Hemodynamic parameters impact the stability of distal stent graft-induced new entry

被引:3
|
作者
Wang, Kaihong [1 ]
Armour, Chloe H. [1 ]
Ma, Tao [2 ]
Dong, Zhihui [2 ]
Xu, Xiao Yun [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, South Kensington Campus, London SW7 2AZ, England
[2] Fudan Univ, Zhongshan Hosp, Dept Vasc Surg, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
ENDOVASCULAR AORTIC REPAIR; STEEL-BASED DEVICE; IN-VIVO; DISSECTION; FLOW; PLACEMENT; VESSEL; BLOOD; MRI;
D O I
10.1038/s41598-023-39130-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Stent graft-induced new entry tear (SINE) is a serious complication in aortic dissection patients caused by the stent-graft itself after thoracic endovascular aortic repair (TEVAR). The stability of SINE is a key indicator for the need and timing of reinterventions. This study aimed to understand the role of hemodynamics in SINE stability by means of computational fluid dynamics (CFD) analysis based on patient-specific anatomical information. Four patients treated with TEVAR who developed a distal SINE (dSINE) were included; two patients had a stable dSINE and two patients experienced expansion of the dSINE upon follow-up examinations. CFD simulations were performed on geometries reconstructed from computed tomography scans acquired upon early detection of dSINE in these patients. Computational results showed that stable dSINEs presented larger regions with low time-averaged wall shear stress (TAWSS) and high relative residence time (RRT), and partial thrombosis was observed at subsequent follow-ups. Furthermore, significant systolic antegrade flow was observed in the unstable dSINE which also had a larger retrograde flow fraction (RFF) on the SINE plane. In conclusion, this pilot study suggested that high RRT and low TAWSS may indicate stable dSINE by promoting thrombosis, whereas larger RFF and antegrade flows inside dSINE might be associated with its expansion.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Distal stent graft-induced new entries following frozen elephant trunk procedure
    Kreibich, Maximilian
    Berger, Tim
    Siepe, Matthias
    Czerny, Martin
    Rylski, Bartosz
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2022, 36 (04): : 260 - 263
  • [32] Early Prediction of Distal Stent Graft-Induced New Entry after Thoracic Endovascular Aortic Repair with Computational Fluid Dynamics
    School of Medical Technology, Beijing Institute of Technology, China
    ACM Int. Conf. Proc. Ser., 1600, (84-90):
  • [33] Impact Factors of Distal Stent Graft Induced New Entry in Type B Aortic Dissection
    Chen, I-Ming
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : S31 - S31
  • [34] Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection
    Weng, Shih-Hsien
    Weng, Chi-Feng
    Chen, Wei-Yuan
    Huang, Chun-Yang
    Chen, I-Ming
    Chen, Chun-Ku
    Hsu, Chiao-Po
    Shih, Chun-Che
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 64 - 71
  • [35] Risk factors for distal stent graft-induced new entry in type B aortic dissections: Systematic review and meta-analysis
    D'cruz, Reuban T.
    Syn, Nicholas
    Wee, Ian
    Choong, Andrew M. T. L.
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : 1682 - +
  • [36] Prevention of distal stent graft-induced new entry after endovascular repair for type B aortic dissection: A retrospective cohort study
    Li, Xianwei
    Zhang, Yingnan
    Sun, Zhanfeng
    Wang, Haitao
    Zhang, Chuanqi
    Cui, Yunfu
    Jiang, Weiliang
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 167 (01): : 28 - +
  • [37] Aortic remodeling mismatch: A potential risk factor of late distal stent graft-induced new entry after frozen elephant trunk deployment
    Wada, Takuya
    Yamamoto, Hiroshi
    Kadohama, Takayuki
    Takagi, Daichi
    JTCVS TECHNIQUES, 2021, 8 : 46 - 48
  • [38] Stent graft-induced new entry tear after endoluminal grafting for aortic dissection repaired with open interposition graft
    Gomero-Cure, Wadi
    Lowery, Robert C.
    O'Donnell, Sean
    JOURNAL OF VASCULAR SURGERY, 2013, 58 (06) : 1652 - 1656
  • [39] Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection
    Dong, Zhihui
    Fu, Weiguo
    Wang, Yuqi
    Wang, Chunsheng
    Yan, Zhiping
    Guo, Daqiao
    Xu, Xin
    Chen, Bin
    JOURNAL OF VASCULAR SURGERY, 2010, 52 (06) : 1450 - 1457
  • [40] Implantation sequence modification averts distal stent graft-induced new entry after endovascular repair of Stanford type B aortic dissection
    Chen, I-Ming
    Huang, Chun-Yang
    Weng, Shih-Hsien
    Lin, Ping-Yi
    Chen, Po-Lin
    Chen, Wei-Yuan
    Shih, Chun-Che
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (02) : 281 - 288