Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta

被引:1
|
作者
Wong, Ying Mei [1 ]
Ong, Ching Ching [1 ]
Liang, Chong Ri [1 ]
Tan, Choon Ann [1 ]
Teo, Lynette Li San [1 ,2 ]
机构
[1] Natl Univ Singapore Hosp, Dept Diagnost Imaging, Singapore, Singapore
[2] Natl Univ Singapore Hosp, Dept Diagnost Imaging, 1E Kent Ridge Rd,NUHS Tower Block,Level 12, Singapore 119228, Singapore
关键词
Aortic diseases; computed tomography angiography; radiation dosage; retrospective studies; signal-to-noise ratio; HIGH-PITCH CT; DISSECTION;
D O I
10.11622/smedj.2021166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Computed tomography angiography of the aorta (CTAA) is the modality of choice for investigating aortic disease. Our aim was to evaluate the image quality, contrast enhancement and radiation dose of electrocardiograph (ECG)-triggered and non-ECG-triggered CTAA on a 256-slice single-source CT scanner. This allows the requesting clinician and the radiologist to balance radiation risk and image quality. Methods: We retrospectively assessed the data of 126 patients who had undergone CTAA on a single-source CT scanner using ECG-triggered (group 1, n = 77) or non-ECG-triggered (group 2, n = 49) protocols. Radiation doses were compared. Qualitative (4-point scale) and quantitative image quality assessments were performed. Results: The mean volume CT dose index, dose length product and effective dose in group 1 were 12.4 +/- 1.9 mGy, 765.8 +/- 112.4 mGy cm and 13.0 +/- 1.9 mSv, respectively. These were significantly higher compared to group 2 values (9.1 +/- 2.6 mGy, 624.1 +/- 174.8 mGy cm and 10.6 +/- 3.0 mSv, respectively) ( P < 0.001). Qualitative assessment showed the image quality at the aortic root-proximal ascending aorta was significantly higher in group 1 (median 3) than in group 2 (median 2, P < 0.001). Quantitative assessment showed significantly better mean arterial attenuation, signal-to-noise ratio and contrast-to-noise ratio in ECG-triggered CTAA compared to non-ECG-triggered CTAA. Conclusion: ECG-triggered CTAA in a single-source scanner has superior image quality and vessel attenuation of aortic root/ascending aorta, but a higher radiation dose of approximately 23%. Its use should be considered specifically when assessing aortic root/ascending aorta pathology.
引用
收藏
页码:84 / 90
页数:7
相关论文
共 50 条
  • [11] Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography
    Mousavi-Gazafroudi, Seyedeh Shokoofeh
    Sajjadieh-Khajouei, Amirreza
    Moradi, Maryam
    Mousavi-Gazafroudi, Seyedeh Shabnam
    Yadegarfar, Ghasem
    Tavakoli, Mohammad Bagher
    ARYA ATHEROSCLEROSIS, 2019, 15 (05) : 205 - 210
  • [12] Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium
    Veronica Fransson
    Helena Mellander
    Birgitta Ramgren
    Henrik Andersson
    Francesco Arena
    Kristina Ydström
    Teresa Ullberg
    Johan Wassélius
    Neuroradiology, 2023, 65 : 1333 - 1342
  • [13] Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium
    Fransson, Veronica
    Mellander, Helena
    Ramgren, Birgitta
    Andersson, Henrik
    Arena, Francesco
    Ydstroem, Kristina
    Ullberg, Teresa
    Wasselius, Johan
    NEURORADIOLOGY, 2023, 65 (09) : 1333 - 1342
  • [14] The effect of contrast material on radiation dose during computed tomography pulmonary angiography
    Karami, Haleh
    Miri-Hakimabad, Hashem
    Hoseinian-Azghadi, Elie
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03): : 211 - 221
  • [15] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Kjell Bogaard
    Friso M. van der Zant
    Remco J. J. Knol
    Sjoerd Reinders
    Marije M. G. Krul
    Albert C. van Rossum
    Paul Knaapen
    Jan H. Cornel
    The International Journal of Cardiovascular Imaging, 2015, 31 : 125 - 133
  • [16] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Bogaard, Kjell
    van der Zant, Friso M.
    Knol, Remco J. J.
    Reinders, Sjoerd
    Krul, Marije M. G.
    van Rossum, Albert C.
    Knaapen, Paul
    Cornel, Jan H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (01): : 125 - 133
  • [17] Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose
    Linsen, Philip V. M.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Dijkshoorn, Marcel L.
    Ouhlous, Mohamed
    Nieman, Koen
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6
  • [18] High-Pitch Dual-Source Computed Tomography Renal Angiography Comparison With Conventional Low-Pitch Computed Tomography Angiography: Image Quality, Contrast Medium Volume, and Radiation Dose
    Pang, LiFang
    Zhao, Yue
    Dong, HaiPeng
    Shi, HongCheng
    Yang, WenJie
    Zhang, Huan
    Yan, FuHua
    Liu, Bo
    Yan, Jing
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 737 - 740
  • [19] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [20] Radiation Dose and Image Quality in Adult Computed Tomography Scans
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Theeb, Mostafa Abdelrahman
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 223 - 231