Hemodynamic parameters impact the stability of distal stent graft-induced new entry

被引:3
|
作者
Wang, Kaihong [1 ]
Armour, Chloe H. [1 ]
Ma, Tao [2 ]
Dong, Zhihui [2 ]
Xu, Xiao Yun [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, South Kensington Campus, London SW7 2AZ, England
[2] Fudan Univ, Zhongshan Hosp, Dept Vasc Surg, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
ENDOVASCULAR AORTIC REPAIR; STEEL-BASED DEVICE; IN-VIVO; DISSECTION; FLOW; PLACEMENT; VESSEL; BLOOD; MRI;
D O I
10.1038/s41598-023-39130-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Stent graft-induced new entry tear (SINE) is a serious complication in aortic dissection patients caused by the stent-graft itself after thoracic endovascular aortic repair (TEVAR). The stability of SINE is a key indicator for the need and timing of reinterventions. This study aimed to understand the role of hemodynamics in SINE stability by means of computational fluid dynamics (CFD) analysis based on patient-specific anatomical information. Four patients treated with TEVAR who developed a distal SINE (dSINE) were included; two patients had a stable dSINE and two patients experienced expansion of the dSINE upon follow-up examinations. CFD simulations were performed on geometries reconstructed from computed tomography scans acquired upon early detection of dSINE in these patients. Computational results showed that stable dSINEs presented larger regions with low time-averaged wall shear stress (TAWSS) and high relative residence time (RRT), and partial thrombosis was observed at subsequent follow-ups. Furthermore, significant systolic antegrade flow was observed in the unstable dSINE which also had a larger retrograde flow fraction (RFF) on the SINE plane. In conclusion, this pilot study suggested that high RRT and low TAWSS may indicate stable dSINE by promoting thrombosis, whereas larger RFF and antegrade flows inside dSINE might be associated with its expansion.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Distal Stent Graft-Induced New Entry After Frozen Elephant Trunk Procedure for Aortic Dissection
    Hiraoka, Toshifumi
    Furukawa, Tomokuni
    Imai, Katsuhiko
    Takahashi, Shinya
    ANNALS OF VASCULAR SURGERY, 2023, 97 : 340 - 350
  • [12] Distal stent graft-induced new entry (dSINE) after frozen elephant trunk: a scoping review
    Murana, Giacomo
    Costantino, Antonino
    Campanini, Francesco
    Fiaschini, Costanza
    Buia, Francesco
    Mariani, Carlo
    Leone, Alessandro
    Di Marco, Luca
    Pacini, Davide
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2023, 13 (02) : 408 - 417
  • [13] Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection
    Zhao, Yang
    Yin, Henghui
    Chen, Yitian
    Wang, Mian
    Zheng, Liang
    Li, Zilun
    Chang, Guangqi
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) : 93 - 103
  • [14] The PETTICOAT-Snowshoe Technique Prevents Distal Stent Graft-Induced New Entry in Patients with Aortic Dissection
    Orimoto, Yuki
    Ishibashi, Hiroyuki
    Maruyama, Yuki
    Imaeda, Yusuke
    Mitsuoka, Hiroki
    Arima, Takahiro
    Suzuki, Kojiro
    ANNALS OF VASCULAR SURGERY, 2022, 84 : 201 - 210
  • [15] Relevance of Aortic Dissection Chronicity to the Development of Stent Graft-induced New Entry
    Ouchi, Takafumi
    Kato, Noriyuki
    Kato, Hiroaki
    Higashigawa, Takatoshi
    Ito, Hisato
    Nakajima, Ken
    Chino, Shuji
    Tokui, Toshiya
    Mizumoto, Toru
    Sakuma, Hajime
    ANNALS OF THORACIC SURGERY, 2020, 110 (06): : 1983 - 1989
  • [16] Distal Stent Graft-Induced New Entry after Total Arch Replacement with Frozen Elephant Trunk for Aortic Dissection
    Nomura, Yoshikatsu
    Tonoki, Shuto
    Kawashima, Motoharu
    Fujisue, Jun
    Uchino, Gaku
    Miyahara, Shunsuke
    Tanaka, Hiroshi
    Honda, Tasuku
    Mukohara, Nobuhiko
    Murakami, Hirohisa
    ANNALS OF VASCULAR DISEASES, 2021, 14 (04) : 362 - 367
  • [17] Rapidly Progressed Distal Arch Aneurysm with Distal Open Stent Graft-Induced New Entry Caused by "Spring-Back" Force
    Takagaki, Masami
    Midorikawa, Hirofumi
    Yamaguchi, Hiroki
    Nakamura, Hiromasa
    Kadowaki, Tasuku
    Ueno, Yousuke
    Uchida, Takaki
    Aoki, Tomoyuki
    ANNALS OF VASCULAR DISEASES, 2020, 13 (03) : 343 - 346
  • [18] Evaluation of flow dynamics in distal stent graft-induced new entry using 4D flow MRI
    Sakakibara, Kenji
    Nakajima, Hiroyuki
    Hagihara, Yudai
    Nakamura, Chie
    Shikata, Daichi
    Takesue, Yuki
    Shiraiwa, Satoru
    Honda, Yoshihiro
    Kaga, Shigeaki
    Hamasaki, Masahiro
    Johno, Hisashi
    CLINICAL CASE REPORTS, 2024, 12 (04):
  • [19] Early Experience With a Novel Thoracic Stent Design for the Prevention of Distal Stent Graft-Induced New Entry Tears (d-SINE)
    Burdess, Anne
    Mani, Kevin
    Tegler, Gustaf
    Wanhainen, Anders
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (05) : E153 - E153
  • [20] Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection
    Li, Qing
    Wang, Long-Fei
    Ma, Wei-Guo
    Xu, Shang-Dong
    Zheng, Jun
    Xing, Xiao-Yan
    Huang, Lian-Jun
    Sun, Li-Zhong
    JOURNAL OF THORACIC DISEASE, 2015, 7 (11) : 1907 - 1916