Accuracy evaluation of two portable blood glucose meters in feline patients using whole blood samples

被引:0
|
作者
Moresco, Mauricio Bianchini [1 ]
Matesco, Viviana Cauduro [2 ]
de Moura Martins, Francisco Savio [3 ]
Carvalho de Carvalho, Guilherme Luiz [3 ]
Schaefer, Gabriela da Cruz [3 ]
Nunes, Nilson Junior da Silva [3 ,4 ]
Valle, Stella de Faria [3 ,4 ,5 ]
Poppl, Alan Gomes [3 ,6 ]
机构
[1] Univ Fed Rio Grande Sul UFRGS, Hosp Clin Vet, Porto Alegre, RS, Brazil
[2] Ctr Univ Ritter Reis UniRitter, Hosp Vet, Porto Alegre, RS, Brazil
[3] Univ Fed Rio Grande Sul UFRGS, Fac Vet FaVet, Programa Posgrad Ciencias Vet, Porto Alegre, RS, Brazil
[4] Univ Fed Rio Grande Sul UFRGS, Fac Vet FaVet, Lab Anal Clin Vet, Porto Alegre, RS, Brazil
[5] Univ Fed Rio Grande Sul UFRGS, Fac Vet FaVet, Dept Patol Clin Vet, Porto Alegre, RS, Brazil
[6] Univ Fed Rio Grande Sul UFRGS, Fac Vet FaVet, Dept Med Anim, BR-91540000 Porto Alegre, RS, Brazil
来源
CIENCIA RURAL | 2023年 / 53卷 / 10期
关键词
cats; glycemia; hematocrit; portable blood glucose meters; CATS; DOGS;
D O I
10.1590/0103-8478cr20220415
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Using portable blood glucose meters (PBGMs) to measure blood glucose (BG) concentration is a common procedure in veterinary practice. Our objective was to evaluate the analytical and clinical accuracy of a human PBGM (Accu-Chek Performa (R)), (AC) and a veterinary PBGM (GlucoCalea (R)), (GC) in feline patients. Central venous blood samples were collected from 48 cats at a Brazilian Veterinary teaching hospital. Two devices from each model were used and compared to a reference method (RM). Analytical accuracy was assessed according to ISO 15197:2013 requirements for human PBGMs. Data were compared using Wilcoxon's nonparametric test and represented by Bland-Altman plots. Hematocrit's effect on BG measurements was evaluated by the Spearman correlation coefficient. Clinical accuracy was determined using error grid analysis (EGA). Values of BG were significantly higher in all PBGMs compared to the RM. Although ISO's analytical accuracy requirements could not be met by any of the devices, AC meters were more accurate than GC meters. All AC measurements -but not GC ones -were within zones A and B of the EGA, meeting ISO requirements for clinical accuracy. Significant hematocrit interference was observed in all devices. Therefore, AC showed greater accuracy compared to GC using feline whole blood samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Accuracy of portable glucose meters during the last decade:: a 24000 samples study
    Böhme, P
    Guerci, B
    Sirveaux, MA
    Floriot, M
    Durain, D
    Ziegler, O
    Drouin, P
    DIABETOLOGIA, 2002, 45 : A28 - A28
  • [32] Portable blood glucose meters as a means of monitoring blood glucose concentrations in dogs and cats with diabetes mellitus
    Stein, JE
    Greco, DS
    CLINICAL TECHNIQUES IN SMALL ANIMAL PRACTICE, 2002, 17 (02): : 70 - 72
  • [33] Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review
    Shigeaki Inoue
    Moritoki Egi
    Joji Kotani
    Kiyoshi Morita
    Critical Care, 17
  • [34] Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review
    Inoue, Shigeaki
    Egi, Moritoki
    Kotani, Joji
    Morita, Kiyoshi
    CRITICAL CARE, 2013, 17 (02)
  • [35] PORTABLE BLOOD-GLUCOSE METERS - TEACHING PATIENTS HOW TO CORRECTLY MONITOR DIABETES
    BURRITT, MF
    HANSON, E
    MUNENE, NE
    ZIMMERMAN, BR
    POSTGRADUATE MEDICINE, 1991, 89 (04) : 75 - &
  • [36] Evaluation of blood glucose meters during hypoglycemia
    Velazquez, FR
    DIABETES CARE, 1997, 20 (07) : 1204 - 1205
  • [37] EVALUATION OF BLOOD-GLUCOSE REFLECTANCE METERS
    RICHARDSON, RA
    NEW ZEALAND MEDICAL JOURNAL, 1988, 101 (855) : 643 - 643
  • [38] Evaluation of four portable blood glucose meters in diabetic and non-diabetic dogs and cats
    Kang, Min-Hee
    Kim, Do-Hyung
    Jeong, In-Seong
    Choi, Gab-Chol
    Park, Hee-Myung
    VETERINARY QUARTERLY, 2016, 36 (01) : 2 - 9
  • [39] HEMOCUE - EVALUATION OF A PORTABLE PHOTOMETRIC SYSTEM FOR DETERMINING GLUCOSE IN WHOLE-BLOOD
    ASHWORTH, L
    GIBB, I
    ALBERTI, KGMM
    CLINICAL CHEMISTRY, 1992, 38 (08) : 1479 - 1482
  • [40] Accuracy and Precision in "Class A" and "Class B" Blood Glucose Meters
    Schipper, C.
    Musholt, P. B.
    Ramljak, S.
    Knesovic, M.
    Borchert, M.
    Forst, T.
    Pfuetzner, A.
    DIABETES STOFFWECHSEL UND HERZ, 2012, 21 (03): : 151 - 155