One-Piece Zirconia Oral Implants for the Support of Three-Unit Fixed Dental Prostheses: Three-Year Results from a Prospective Case Series

被引:3
|
作者
Kohal, Ralf-Joachim [1 ]
Vach, Kirstin [2 ]
Butz, Frank [1 ,3 ]
Spies, Benedikt Christopher [1 ]
Patzelt, Sebastian Berthold Maximilian [1 ,4 ]
Burkhardt, Felix [1 ]
机构
[1] Univ Freiburg, Fac Med, Ctr Dent Med, Med Ctr,Dept Prosthet Dent, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Univ Freiburg, Inst Med Biometry & Stat, Fac Med, Med Ctr, Zinkmattenstr 6a, D-79108 Freiburg, Germany
[3] Private Dent Clin, Belchenstr 6a, D-79189 Bad Krozingen, Germany
[4] Private Dent Clin, Dorfplatz 3, D-78658 Zimmern Ob Rottweil, Germany
关键词
clinical investigation; oral implant; fixed dental prosthesis; zirconia implant; prospective; LOW-TEMPERATURE DEGRADATION; SURFACE-MODIFIED ZIRCONIA; TITANIUM IMPLANTS; TISSUE-RESPONSE; FOLLOW-UP; IN-VIVO; SURVIVAL; SOFT; CLASSIFICATION; PERFORMANCE;
D O I
10.3390/jfb14010045
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective was to investigate the clinical and radiological outcome of one-piece zirconia oral implants to support three-unit fixed dental prostheses (FDP) after three years in function. Twenty-seven patients were treated with a total of 54 implants in a one-stage surgery and immediate provisionalization. Standardized radiographs were taken at implant placement, after one year and after three years, to evaluate peri-implant bone loss. Soft-tissue parameters were also assessed. Linear mixed regression models as well as Wilcoxon Signed Rank tests were used for analyzing differences between groups and time points (p < 0.05). At the three-year evaluation, one implant was lost, resulting in a cumulative survival rate of 98.1%. The mean marginal bone loss amounted to 2.16 mm. An implant success grade I of 52% (bone loss of <= 2 mm) and success grade II of 61% (bone loss of <= 3 mm) were achieved. None of the evaluated baseline parameters affected bone loss. The survival rate of the zirconia implants was comparable to market-available titanium implants. However, an increased marginal bone loss was observed with a high peri-implantitis incidence and a resulting low implant success rate.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
    Beuer, Florian
    Edelhoff, Daniel
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (04) : 445 - 451
  • [12] Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
    Florian Beuer
    Daniel Edelhoff
    Wolfgang Gernet
    John A. Sorensen
    Clinical Oral Investigations, 2009, 13 : 445 - 451
  • [13] One-Piece Zirconia Oral Implants for Single Tooth Replacement: Five-Year Results from a Prospective Cohort Study
    Kohal, Ralf-Joachim
    Burkhardt, Felix
    Chevalier, Jerome
    Patzelt, Sebastian Berthold Maximilian
    Butz, Frank
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (02)
  • [14] Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses
    Subsomboon, Chonticha
    Urapepon, Somchai
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 171 - 178
  • [15] Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants
    Spitznagel, Frank A.
    Hoppe, Johanna S.
    Bonfante, Estevam A.
    Campos, Tiago M. B.
    Langner, Robert
    Gierthmuehlen, Petra C.
    MATERIALS, 2022, 15 (23)
  • [16] Fourteen-year evaluation of posterior zirconia-based three-unit fixed dental prostheses A Prospective clinical study of all ceramic prosthesis
    Zarone, Fernando
    Di Mauro, Maria Irene
    Spagnuolo, Gianrico
    Gherlone, Enrico
    Sorrentino, Roberto
    JOURNAL OF DENTISTRY, 2020, 101
  • [17] Three-unit posterior monolithic fixed dental prostheses made from high-translucent shade-graded zirconia: 3-Year results from a prospective clinical pilot study
    Jan-Frederik Güth
    Christine Keul
    Anja Liebermann
    Josef Schweiger
    Daniel Edelhoff
    Oliver Schubert
    Clinical Oral Investigations, 29 (1)
  • [18] One-piece zirconia oral implants: one-year results from a prospective cohort study. 1. Single tooth replacement
    Kohal, Ralf-Joachim
    Knauf, Marko
    Larsson, Birgitta
    Sahlin, Herman
    Butz, Frank
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (06) : 590 - 597
  • [19] Marginal and internal fit of three-unit zirconia fixed dental prostheses: Effects of prosthesis design, cement space, and zirconia type
    Suzuki, Shohei
    Katsuta, Yasuhiro
    Ueda, Kazuhiko
    Watanabe, Fumihiko
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (04) : 460 - 467
  • [20] Ten-year outcome of three-unit fixed dental prostheses made from monolithic lithium disilicate ceramic
    Kern, Matthias
    Sasse, Martin
    Wolfart, Stefan
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2012, 143 (03): : 234 - 240