Preparation and characterization of glucose-based covalent organic polymer coated silica as stationary phase for high-performance liquid chromatography

被引:3
|
作者
Gao, Li [1 ]
Wang, Yuan [1 ]
Qin, Yaqiong [2 ]
Sun, Yaming [1 ]
He, Lijun [1 ]
Zhang, Shusheng [3 ]
Zhao, Wenjie [1 ]
机构
[1] Henan Univ Technol, Sch Chem & Chem Engn, Zhengzhou 450001, Peoples R China
[2] Zhengzhou Tobacco Res Inst CNTC, Zhengzhou 450008, Peoples R China
[3] Zhengzhou Univ, Ctr Modern Anal & Gene Sequencing, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
Tetrabenzylglucose-based covalent organic; polymer; Solvent kitting reaction; Core -shell material; Reversed-phase; hydrophilic interaction; mixed; -mode; Chromatographic separation;
D O I
10.1016/j.chroma.2023.463876
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Carbohydrate is a renewable, sustainable, hydrophilic, and biodegradable natural product, which is widely used in the field of adsorption. In this study, a glucose-based covalent organic polymer (COP) coated silica was fabricated by facile solvent knitting reaction between tetrabenzylglucose and silica-phenyl with anhydrous aluminum trichloride as catalyst, forming a core-shell stationary phase (donated as SiO2 @COPBn-glu) for high performance liquid chromatography. The prepared SiO2 @COPBn-glu was charac-terized by scanning electron microscopy, transmission electron microscopy, Fourier-transform infrared spectrometry, solid-state 13 C nuclear magnetic resonance spectrometry, X-ray photoelectron spectroscopy, and N 2 adsorption-desorption experiments. Owing to the coexistence of benzene units and alkyl, hy-droxyl and ether groups in the skeleton of COPBn-glu shell, the developed chromatographic packing ex-hibited reversed-phase/hydrophilic interaction mixed-mode with multiple retention mechanisms, such as hydrophobic, pi-pi, hydrogen bonding, and electron donor-acceptor interactions. The results revealed that the SiO2 @COPBn-glu column demonstrated excellent selectivity and retention behavior for both hydrophilic and hydrophobic compounds with good repeatability and stability. Meanwhile, the chromatographic per-formance of the prepared SiO2 @COPBn-glu column was compared with a C 18 column to assess the role of the coating COPBn-glu shell. Therefore, the development of the SiO2 @COPBn-glu stationary phase expands the potential application of COPs in separation field.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Phenylaminopropyl silica - a new specific stationary phase for high-performance liquid chromatography of phenols
    Kiseleva, MG
    Nesterenko, PN
    JOURNAL OF CHROMATOGRAPHY A, 2000, 898 (01) : 23 - 34
  • [22] Glucose-based carbon dots-modified silica stationary phase for hydrophilic interaction chromatography
    Yuan, Ning
    Chen, Jia
    Cai, Tianpei
    Li, Zhan
    Guan, Ming
    Zhao, Liang
    Qiu, Hongdeng
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1619
  • [23] High efficiency and simple preparation of polyacrylamide coated silica stationary phase for hydrophilic interaction liquid chromatography
    Wang, Yuhuan
    Bu, Hai
    Wang, Lei
    Wang, Licheng
    Guo, Yong
    Liang, Xiaojing
    Wang, Shuai
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1605
  • [24] Preparation and characterization of a new p-allylealix[4]arene-bonded silica gel stationary phase for high-performance liquid chromatography
    Li, WZ
    Wang, X
    Dou, JM
    Ma, CL
    Chen, LR
    Li, YM
    ACTA CHIMICA SINICA, 2004, 62 (04) : 405 - 409
  • [25] Quinolinium ionic liquid-modified silica as a novel stationary phase for high-performance liquid chromatography
    Min Sun
    Juanjuan Feng
    Chuannan Luo
    Xia Liu
    Shengxiang Jiang
    Analytical and Bioanalytical Chemistry, 2014, 406 : 2651 - 2658
  • [26] Quinolinium ionic liquid-modified silica as a novel stationary phase for high-performance liquid chromatography
    Sun, Min
    Feng, Juanjuan
    Luo, Chuannan
    Liu, Xia
    Jiang, Shengxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (11) : 2651 - 2658
  • [27] Polymer-silica hybrids: Evaluation of grafted poly(acrylonitrile) as organic phase for high-performance liquid chromatography
    Ihara, H
    Okazaki, S
    Ohmori, K
    Uemura, S
    Hirayama, C
    Nagaoka, S
    ANALYTICAL SCIENCES, 1998, 14 (02) : 349 - 354
  • [28] Polymer-Silica Hybrids: Evaluation of Grafted Poly(acrylonitrile) as Organic Phase for High-Performance Liquid Chromatography
    Hirotaka Ihara
    Shinya Okazaki
    Kanako Ohmori
    Shinobu Uemura
    Chuichi Hirayama
    Shoji Nagaoka
    Analytical Sciences, 1998, 14 : 349 - 354
  • [29] Preparation of a silica-based high-performance hydrophobic interaction chromatography stationary phase for protein separation and renaturation
    Yang, Yicong
    Qu, Qian
    Li, Weimin
    Yuan, Jie
    Ren, Yi
    Wang, Lili
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (13) : 2481 - 2490
  • [30] Chiral high-performance liquid chromatography with cellulose derivative stationary phases coated on underivatized silica gel
    Chen, XM
    Zou, HF
    Yang, L
    Wang, HL
    Zhang, Q
    AMERICAN LABORATORY, 2000, 32 (21) : 30 - 30