Linear plasma device GyM for plasma-material interaction studies

被引:9
|
作者
Uccello, Andrea [1 ]
Bin, William [1 ]
Bruschi, Alessandro [1 ]
Causa, Federica [1 ]
Cremona, Anna [1 ]
De Angeli, Marco [1 ]
Farina, Daniela [1 ]
Gatto, Giuseppe [1 ]
Gervasini, Gabriele [1 ]
Ghezzi, Francesco [1 ]
Gittini, Giuseppe [1 ]
Granucci, Gustavo [1 ]
Grosso, Giovanni [1 ]
Laguardia, Laura [1 ]
Lontano, Maurizio [1 ]
Mellera, Vittoria [1 ]
Minelli, Daniele [1 ]
Nardone, Antonio [1 ]
Pedroni, Matteo [1 ]
Ripamonti, Federico [1 ]
Rispoli, Natale [1 ]
Vassallo, Espedito [1 ]
Ricci, Daria [1 ]
机构
[1] CNR, Ist Sci & Tecnol Plasmi, Milan, Italy
关键词
nuclear fusion; tokamak; linear plasma device; GyM; plasma-facing components; plasma-material interaction; FLUX DEUTERIUM PLASMA; LOW-ENERGY; SURFACE-MORPHOLOGY; AMMONIA PRODUCTION; EROSION; RETENTION; PISCES; DUST; PSI-2; JET;
D O I
10.3389/fphy.2023.1108175
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
GyM is a linear plasma device operating at Istituto per la Scienza e Tecnologia dei Plasmi, Consiglio Nazionale delle Ricerche, Milan, with the original aim of studying basic plasma physics, such as turbulent processes. Since 2014, GyM experimental program has been mainly focused on the issue of plasma-material interaction (PMI) for magnetic confinement nuclear fusion applications. GyM consists of a stainless steel vacuum chamber (radius and length of 0.125 m and 2.11 m), a pumping system, a gas injection system, 10 magnetic field coils and two magnetron sources at 2.45 GHz, capable of delivering a total microwave power up to 4.5 kW. Highly reproducible steady-state plasmas of different gas species, at a maximum working pressure of & SIM; 1 0 - 1 Pa, can be obtained by electron cyclotron resonance heating in the resonance layer at 87.5 mT. Plasmas of GyM have electron and ion temperature & LE;15 eV and & SIM;0.1 eV, respectively. The electron density is in the range of 10(15)-10(17) m(-3) and the ion flux is <= 5 x 10(20) ions.m(-2)s(-1). Main plasma diagnostics of GyM comprise Langmuir probes, an optical emission spectrometer, a mass spectrometer and a fast camera system equipped with an image intensifier unit. For the purpose of investigating the topic of PMI, GyM is provided with two sample exposure systems. Both are biasable at a negative bias voltage down to -400 V, to tune the energy of the impinging ions. One of them is also equipped with a heating lamp and can reach and sustain a temperature of 990 K for several hours, thus allowing to study the role of sample temperature during the plasma-material interaction. This contribution presents the layout of GyM, the diagnostics, the sample exposure systems and the typical plasma parameters. A brief overview of the main PMI activities carried out so far and a description of future machine upgrades are also given.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Lithium-based surfaces controlling fusion plasma behavior at the plasma-material interface
    Allain, Jean Paul
    Taylor, Chase N.
    PHYSICS OF PLASMAS, 2012, 19 (05)
  • [32] Vulcan: A steady-state tokamak for reactor-relevant plasma-material interaction science
    Olynyk, G. M.
    Hartwig, Z. S.
    Whyte, D. G.
    Barnard, H. S.
    Bonoli, P. T.
    Bromberg, L.
    Garrett, M. L.
    Haakonsen, C. B.
    Mumgaard, R. T.
    Podpaly, V. A.
    FUSION ENGINEERING AND DESIGN, 2012, 87 (03) : 224 - 233
  • [33] Plasma-Material-Interaction Research Using PISCES Linear Plasma Devices
    Baldwin, M. J.
    Doerner, R. P.
    Nishijima, D.
    Patino, M.
    Simmonds, M. J.
    Tynan, G.
    Yu, J. H.
    Zaloznik, A.
    FUSION SCIENCE AND TECHNOLOGY, 2019, 75 (07) : 664 - 673
  • [34] Inverse mirror plasma experimental device (IMPED) - a magnetized linear plasma device for wave studies
    Bose, Sayak
    Chattopadhyay, P. K.
    Ghosh, J.
    Sengupta, S.
    Saxena, Y. C.
    Pal, R.
    JOURNAL OF PLASMA PHYSICS, 2015, 81
  • [35] General Criteria and Operation Limits of a Steady-State Fusion Reactor with Respect to Plasma-Material Interaction
    Naujoks, D.
    PLASMA INTERACTION IN CONTROLLED FUSION DEVICES, 2010, 1237 : 3 - 17
  • [36] JNM theme issue on models and data for plasma-material interaction and hydrogen retention in fusion devices Preface
    Braams, Bastiaan J.
    Chung, Hyun-Kyung
    JOURNAL OF NUCLEAR MATERIALS, 2015, 467 : 397 - 397
  • [37] HIGH-ENTHALPY PLASMA FACILITY FOR FUSION PLASMA MATERIAL INTERACTION STUDIES
    Hong, B. G.
    Kim, M. H.
    Seo, J. H.
    FUSION SCIENCE AND TECHNOLOGY, 2013, 63 (1T) : 213 - 216
  • [38] hPIC: A scalable electrostatic Particle-in-Cell for Plasma-Material Interactions
    Khaziev, Rinat
    Curreli, Davide
    COMPUTER PHYSICS COMMUNICATIONS, 2018, 229 : 87 - 98
  • [39] Plasma modelling for the PSI linear plasma device
    Kastelewiez, H
    Fussmann, G
    CONTRIBUTIONS TO PLASMA PHYSICS, 2004, 44 (04) : 352 - 360
  • [40] Dynamic Coupling of Boltzmann Plasma Model to Surface Erosion Model for Kinetic Treatment of Plasma-Material Interactions
    Keniley, S.
    Curreli, D.
    FUSION SCIENCE AND TECHNOLOGY, 2017, 71 (01) : 93 - 102