Performance Comparison of Cables With Partial Transposition

被引:0
|
作者
Frittitta, Chiara [1 ]
Bruzzone, Pierluigi [1 ]
Bajas, Hugues [1 ]
Dematte, Federica [1 ]
Sedlak, Kamil [1 ]
机构
[1] PSI, EPFL SPC, CH-5232 Villigen, Switzerland
关键词
Conductors; Power cables; Inductance; Superconducting cables; Voltage; Resistance; Copper; Cable transposition; current distribution; fusion magnets;
D O I
10.1109/TASC.2024.3367804
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The need of full transposition of the current carrying elements (strands) in large cables is frequently retained as top design criterion for conductors operating in pulsed mode. However, when the transposition error, i.e., the inductance difference among the strands, is small and the inter-strand resistance is low, the criterion can be relaxed for a certain range of operating conditions. In this work, two partly transposed cables made of 18 Nb3Sn strands and one copper core (cu +6 + 12) and 19 Nb3Sn strands (1 + 6 + 12) are assembled in a SULTAN sample and tested under various operating conditions. No significant performance difference is observed, i.e., the 19 strands cable has slightly higher current sharing temperature, T-cs, than the 18 strands cable, as predictable from the superconductor cross section. The inductance imbalance in the 1 + 6 + 12 cable does not lead to either instability or performance loss. The test results support the soundness of the conductor layout of EUROfusion DEMO, where the 19 strands assembly is used as the first cable stage of the react & wind conductor.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [1] Potential performance of partial crosstalk cancellation in twisted pair cables
    Holte, Nils
    GLOBECOM 2006 - 2006 IEEE GLOBAL TELECOMMUNICATIONS CONFERENCE, 2006,
  • [2] PARTIAL TRANSPOSITION COMPLEXES
    LEV, M
    ECKNER, FAO
    MENG, CCL
    RIMOLDI, HJA
    AMERICAN JOURNAL OF CARDIOLOGY, 1965, 15 (01): : 136 - &
  • [3] Comparison of the Performance Of Sparsely Screened and Coaxial HV Cables
    Woodhouse, Darren
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2012,
  • [4] Comparison of parametric Partial Discharge and Dissipation Factor Characteristics of MV PILC Cables
    Mladenovic, I.
    Weindl, Ch.
    Freitag, Ch.
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 319 - 322
  • [5] A Comparison of Double-End Partial Discharge Localization Algorithms in Power Cables
    Abu Bakar, Asfarina
    Yii, Chai Chang
    Fern, Chin Kui
    Hou Pin, Yoong
    Lago, Herwansyah
    Rohani, Mohamad Nur Khairul Hafizi
    ENERGIES, 2023, 16 (04)
  • [6] Comparison of arrival time estimation methods for partial discharge pulses in power cables
    Wagenaars, Paul
    Wouters, Peter A. A. F.
    van der Wielen, Peter C. J. M.
    Steennis, E. Fred
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1162 - +
  • [7] Partial transposition on bipartite system
    Ren Xi-Jun
    Han Yong-Jian
    Wu Yu-Chun
    Guo Guang-Can
    CHINESE PHYSICS LETTERS, 2008, 25 (01) : 35 - 38
  • [8] Partial closure of transposition flap
    Kuwahara, RT
    Juracek, L
    DERMATOLOGIC SURGERY, 2000, 26 (11) : 1081 - 1081
  • [9] PARTIAL TRANSPOSITION OF LARGE VESSELS
    BREINING, H
    ZEITSCHRIFT FUR KREISLAUFFORSCHUNG, 1971, 60 (02): : 151 - &
  • [10] Comparison of Different Voltage Waveforms for Partial Discharge Measurement in Medium Voltage Cables and Accessories
    Jahromi, Ali Naderian
    Pattabi, Pranav Ketharam
    Lo, Shanon
    Densley, John
    2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 5 - 8