An audit of patient radiation doses in interventional radiology at a South African hospital

被引:1
|
作者
Slave, Oneile [1 ]
Mahomed, Nasreen [1 ]
机构
[1] Univ Witwatersrand, Fac Hlth Sci, Dept Radiol, Johannesburg, South Africa
来源
SA JOURNAL OF RADIOLOGY | 2023年 / 27卷 / 01期
关键词
Interventional radiology; diagnostic reference level; kerma air product; reference point air kerma; fluoroscopy time; DIAGNOSTIC REFERENCE LEVELS; MULTICENTER; EXPOSURE; IR;
D O I
10.4102/sajr.v27i1.2559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Interventional radiology (IR) is becoming more relevant in patient care and is associated with increased patient radiation exposure and radiation-induced adverse effects. Diagnostic reference levels (DRLs) are crucial for radiation control. There is a paucity of published DRLs for IR in South Africa and sub-Saharan Africa. Objectives: This study aimed to determine local DRLs for fluoroscopically-guided IR procedures and compare the achieved DRLs with published local and international DRLs. Method: Retrospective, descriptive, single-centre study. Kerma air product (KAP), reference point air kerma (Ka,r) and fluoroscopy time (FT) were collected for patients (12 years and older) who underwent IR procedures at a university hospital from 01 January 2019 to 31 December 2019. The 75th percentile of the distribution of each dose parameter (KAP, Ka,r and FT) per procedure was calculated and taken as the local diagnostic reference levels (LDRL). The established LDRLs were compared to published DRLs. Results: A total of 564 cases were evaluated. The 13 most frequent procedures (with 15 or more cases) represented 86.1% (487/564). Percutaneous transhepatic biliary drainage was the most common procedure (n = 146, 25.9%). Diagnostic cerebral angiogram DRLs exceeded the published DRL data ranges for all parameters (DRL 209.3), and interventional cerebral angiogram exceeded published ranges (DRL 275). Uterine artery embolisation (UAE) exceeded these ranges for KAP and Ka,r. (KAP-954.9 Gy/cm2, Ka,r-2640.8 mGy). Conclusion: The LDRLs for diagnostic cerebral angiogram, interventional cerebral angiogram and UAE exceeded published international DRL ranges. These procedures require radiation optimisation as recommended by the International Commission on Radiological Protection (ICRP). Contribution: In addition to informing radiation protection practices at the level of the institution, the established LDRLs contribute towards Regional and National DRLs.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Patient radiation doses and reference levels in pediatric interventional radiology
    Geryes, Bouchra Habib
    Bak, Adeline
    Lachaux, Julie
    Ozanne, Augustin
    Boddaert, Nathalie
    Brunelle, Francis
    Naggara, Olivier
    Saliou, Guillaume
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3983 - 3990
  • [2] Patient radiation doses and reference levels in pediatric interventional radiology
    Bouchra Habib Geryes
    Adeline Bak
    Julie Lachaux
    Augustin Ozanne
    Nathalie Boddaert
    Francis Brunelle
    Olivier Naggara
    Guillaume Saliou
    European Radiology, 2017, 27 : 3983 - 3990
  • [3] Occupational radiation doses in interventional radiology: Simulations
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 36 - 38
  • [4] The interdependence of staff and patient doses in interventional radiology
    Williams, JR
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (833): : 498 - 503
  • [5] Patient Radiation Doses in Interventional Radiology Procedures: Comparison of Fluoroscopy Dose Indices between the American College of Radiology Dose Index Registry-Fluoroscopy Pilot and the Radiation Doses in Interventional Radiology Study
    Jones, A. Kyle
    Wunderle, Kevin A.
    Fruscello, Tom
    Simanowith, Michael
    Cline, Brendan
    Dharmadhikari, Shalmali
    Duan, Xinhui
    Durack, Jeremy C.
    Hirschl, David
    Kim, Don-Soo
    Mahmood, Usman
    Mann, Steve D.
    Martin, Charles
    Metwalli, Zeyad
    Moirano, Jeffrey M.
    Neill, Rebecca A.
    Newsome, Janice
    Padua, Horacio
    Schoenfeld, Alan H.
    Miller, Donald L.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (04)
  • [6] Estimating Radiation Doses to the Skin from Interventional Radiology Procedures for a Patient Population with Cancer
    Dauer, Lawrence T.
    Thornton, Raymond
    Erdi, Yusuf
    Ching, Hung
    Hamacher, Klaus
    Boylan, Daniel C.
    Williamson, Matthew J.
    Balter, Stephen
    Germain, Jean St.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (06) : 782 - 788
  • [7] Staff radiation doses to the lower extremities in interventional radiology
    Shortt, C. P.
    Al-Hashimi, H.
    Malone, L.
    Lee, M. J.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (06) : 1206 - 1209
  • [8] Staff Radiation Doses to the Lower Extremities in Interventional Radiology
    C. P. Shortt
    H. Al-Hashimi
    L. Malone
    M. J. Lee
    CardioVascular and Interventional Radiology, 2007, 30 : 1206 - 1209
  • [9] Multi system comparison of patient doses in interventional radiology
    Bor, D
    Toklu, T
    Olgar, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1353 - 1353
  • [10] Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for US Practice
    Miller, Donald L.
    Kwon, Deukwoo
    Bonavia, Grant H.
    RADIOLOGY, 2009, 253 (03) : 753 - 764