Biomechanical properties of different anterior and posterior techniques for atlantoaxial fixation: a finite element analysis

被引:3
|
作者
Li, Jie [1 ]
Cao, Shuai [2 ]
Guo, Dong [1 ]
Lu, Teng [1 ]
Zang, Quanjin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Orthoped, 157Th West Fifth Rd, Xian 710004, Shaanxi, Peoples R China
[2] Civil Aviat Gen Hosp, Dept Orthoped, 1 Gaojing Stress, Beijing 100123, Peoples R China
关键词
Atlantoaxial fixation; Nonfixed segment degeneration; Segmental stability; Stress concentration; Finite element; TRANSARTICULAR SCREW FIXATION; CERVICAL-SPINE; DISLOCATION; REDUCTION; INSTABILITY; FUSION; TARP;
D O I
10.1186/s13018-023-03905-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundMany techniques for atlantoaxial fixation have been developed. However, the biomechanical differences among various atlantoaxial fixation methods remain unclear. This study aimed to evaluate the biomechanical influence of anterior and posterior atlantoaxial fixation techniques on fixed and nonfixed segments.MethodsAn occiput-C7 cervical finite element model was used to construct 6 surgical models including a Harms plate, a transoral atlantoaxial reduction plate (TARP), an anterior transarticular screw (ATS), a Magerl screw, a posterior screw-plate, and a screw-rod system. Range of motion (ROM), facet joint force (FJF), disc stress, screw stress, and bone-screw interface stress were calculated.ResultsThe C1/2 ROMs were relatively small in the ATS and Magerl screw models under all loading directions except for extension (0.1 & DEG;-1.0 & DEG;). The posterior screw-plate system and screw-rod system generated greater stresses on the screws (77.6-1018.1 MPa) and bone-screw interfaces (58.3-499.0 MPa). The Harms plate and TARP models had relatively small ROMs (3.2 & DEG;-17.6 & DEG;), disc stress (1.3-7.6 MPa), and FJF (3.3-106.8 N) at the nonfixed segments. Changes in disc stress and FJF of the cervical segments were not consistent with changes in ROM.ConclusionsATS and Magerl screws may provide good atlantoaxial stability. The posterior screw-rod system and screw-plate system may have higher risks of screw loosening and breakage. The Harms plate and TARP model may more effectively relieve nonfixed segment degeneration than other techniques. The C0/1 or C2/3 segment may not be more susceptible to degeneration than other nonfixed segments after C1/2 fixation.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Biomechanical Properties of Different Fixation Techniques for Posterior Cruciate Ligament Avulsion Fractures
    Domnick, Christoph
    Koesters, Clemens
    Franke, Friederike
    Raschke, Michael J.
    Petersen, Wolf
    Fink, Christian
    Herbort, Mirco
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (06): : 1065 - 1071
  • [22] Biomechanical evaluation of different semi-rigid junctional fixation techniques using finite element analysis
    van Agtmaal, Julia L.
    Doodkorte, Remco J. P.
    Roth, Alex K.
    Ito, Keita
    Arts, Jacobus J. C.
    Willems, Paul C.
    van Rietbergen, Bert
    CLINICAL BIOMECHANICS, 2023, 108
  • [23] Finite Element Analysis of 3 Posterior Fixation Techniques in the Lumbar Spine
    Gong, Zhiqiang
    Chen, Zixian
    Feng, Zhenzhou
    Cao, Yuanwu
    Jiang, Chun
    Jiang, Xiaoxing
    ORTHOPEDICS, 2014, 37 (05) : E441 - E448
  • [24] Biomechanical effects of anterior, posterior, and combined anterior-posterior instrumentation techniques on the stability of a multilevel cervical corpectomy construct: a finite element model analysis
    Hussain, Mozammil
    Nassr, Ahmad
    Natarajan, Raghu N.
    An, Howard S.
    Andersson, Gunnar B. J.
    SPINE JOURNAL, 2011, 11 (04): : 324 - 330
  • [25] Biomechanical comparison of a novel transoral atlantoaxial anchored cage with established fixation technique - a finite element analysis
    Zhang, Bao-cheng
    Liu, Hai-bo
    Cai, Xian-hua
    Wang, Zhi-hua
    Xu, Feng
    Kang, Hui
    Ding, Ran
    Luo, Xiao-qing
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [26] Biomechanical comparison of a novel transoral atlantoaxial anchored cage with established fixation technique - a finite element analysis
    Bao-cheng Zhang
    Hai-bo Liu
    Xian-hua Cai
    Zhi-hua Wang
    Feng Xu
    Hui Kang
    Ran Ding
    Xiao-qing Luo
    BMC Musculoskeletal Disorders, 16
  • [27] Comparative biomechanical evaluation of fixation methods in posterior pilon fractures: a finite element analysis
    Zhang, Yong-Tao
    Liu, Song
    Fu, Su
    Wu, Jian-Qun
    Yu, Bin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (01): : 16 - 27
  • [28] Biomechanical comparison of fixation systems in posterior wall fracture of acetabular by finite element analysis
    Lei, Jianyin
    Liu, Haibo
    Li, Zhiqiang
    Wang, Zhihua
    Liu, Ximing
    Zhao, Longmao
    COMPUTER ASSISTED SURGERY, 2016, 21 (01): : 117 - 126
  • [29] Evaluation of biomechanical properties of anterior atlantoaxial transarticular locking plate system using three-dimensional finite element analysis
    Xian-hua Cai
    Zhi-chao Liu
    Yang Yu
    Mei-chao Zhang
    Wei-bing Huang
    European Spine Journal, 2013, 22 : 2686 - 2694
  • [30] Posterior atlantoaxial fixation of osteoporotic odontoid fracture: biomechanical analysis of the Magerl versus harms techniques in a cadaver model
    Mike-Mayer, Austin
    Lam, Kendrick
    Morris, Randal P.
    Al Barghouthi, Abeer
    Travascio, Francesco
    Latta, Loren L.
    Lindsey, Ronald W.
    SPINE JOURNAL, 2024, 24 (08): : 1510 - 1516