Flow-based method demonstrates improved accuracy for calculating wall shear stress in arterial flows from 4D flow MRI data

被引:0
|
作者
Hurd, Elliott R. [1 ]
Iffrig, Elizabeth [2 ,3 ,4 ]
Jiang, David [1 ]
Oshinski, John N. [3 ,4 ,5 ]
Timmins, Lucas H. [1 ,6 ]
机构
[1] Univ Utah, Dept Biomed Engn, 36 S Wasatch Dr,Rm 3100, Salt Lake City, UT 84112 USA
[2] Emory Univ, Dept Med, Div Allergy Pulm Crit Care & Sleep Med, Sch Med, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[4] Emory Univ, Atlanta, GA 30332 USA
[5] Emory Univ, Dept Radiol & Imaging Sci, Sch Med, Atlanta, GA 30322 USA
[6] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Biomechanics; Cardiac MRI; Fluid-structure interaction; Hemodynamics; Phase-contrast magnetic resonance imaging; PHASE-CONTRAST MRI; BICUSPID AORTIC-VALVE; BLOOD-FLOW; VELOCITY PROFILES; HEMODYNAMICS; MECHANICS;
D O I
10.1016/j.jbiomech.2022.111413
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Four-dimensional flow magnetic resonance imaging (i.e., 4D flow MRI) has become a valuable tool for the in vivo assessment of blood flow within large vessels and cardiac chambers. As wall shear stress (WSS) has been correlated with the development and progression of cardiovascular disease, focus has been directed at devel-oping techniques to quantify WSS directly from 4D flow MRI data. The goal of this study was to compare the accuracy of two such techniques - termed the velocity and flow-based methods - in the setting of simplified and complex flow scenarios. Synthetic MR data were created from exact solutions to the Navier-Stokes equations for the steady and pulsatile flow of an incompressible, Newtonian fluid through a rigid cylinder. In addition, syn-thetic MR data were created from the predicted velocity fields derived from a fluid-structure interaction (FSI) model of pulsatile flow through a thick-walled, multi-layered model of the carotid bifurcation. Compared to the analytical solutions for steady and pulsatile flow, the flow-based method demonstrated greater accuracy than the velocity-based method in calculating WSS across all changes in fluid velocity/flow rate, tube radius, and image signal-to-noise (p < 0.001). Furthermore, the velocity-based method was more sensitive to boundary segmentation than the flow-based method. When compared to results from the FSI model, the flow-based method demonstrated greater accuracy than the velocity-based method with average differences in time-averaged WSS of 0.31 +/- 1.03 Pa and 0.45 +/- 1.03 Pa, respectively (p <0.005). These results have implications on the utility, accuracy, and clinical translational of methods to determine WSS from 4D flow MRI.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Decreased rotational flow and circumferential wall shear stress as early markers of descending aorta dilation in Marfan syndrome: a 4D flow CMR study
    A. Guala
    G. Teixido-Tura
    L. Dux-Santoy
    C. Granato
    A. Ruiz-Muñoz
    F. Valente
    L. Galian-Gay
    L. Gutiérrez
    T. González-Alujas
    K. M. Johnson
    O. Wieben
    A. Sao Avilés
    A. Evangelista
    J. Rodriguez-Palomares
    Journal of Cardiovascular Magnetic Resonance, 21
  • [42] Decreased rotational flow and circumferential wall shear stress as early markers of descending aorta dilation in Marfan syndrome: a 4D flow CMR study
    Guala, A.
    Teixido-Tura, G.
    Dux-Santoy, L.
    Granato, C.
    Ruiz-Munoz, A.
    Valente, F.
    Galian-Gay, L.
    Gutierrez, L.
    Gonzalez-Alujas, T.
    Johnson, K. M.
    Wieben, O.
    Sao Aviles, A.
    Evangelista, A.
    Rodriguez-Palomares, J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
  • [43] Abnormal left-sided blood volume, wall shear stress & energy loss in patients with repaired Tetralogy of Fallot identified by 4D flow MRI
    Ali, S. A. Ihsan
    Hudani, A. H.
    White, J. W.
    Patton, D. P.
    Greenway, S. G.
    Garcia, J. G.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1865 - 1865
  • [44] Altered ascending aortic wall shear stress in patients with corrected atrioventricular septal defect: a comprehensive cardiovascular magnetic resonance and 4D flow MRI evaluation
    Elders, Bernadette
    Westenberg, Jos
    van den Boogaard, Pieter
    Calkoen, Emmeline
    Blom, Nico
    Kroft, Lucia
    de Roos, Albert
    Roest, Arno
    CARDIOLOGY IN THE YOUNG, 2019, 29 (05) : 637 - 642
  • [45] Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers
    van der Palen, Roel L. F.
    Roest, Arno A. W.
    van den Boogaard, Pieter J.
    de Roos, Albert
    Blom, Nico A.
    Westenberg, Jos J. M.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (05) : 653 - 663
  • [46] Towards Cerebral Aneurysm Rupture Risk Prediction Using Quantitative Analysis by 4D Flow MRI: Intra-Aneurysmal Vortical Blood Flow and Association to Wall Shear Stress.
    Elbaz, Mohammed S.
    Aristova, Maria
    Ma, Liliana
    Vali, Alireza
    Bollache, Emilie
    Barker, Alex J.
    Hurley, Michael C.
    Potts, Matthew B.
    Jahromi, Babak S.
    Ansari, Sameer A.
    Markl, Michael
    Schnell, Susanne
    STROKE, 2019, 50
  • [47] Evaluation of 3D blood flow patterns and wall shear stress in the normal and dilated thoracic aorta using flow-sensitive 4D CMR
    Jonas Bürk
    Philipp Blanke
    Zoran Stankovic
    Alex Barker
    Maximilian Russe
    Julia Geiger
    Alex Frydrychowicz
    Mathias Langer
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 14
  • [48] Evaluation of 3D blood flow patterns and wall shear stress in the normal and dilated thoracic aorta using flow-sensitive 4D CMR
    Buerk, Jonas
    Blanke, Philipp
    Stankovic, Zoran
    Barker, Alex
    Russe, Maximilian
    Geiger, Julia
    Frydrychowicz, Alex
    Langer, Mathias
    Markl, Michael
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [49] 4D Flow MRI-Based Pressure Loss Estimation in Stenotic Flows: Evaluation Using Numerical Simulations
    Casas, Belen
    Lantz, Jonas
    Dyverfeldt, Petter
    Ebbers, Tino
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1808 - 1821
  • [50] Wall shear stress in outflow tract premature ventricular contraction location assessed through 4D-flow MRI
    Chevance, Virgile
    Azarine, Arshid
    Hamon, David A.
    Dhanjal, Tarvinder S.
    Teiger, Emmanuel
    Deux, Jean-Francois
    Lellouche, Nicolas
    EUROPACE, 2024, 26 (02):