Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta

被引:1
|
作者
Wong, Ying Mei [1 ]
Ong, Ching Ching [1 ]
Liang, Chong Ri [1 ]
Tan, Choon Ann [1 ]
Teo, Lynette Li San [1 ,2 ]
机构
[1] Natl Univ Singapore Hosp, Dept Diagnost Imaging, Singapore, Singapore
[2] Natl Univ Singapore Hosp, Dept Diagnost Imaging, 1E Kent Ridge Rd,NUHS Tower Block,Level 12, Singapore 119228, Singapore
关键词
Aortic diseases; computed tomography angiography; radiation dosage; retrospective studies; signal-to-noise ratio; HIGH-PITCH CT; DISSECTION;
D O I
10.11622/smedj.2021166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Computed tomography angiography of the aorta (CTAA) is the modality of choice for investigating aortic disease. Our aim was to evaluate the image quality, contrast enhancement and radiation dose of electrocardiograph (ECG)-triggered and non-ECG-triggered CTAA on a 256-slice single-source CT scanner. This allows the requesting clinician and the radiologist to balance radiation risk and image quality. Methods: We retrospectively assessed the data of 126 patients who had undergone CTAA on a single-source CT scanner using ECG-triggered (group 1, n = 77) or non-ECG-triggered (group 2, n = 49) protocols. Radiation doses were compared. Qualitative (4-point scale) and quantitative image quality assessments were performed. Results: The mean volume CT dose index, dose length product and effective dose in group 1 were 12.4 +/- 1.9 mGy, 765.8 +/- 112.4 mGy cm and 13.0 +/- 1.9 mSv, respectively. These were significantly higher compared to group 2 values (9.1 +/- 2.6 mGy, 624.1 +/- 174.8 mGy cm and 10.6 +/- 3.0 mSv, respectively) ( P < 0.001). Qualitative assessment showed the image quality at the aortic root-proximal ascending aorta was significantly higher in group 1 (median 3) than in group 2 (median 2, P < 0.001). Quantitative assessment showed significantly better mean arterial attenuation, signal-to-noise ratio and contrast-to-noise ratio in ECG-triggered CTAA compared to non-ECG-triggered CTAA. Conclusion: ECG-triggered CTAA in a single-source scanner has superior image quality and vessel attenuation of aortic root/ascending aorta, but a higher radiation dose of approximately 23%. Its use should be considered specifically when assessing aortic root/ascending aorta pathology.
引用
收藏
页码:84 / 90
页数:7
相关论文
共 50 条
  • [1] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    INFORMATICA, 2021, 32 (04) : 741 - 757
  • [2] Image quality and radiation exposure with low-contrast-dose computed tomography angiography of the lower extremities
    Assi, Abed Al Nasser
    POLISH JOURNAL OF RADIOLOGY, 2020, 85 : E169 - E173
  • [3] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Komatsu, Sei
    Kamata, Teruaki
    Imai, Atsuko
    Ohara, Tomoki
    Takewa, Mitsuhiko
    Ohe, Ryoko
    Miyaji, Kazuaki
    Yoshida, Junichi
    Kodama, Kazuhisa
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1335 - 1340
  • [4] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Sei Komatsu
    Teruaki Kamata
    Atsuko Imai
    Tomoki Ohara
    Mitsuhiko Takewa
    Ryoko Ohe
    Kazuaki Miyaji
    Junichi Yoshida
    Kazuhisa Kodama
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1335 - 1340
  • [5] Application of Aortic Computed Tomography Angiography with Low Radiation Dose: Assessment of Image Quality and Radiation Dose
    Liu, Jianhua
    Li, Long
    Zhang, Yan
    Yuan, Qinghai
    Sun, Yong
    2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 148 - 151
  • [6] Image Quality, Contrast Enhancement, and Radiation Dose of ECG-Triggered High-Pitch CT Versus Non-ECG-Triggered Standard-Pitch CT of the Thoracoabdominal Aorta
    Bolen, Michael A.
    Popovic, Zoran B.
    Tandon, Navdeep
    Flamm, Scott D.
    Schoenhagen, Paul
    Halliburton, Sandra S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (04) : 931 - 938
  • [7] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [8] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Schicchi, Nicolo
    Fogante, Marco
    Oliva, Matteo
    Pirani, Paolo Esposto
    Agliata, Giacomo
    Giuseppetti, Gian Marco
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (03): : 184 - 190
  • [9] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Nicolò Schicchi
    Marco Fogante
    Matteo Oliva
    Paolo Esposto Pirani
    Giacomo Agliata
    Gian Marco Giuseppetti
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 184 - 190
  • [10] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6