Development and validation of an optimal GATE model for proton pencil-beam scanning delivery

被引:2
|
作者
Asadi, Ali [1 ]
Akhavanallaf, Azadeh [2 ]
Hosseini, Seyed Abolfazl [1 ]
Vosoughi, Naser [1 ]
Zaidi, Habib [2 ,3 ,4 ,5 ,6 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[2] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Geneva, Neuroctr, Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[5] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[6] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2023年 / 33卷 / 04期
基金
瑞士国家科学基金会;
关键词
Proton therapy; Monte Carlo simulation; active scanning; AAPM TG-119; prostate; MONTE-CARLO SIMULATIONS; CARBON-ION THERAPY; DOSE-CALCULATION; OPTIMIZATION; CODE; DISTRIBUTIONS; PARAMETERS; EQUIVALENT; PLATFORM; TOPAS;
D O I
10.1016/j.zemedi.2022.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To develop and validate a versatile Monte Carlo (MC)-based dose calculation engine to support MC-based dose verification of treatment planning systems (TPSs) and quality assurance (QA) workflows in proton therapy. Methods: The GATE MC toolkit was used to simulate a fixed horizontal active scan-based proton beam delivery (SIEMENS IONTRIS). Within the nozzle, two primary and secondary dose monitors have been designed to enable the comparison of the accuracy of dose estimation from MC simulations with respect to physical QA measurements. The developed beam model was validated against a series of commissioning measurements using pinpoint chambers and 2D array ionization chambers (IC) in terms of lateral profiles and depth dose distributions. Furthermore, beam delivery module and treatment planning has been validated against the literature deploying various clinical test cases of the AAPM TG-119 (c-shape phantom) and a prostate patient. Results: MC simulations showed excellent agreement with measurements in the lateral depth-dose parameters and spread-out Bragg peak (SOBP) characteristics within a maximum relative error of 0.95 mm in range, 1.83% in entrance to peak ratio, 0.27% in mean point-to-point dose difference, and 0.32% in peak location. The mean relative absolute difference between MC simulations and measurements in terms of absorbed dose in the SOBP region was 0.93% +/- 0.88%. Clinical phantom studies showed a good agreement compared to research TPS (relative error for TG-119 planning target volume PTV-D95 = 1.8%; and for prostate PTV-D95 = -0.6%). Conclusion: We successfully developed a MC model for the pencil beam scanning system, which appears reliable for dose verification of the TPS in combination with QA information, prior to patient treatment.
引用
收藏
页码:591 / 600
页数:10
相关论文
共 50 条
  • [21] Clinical results and toxicities in pediatric CNS tumors treated with proton pencil-beam scanning
    Rombi, B.
    Ruggi, A.
    Ronchi, L.
    Buwenge, M.
    Ammendolia, I.
    Cammelli, S.
    Melchionda, F.
    Prete, A.
    Fracchiolla, F.
    Zucchelli, M.
    Morganti, G.
    Amichetti, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S653 - S654
  • [22] Successful Implementation of Image-Guided Pencil-Beam Scanning Proton Therapy in Medulloblastomas
    Das, Anindita
    Gaikwad, Utpal
    Krishnan, Ganapathy
    Rajendran, Adhithyan
    Patil, Sushama
    Subramaniam, Preethi
    Krishna, Uday
    Wakde, Manoj
    Chilukuri, Srinivas
    Jalali, Rakesh
    DIAGNOSTICS, 2023, 13 (21)
  • [23] Increased Efficiency of Range Verification in Routine QA for Pencil-Beam Scanning Proton Therapy
    Seonghoon Jeong
    Myonggeun Yoon
    Jaeman Son
    Kwangzoo Chung
    Journal of the Korean Physical Society, 2018, 73 : 983 - 989
  • [24] Increased Efficiency of Range Verification in Routine QA for Pencil-Beam Scanning Proton Therapy
    Jeong, Seonghoon
    Yoon, Myonggeun
    Son, Jaeman
    Chung, Kwangzoo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (07) : 983 - 989
  • [25] Interplay Effect of Target Motion and Pencil-Beam Scanning in Proton Therapy for Pediatric Patients
    Boria, Andrew J.
    Uh, Jinsoo
    Pirlepesov, Fakhriddin
    Stuckey, James C.
    Axente, Marian
    Gargone, Melissa A.
    Hua, Chia-ho
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2018, 5 (02) : 1 - 10
  • [26] A Novel Technique to Derive a Clinically-Acceptable Beam Model for Proton Pencil-Beam Scanning in a Commercial Treatment Planning System
    Scholey, J. E.
    Lin, L.
    Ainsley, C. G.
    MEDICAL PHYSICS, 2015, 42 (06) : 3527 - 3527
  • [27] Definition of dose rate for FLASH pencil-beam scanning proton therapy: A comparative study
    Deffet, Sylvain
    Hamaide, Valentin
    Sterpin, Edmond
    MEDICAL PHYSICS, 2023, 50 (09) : 5784 - 5792
  • [28] Dosimetric Impacts of Couch Moving Rails On Proton Treatment Using Pencil-Beam Scanning
    Zhang, Y.
    Park, J.
    Blalock, J.
    Stevens, R.
    Johnson, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E880 - E881
  • [29] Multi-Field Optimization Feasibility for Flash Pencil-Beam Scanning Proton Therapy
    Ramesh, P.
    Lyu, Q.
    Ruan, D.
    Sheng, K.
    MEDICAL PHYSICS, 2024, 51 (09) : 6568 - 6568
  • [30] Development and Validation of a TOPAS Monte Carlo Model of a Dynamic Collimation System for Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Culberson, W.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Smith, B.
    Flynn, R.
    Yu, J.
    Rana, S.
    Gutierrez, A.
    Hill, P.
    MEDICAL PHYSICS, 2021, 48 (06)