Flow distribution in the air cooler of HTGR passive cavity cooling system

被引:4
|
作者
Qin, Haiqi [1 ]
Li, Xiaowei [1 ]
Zhang, Li [1 ]
Wu, Xinxin [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Collaborat Innovat Ctr Adv Nucl Energy Technol, Key Lab Adv Reactor Engn & Safety,Minist Educ, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
High temperature gas-cooled reactor; Passive cavity cooling system; Air cooler; Flow distribution; PARALLEL-CHANNEL CONFIGURATIONS; DIVIDING MANIFOLD SYSTEMS; PRESSURE-DROP; HEAT-EXCHANGERS; CFD SIMULATION; DESIGN; UNIFORMITY; PERFORMANCE;
D O I
10.1016/j.anucene.2022.109478
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Passive Cavity Cooling System (PCCS) is an important safety related system for High Temperature Gas-cooled Reactor (HTGR). Air cooler is one of the key components of this system. The non-uniform flow distribution is a common issue encountered in similar Parallel Tube Heat Exchanger (PTHX). Improving flow uniformity is favorable for both thermal hydraulic performance and structure safety. In this work, the flow distribution characteristics of a compact parallel tube air cooler with U-type header arrangement are theoretically and numerically investigated. First, a theoretical discrete model is proposed for flow distribution in PTHX. It reveals that the static pressure distributions in the headers are influenced by static pressure recovery, friction resistance and local pressure drop, which is directly related with flow uniformity. Then, the flow uniformity of Z-type and U-type header arrangements is numerically investigated and compared in detail. Moreover, the effects of thermal hydraulic parameter and geometrical parameter on flow uniformity are successively evaluated. Numerical results show that the flow uniformity of PCCS air cooler with U-type header arrangement is more excellent than that of Z-type header arrangement. Thermal hydraulic parameters, such as tube-side water temperature and mass flow rate, have little impact on flow uniformity. Nevertheless, the flow distribution characteristics are very sensitive to the geometrical parameters, including the insertion angle configuration, the flow area ratio of header to parallel heat transfer tubes (AR) and the cross-sectional area ratio of distribution header to collection header (DCR). Reasonable insertion angle configuration and decreasing AR can effectively enhance the flow uniformity of PCCS air cooler. For header match, it should be avoided that the distribution header diameter below the collection header diameter. As a result, the optimal structure design determined in this work is an air cooler with U-type header arrangement, where the inlet insertion angle is 0 degrees, the outlet insertion angle is 180 degrees, and the diameters of distribution header and collection header are both 120 mm. Its flow uniformity is improved by more than 50% compared with present design. This work reports a promising design modification, as the potential structure optimization for HTGR PCCS air cooler.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Study on application of heat pipe air cooler in mine cooling
    Su Zhaogui
    Zhang Anyuan
    Liu Qingzhou
    Min, Li
    3RD INTERNATIONAL SYMPOSIUM ON MODERN MINING & SAFETY TECHNOLOGY PROCEEDINGS, 2008, : 360 - 364
  • [32] FAILURE ANALYSIS OF LOSS OF HTGR CORE AUXILIARY COOLING SYSTEM
    ABDULFATTAH, AF
    HUSSEINY, AA
    ATOMKERNENERGIE-KERNTECHNIK, 1979, 34 (03): : 195 - 198
  • [33] Comparison on Safety Features among HTGR's Reactor Cavity Cooling Systems (RCCSs)
    Takamatsu, Kuniyoshi
    Funatani, Shumpei
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (03) : 832 - 845
  • [34] Optimal design of passive cooling system for the reactor lower cavity of molten salt reactor
    Mudan, Mei
    Chong, Zhou
    Yao, Fu
    Yang, Zou
    Naxiu, Wang
    He Jishu/Nuclear Techniques, 2024, 47 (08):
  • [35] EFFECT OF CROSS-FLOW ON FLOW DISTRIBUTION IN HTGR CORE COLUMN
    KABURAKI, H
    TAKIZUKA, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1987, 24 (07) : 516 - 525
  • [36] NUMERICAL SIMULATION ANALYSIS ON THE FLOW MECHANISM OF PASSIVE CONTAINMENT COOLING SYSTEM
    Song, Yang
    Li, Wei-Hua
    Li, Sheng-Qiang
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [37] Study of the Anatomical Structure of the Nasopharyngeal Cavity and Distribution of the Air Flow Field
    Tang, Yuanyuan
    Bie, Xu
    Yu, Shen
    Sun, Xiuzhen
    JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (07) : 1937 - 1941
  • [38] Two-phase flow measurements and observations in a cooling panel of the reactor cavity cooling system
    Vaghetto, R.
    Yang, S.
    Hodge, D.
    Hassan, Y.
    PROGRESS IN NUCLEAR ENERGY, 2021, 131
  • [39] Development of a PAS module in the ATHROC for simulation of passive containment air cooling system
    Zhang, Huifang
    Zheng, Yuntao
    Sun, Yanyu
    Ge, Kui
    Wu, Shihao
    Li, Yongkang
    Zhang, Yapei
    Tian, Wenxi
    Qiu, Suizheng
    Su, Guanghui
    ANNALS OF NUCLEAR ENERGY, 2025, 216
  • [40] A passive decay-heat removal system for an ABWR based on air cooling
    Mochizuki, Hiroyasu
    Yano, Takahiro
    NUCLEAR ENGINEERING AND DESIGN, 2017, 311 : 35 - 42