Transposition

被引:0
|
作者
Frittitta, Chiara [1 ]
Bruzzone, Pierluigi [1 ]
Bajas, Hugues [1 ]
Dematte, Federica [1 ]
Sedlak, Kamil [1 ]
机构
[1] PSI, EPFL SPC, CH-5232 Villigen, Switzerland
关键词
Conductors; Power cables; Inductance; Superconducting cables; Voltage; Resistance; Copper; Cable transposition; current distribution; fusion magnets;
D O I
10.1109/TASC.2024.3367804
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The need of full transposition of the current carrying elements (strands) in large cables is frequently retained as top design criterion for conductors operating in pulsed mode. However, when the transposition error, i.e., the inductance difference among the strands, is small and the inter-strand resistance is low, the criterion can be relaxed for a certain range of operating conditions. In this work, two partly transposed cables made of 18 Nb3Sn strands and one copper core (cu +6 + 12) and 19 Nb3Sn strands (1 + 6 + 12) are assembled in a SULTAN sample and tested under various operating conditions. No significant performance difference is observed, i.e., the 19 strands cable has slightly higher current sharing temperature, T-cs, than the 18 strands cable, as predictable from the superconductor cross section. The inductance imbalance in the 1 + 6 + 12 cable does not lead to either instability or performance loss. The test results support the soundness of the conductor layout of EUROfusion DEMO, where the 19 strands assembly is used as the first cable stage of the react & wind conductor.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] Partial discharge monitoring in medium voltage cables
    Zhou, Chengke
    Hepburn, Donald M.
    Michel, Mattheiu
    Song, Xiaodi
    Zhang, Guobin
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1021 - +
  • [22] Methods for Partial Discharge Testing of Aerospace Cables
    Christou, Ilias
    Cotton, Ian
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [23] Charge Concept in Partial Discharge in Power Cables
    Mandipour, Mandi
    Akbari, Asghar
    Werle, Peter
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) : 817 - 825
  • [24] Comparison of Total Arch and Partial Arch Transposition During Hybrid Endovascular Repair for Aortic Arch Disease
    Kang, W. C.
    Ko, Y. -G.
    Oh, P. C.
    Shin, E. K.
    Park, C. -H.
    Choi, D.
    Youn, Y. N.
    Lee, D. Y.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 52 (02) : 173 - 178
  • [25] DIGITAL LOCATION OF PARTIAL DISCHARGES IN HV CABLES
    BORSI, H
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (01): : 28 - 36
  • [26] IMPROVEMENT IN THE INSTRUMENTATION FOR PARTIAL DISCHARGE LOCATION IN CABLES
    WEEKS, WL
    STEINER, JP
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (04): : 754 - 760
  • [27] On-line partial discharge detection in cables
    Ahmed, NH
    Srinivas, NN
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 214 - 217
  • [28] PARTIAL DISCHARGE MEASUREMENTS ON POWER CABLES.
    Jenni, A.
    Wire Industry, 1982, 49 (585): : 723 - 726
  • [29] Energy dissipation by partial discharge in cryogenic cables
    Sauers, I
    Pace, MO
    James, DR
    Ellis, AR
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 624 - 627
  • [30] Monitoring of Partial Discharges in HVDC Power Cables
    Winkelmann, Erik
    Shevchenko, Iaroslav
    Steiner, Christoph
    Kleiner, Christian
    Kaltenborn, Uwe
    Birkholz, Peter
    Schwarz, Harald
    Steiner, Thomas
    IEEE ELECTRICAL INSULATION MAGAZINE, 2022, 38 (01) : 7 - 18