Biomechanical properties of different anterior and posterior techniques for atlantoaxial fixation: a finite element analysis

被引:3
|
作者
Li, Jie [1 ]
Cao, Shuai [2 ]
Guo, Dong [1 ]
Lu, Teng [1 ]
Zang, Quanjin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Orthoped, 157Th West Fifth Rd, Xian 710004, Shaanxi, Peoples R China
[2] Civil Aviat Gen Hosp, Dept Orthoped, 1 Gaojing Stress, Beijing 100123, Peoples R China
关键词
Atlantoaxial fixation; Nonfixed segment degeneration; Segmental stability; Stress concentration; Finite element; TRANSARTICULAR SCREW FIXATION; CERVICAL-SPINE; DISLOCATION; REDUCTION; INSTABILITY; FUSION; TARP;
D O I
10.1186/s13018-023-03905-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundMany techniques for atlantoaxial fixation have been developed. However, the biomechanical differences among various atlantoaxial fixation methods remain unclear. This study aimed to evaluate the biomechanical influence of anterior and posterior atlantoaxial fixation techniques on fixed and nonfixed segments.MethodsAn occiput-C7 cervical finite element model was used to construct 6 surgical models including a Harms plate, a transoral atlantoaxial reduction plate (TARP), an anterior transarticular screw (ATS), a Magerl screw, a posterior screw-plate, and a screw-rod system. Range of motion (ROM), facet joint force (FJF), disc stress, screw stress, and bone-screw interface stress were calculated.ResultsThe C1/2 ROMs were relatively small in the ATS and Magerl screw models under all loading directions except for extension (0.1 & DEG;-1.0 & DEG;). The posterior screw-plate system and screw-rod system generated greater stresses on the screws (77.6-1018.1 MPa) and bone-screw interfaces (58.3-499.0 MPa). The Harms plate and TARP models had relatively small ROMs (3.2 & DEG;-17.6 & DEG;), disc stress (1.3-7.6 MPa), and FJF (3.3-106.8 N) at the nonfixed segments. Changes in disc stress and FJF of the cervical segments were not consistent with changes in ROM.ConclusionsATS and Magerl screws may provide good atlantoaxial stability. The posterior screw-rod system and screw-plate system may have higher risks of screw loosening and breakage. The Harms plate and TARP model may more effectively relieve nonfixed segment degeneration than other techniques. The C0/1 or C2/3 segment may not be more susceptible to degeneration than other nonfixed segments after C1/2 fixation.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Biomechanical comparison of three different fixation techniques for anterior column posterior hemitransverse acetabular fractures using anterior intrapelvic approach
    Tanoglu, Oguzhan
    Alemdaroglu, Kadir Bahadir
    Iltar, Serkan
    Ozmeric, Ahmet
    Demir, Teyfik
    Erbay, Fatma Kubra
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (08): : 1513 - 1519
  • [42] Biomechanical evaluation of anterior and posterior lumbar surgical approaches on the adjacent segment: a finite element analysis
    Wang, Bingjin
    Ke, Wencan
    Hua, Wenbin
    Lu, Saideng
    Zeng, Xianlin
    Yang, Cao
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (14) : 1109 - 1116
  • [43] Salvage posterior atlantoaxial fixation techniques: A retrospective study
    Secer, Mehmet
    Karakoyun, Oguz Durmus
    Ulutas, Murat
    Gokbel, Aykut
    Cinar, Kadir
    Yigitkanli, Kazim
    NEUROCIRUGIA, 2022, 33 (06): : 310 - 317
  • [44] Design a novel integrated screw for minimally invasive atlantoaxial anterior transarticular screw fixation: a finite element analysis
    Zhang, Yingkai
    Li, Cheng
    Li, Lei
    Sun, Yanyan
    Li, Zeqing
    Mei, Yunli
    Feng, Xinyuan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [45] Design a novel integrated screw for minimally invasive atlantoaxial anterior transarticular screw fixation: a finite element analysis
    Yingkai Zhang
    Cheng Li
    Lei Li
    Yanyan Sun
    Zeqing Li
    Yunli Mei
    Xinyuan Feng
    Journal of Orthopaedic Surgery and Research, 15
  • [46] A biomechanical comparison of different fixation techniques for fractures of the acetabular posterior wall
    Wu, Xinbao
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (03) : 673 - 679
  • [47] A biomechanical comparison of different fixation techniques for fractures of the acetabular posterior wall
    Xinbao Wu
    International Orthopaedics, 2018, 42 : 673 - 679
  • [48] Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
    Hu, Pan
    Wu, Tao
    Wang, Hui-zhi
    Qi, Xin-zheng
    Yao, Jie
    Cheng, Xiao-dong
    Chen, Wei
    Zhang, Ying-ze
    ORTHOPAEDIC SURGERY, 2019, 11 (02) : 195 - 203
  • [49] Biomechanical analysis of posterior fixation techniques in a 360° arthrodesis model
    Burton, D
    McIff, T
    Fox, T
    Lark, R
    Asher, MA
    Glattes, RC
    SPINE, 2005, 30 (24) : 2765 - 2771
  • [50] Biomechanical analysis for five fixation techniques of Pauwels-III fracture by finite element modeling
    Peng, Matthew Jian-Qiao
    Xu, HongWen
    Chen, Hai-Yan
    Lin, Ze
    Li, XinXu
    Shen, ChuLong
    Lau, YongQiang
    He, ErXing
    Guo, YueMing
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 193