Totally Implantable Oxygen Generator (TIOG) for Hypoxia and Hypoxemia

被引:1
|
作者
Islam, Sayemul [1 ]
Huggins, Rebecca C. [1 ]
Almeseri, Abdulaziz N. A. E. [2 ]
Domic, Michael [2 ]
Song, Seung Hyun [3 ]
Polizzotti, Brian D. [4 ]
Kim, Albert [5 ,6 ]
机构
[1] Univ S Florida, Dept Med Engn, Tampa, FL USA
[2] Temple Univ, Elect & Comp Engn Dept, Philadelphia, PA USA
[3] SookMyung Womens Univ, Dept Elect Engn, Seoul, South Korea
[4] Boston Childrens Hosp, Dept Cardiol, Boston, MA USA
[5] Temple Univ, Tampa, FL 33606 USA
[6] Univ S Florida, Dept Med Engn, Tampa, FL 33620 USA
基金
美国国家科学基金会;
关键词
Low-power electronics; biomedical electronics; oxygen; implants; biomedical electrodes; biomedical transducers; biomedical telemetry; ELECTROLYSIS; MECHANISMS; DELIVERY; THERAPY; WATER;
D O I
10.1109/TBME.2022.3217164
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hypoxia and hypoxemia are the conditions when oxygen is depleted from the cell due to, for example, respiratory failure, cancer, etc. While the current therapy brought reasonable clinical outcomes, its systematic nature of oxygen delivery can be compromised by a significant dropout and side effects. This paper presents a totally implantable oxygen generator (TIOG) for localized, highly controllable, real-time, and targeted oxygen delivery. Methods: The TIOG system, an ultra-low power implantable wireless platform, is built using off-the-shelf components. The TIOG can be remotely operated to enable a tailored oxygen delivery based on electrolysis with a precisely controlled electrical signal (i.e., current level, frequency, and duty cycle). Results: The in vitro experiments demonstrate that the TIOG could deliver oxygen with a rate of 9.27 +/- 1.9 mu mol/L/min with the pulsed electrical current (800 mu A, 600 mu s pulse or 6% duty cycle with 10 ms period). The system could also suppress chlorine generation under the safety guideline (5 mg/L). Operating at 433 MHz ISM band, the TIOG could be wirelessly controlled from up to 600 cm distance with a 0%-bit error rate (BER) and 0%-packet error rate (PER). A single charge of the battery could operate the system for up to 3.3 hr, which can be wirelessly recharged for long-term operation. Conclusion: The longevity of the TIOG system enables ambulatory oxygen therapy in a much longer-term than current practice.
引用
收藏
页码:1380 / 1388
页数:9
相关论文
共 50 条
  • [41] Evaluation of totally implantable catheters in healthy horses
    Adriana Fernandes de Souza Garcia
    Gesiane Ribeiro
    Julia de Assis Arantes
    Gustavo Morandini Reginato
    Nathalia Villaca Xavier
    Adriano Bonfim Carregaro
    Thiago Jhonatha Fernandes Silva
    Renan Grigoletto
    Silvio Henrique de Freitas
    Renata Gebara Sampaio Dória
    BMC Veterinary Research, 17
  • [42] IS A TOTALLY IMPLANTABLE ARTIFICIAL-HEART REALISTIC
    NOSE, Y
    ARTIFICIAL ORGANS, 1992, 16 (01) : 19 - 42
  • [43] IMPLANTABLE DEFIBRILLATOR GENERATOR MIGRATION
    DOUGHERTY, AH
    WOLBRETTE, D
    CIRCULATION, 1994, 90 (03) : 1557 - 1557
  • [44] OXYGEN CONSUMPTION AFTER OXYGEN THERAPY FOR HYPOXEMIA
    GROVES, AC
    DUFF, JH
    LAPOINTE, R
    MCLEAN, APH
    MACLEAN, LD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (06): : 842 - &
  • [45] Malfunction of implantable pulse generator
    Apetauerova, D.
    Zani, J.
    Arle, J.
    Shils, J.
    MOVEMENT DISORDERS, 2008, 23 (01) : S384 - S384
  • [46] Infected Implantable Pulse Generator
    Dujari, Shefali
    Gold, Carl A.
    NEUROHOSPITALIST, 2019, 9 (03): : 172 - 173
  • [47] Perinatal Hypoxemia and Oxygen Sensing
    Mouradian, Gary C., Jr.
    Lakshminrusimha, Satyan
    Konduri, Girija G.
    COMPREHENSIVE PHYSIOLOGY, 2021, 11 (02) : 1653 - 1677
  • [48] TREATMENT OF HYPOXEMIA WITH AN OXYGEN ENRICHER
    CHUSID, EL
    LIBROT, M
    UTZURRUM, F
    BICKERMAN, HA
    CHEST, 1979, 76 (03) : 278 - 282
  • [49] VENTILATORY ACCLIMATIZATION TO HYPOXIA IS NOT DEPENDENT ON ARTERIAL HYPOXEMIA
    BUSCH, MA
    BISGARD, GE
    FORSTER, HV
    JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (06) : 1874 - 1880
  • [50] HYPOXEMIA, CELLULAR HYPOXIA, AND THE OXYHEMOGLOBIN DISSOCIATION CURVE
    ANDERSEN, PT
    NIELSEN, LK
    MOLGAARD, J