Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium

被引:1
|
作者
Fransson, Veronica [1 ,2 ]
Mellander, Helena [3 ,4 ]
Ramgren, Birgitta [3 ,4 ]
Andersson, Henrik [3 ,4 ]
Arena, Francesco [3 ]
Ydstroem, Kristina [1 ,5 ]
Ullberg, Teresa [6 ]
Wasselius, Johan [3 ,4 ]
机构
[1] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[2] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
[3] Skane Univ Hosp, Dept Med Imaging & Physiol, S-22185 Lund, Sweden
[4] Lund Univ, Dept Clin Sci, Lund, Sweden
[5] Lund Univ, Dept Clin Sci, Med Radiat Phys, Lund, Sweden
[6] Lund Univ, Skane Univ Hosp, Dept Clin Sci Lund, Neurol, Lund, Sweden
关键词
Computed tomography angiography; Contrast material reduction; Dual-energy CT; Spectral CT; Virtual monoenergetic images; Contrast-induced nephropathy; DUAL-ENERGY CT; VGC ANALYZER; ROC SOFTWARE; TUBE-VOLTAGE; REDUCTION; FREQUENCY; VIEWDEX; KIDNEY; LOAD; TOOL;
D O I
10.1007/s00234-023-03190-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeReduction in iodinated contrast medium (CM) dose is highly motivated. Our aim was to evaluate if a 50% reduction of CM, while preserving image quality, is possible in brain CT angiography (CTA) using virtual monoenergetic images (VMI) on spectral CT. As a secondary aim, we evaluated if VMI can salvage examinations with suboptimal CM timing.MethodsConsecutive patients older than 18 years without intracranial stenosis/occlusion were included. Three imaging protocols were used: group 1, full CM dose; group 2, 50% CM dose suboptimal timing; and group 3, 50% CM dose optimized timing.Attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured in the internal carotid artery, M2 segment of the middle cerebral artery, and white matter for conventional images (CI) and VMI (40-200 keV). Qualitative image quality for CI and VMI (50 and 60 keV) was rated by 4 experienced reviewers.ResultsQualitatively and quantitatively, VMI (40-60 keV) improved image quality within each group. Significantly higher attenuation and CNR was found for group 3 VMI 40-50 keV, with unchanged SNR, compared to group 1 CI. Group 3 VMI 50 keV also received significantly higher rating scores than group 1 CI. Group 2 VMI (40-50 keV) had significantly higher CNR compared to group 3 CI, but the subjective image quality was similar.ConclusionVMI of 50 keV with 50% CM dose increases qualitative and quantitative image quality over CI with full CM dose. Using VMI reduces non-diagnostic examinations and may salvage CTA examinations deemed non-diagnostic due to suboptimal timing.
引用
收藏
页码:1333 / 1342
页数:10
相关论文
共 50 条
  • [21] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Schicchi, Nicolo
    Fogante, Marco
    Oliva, Matteo
    Pirani, Paolo Esposto
    Agliata, Giacomo
    Giuseppetti, Gian Marco
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (03): : 184 - 190
  • [22] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Nicolò Schicchi
    Marco Fogante
    Matteo Oliva
    Paolo Esposto Pirani
    Giacomo Agliata
    Gian Marco Giuseppetti
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 184 - 190
  • [23] Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography
    van der Bijl, Noortje
    Joemai, Raoul M. S.
    Mertens, Bart J. A.
    de Roos, Albert
    Veldkamp, Wouter J. H.
    Bax, Jeroen J.
    Schuijf, Joanne D.
    Geleijns, Jacob
    Kroft, Lucia J. M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (02): : 453 - 461
  • [24] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6
  • [25] Application of Aortic Computed Tomography Angiography with Low Radiation Dose: Assessment of Image Quality and Radiation Dose
    Liu, Jianhua
    Li, Long
    Zhang, Yan
    Yuan, Qinghai
    Sun, Yong
    2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 148 - 151
  • [26] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [27] Image quality and dose in spiral computed tomography
    Verdun, FR
    Meuli, RA
    Bochud, FO
    Imsand, C
    Raimondi, S
    Schnyder, P
    Valley, JF
    EUROPEAN RADIOLOGY, 1996, 6 (04) : 485 - 488
  • [28] Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta
    Wong, Ying Mei
    Ong, Ching Ching
    Liang, Chong Ri
    Tan, Choon Ann
    Teo, Lynette Li San
    SINGAPORE MEDICAL JOURNAL, 2024, 65 (02) : 84 - 90
  • [29] Computed tomography lung iodine contrast mapping by image registration and subtraction
    Goatman, Keith
    Plakas, Costas
    Schuijf, Joanne
    Beveridge, Erin
    Prokop, Mathias
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [30] Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison
    Forte, Ernesto
    Monti, Serena
    Parente, Chiara Anna
    Beyer, Lukas
    De Rosa, Roberto
    Infante, Teresa
    Cavaliere, Carlo
    Cademartiri, Filippo
    Salvatore, Marco
    Stroszczynski, Christian
    Tedeschi, Carlo
    DOSE-RESPONSE, 2018, 16 (04):