Dose assesment with fast Monte Carlo codes in interventional radiology

被引:1
|
作者
Balcaza, V. Garcia [1 ]
Camp, A. [1 ]
Sanchez, R. M. [2 ]
Ginjaume, M. [1 ]
Duch, M. A. [1 ]
机构
[1] Univ Politecn Catalunya UPC, Inst Tecn Energet, Ave Diagonal 647, Barcelona 08028, Spain
[2] Hosp Clin San Carlos, Fdn Invest Biomed Hosp Clin San Carlos FIBHCSC, 4 Sur,Calle Profesor Martin Lagos, Madrid 28040, Spain
关键词
D O I
10.1093/rpd/ncac244
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator. The experiments are performed in a calibration laboratory and measurements are gathered using Thermo EPD and Mirion DMC personal active dosemeters. Calculation efficiency of the fast Monte Carlo codes is approximately four orders of magnitude greater than for a standard Monte Carlo code. Satisfactory agreement between measurements and calculations is shown.
引用
收藏
页码:1813 / 1817
页数:5
相关论文
共 50 条
  • [1] Fast Monte Carlo codes for occupational dosimetry in interventional radiology
    Garcia Balcaza, V
    Camp, A.
    Badal, A.
    Andersson, M.
    Almen, A.
    Ginjaume, M.
    Duch, M. A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 166 - 174
  • [2] A parametric study of occupational radiation dose in interventional radiology by Monte-Carlo simulations
    Abdelrahman, Mahmoud
    Lombardo, Pasquale
    Camp, Anna
    Duch, Maria A.
    Phillips, Christophe
    Seret, Alain
    Vanhavere, Filip
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 58 - 70
  • [3] Monte-Carlo Dose Calculation System for Interventional Radiology (McDCIR) - Development and First Test
    Han, H.
    Moon, S.
    Son, G.
    Kim, C.
    Song, S.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E697 - E697
  • [4] Using the Monte Carlo technique to calculate dose conversion coefficients for medical professionals in interventional radiology
    Santos, W. S.
    Carvalho, A. B., Jr.
    Hunt, J. G.
    Maia, A. F.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 177 - 180
  • [5] Monte Carlo simulations of occupational radiation doses in interventional radiology
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954): : 460 - 468
  • [6] Fast skin dose estimation system for interventional radiology
    Takata, Takeshi
    Kotoku, Jun'ichi
    Maejima, Hideyuki
    Kumagai, Shinobu
    Arai, Norikazu
    Kobayashi, Takenori
    Shiraishi, Kenshiro
    Yamamoto, Masayoshi
    Kondo, Hiroshi
    Furui, Shigeru
    [J]. JOURNAL OF RADIATION RESEARCH, 2018, 59 (02) : 233 - 239
  • [7] Simultaneous determination of equivalent dose to organs and tissues of the patient and of the physician in interventional radiology using the Monte Carlo method
    Bozkurt, A.
    Bor, D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02): : 317 - 330
  • [8] Fast Monte Carlo dose calculations for brachytherapy
    Rogers, DWO
    Yegin, G
    Taylor, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S17 - S17
  • [9] Monte Carlo estimation of absorbed dose to organs in diagnostic radiology
    Alonso, M
    Barriuso, T
    Castañeda, MJ
    Díaz-Caneja, N
    Gutiérrez, I
    Sarmiento, JJ
    Villar, E
    [J]. HEALTH PHYSICS, 1999, 76 (04): : 388 - 392
  • [10] Monte Carlo Basics for Radiation Dose Assessment in Diagnostic Radiology
    Boone, John M.
    McNitt-Gray, Michael F.
    Hernandez, Andrew M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (06) : 793 - 794