Flow-based method demonstrates improved accuracy for calculating wall shear stress in arterial flows from 4D flow MRI data

被引:0
|
作者
Hurd, Elliott R. [1 ]
Iffrig, Elizabeth [2 ,3 ,4 ]
Jiang, David [1 ]
Oshinski, John N. [3 ,4 ,5 ]
Timmins, Lucas H. [1 ,6 ]
机构
[1] Univ Utah, Dept Biomed Engn, 36 S Wasatch Dr,Rm 3100, Salt Lake City, UT 84112 USA
[2] Emory Univ, Dept Med, Div Allergy Pulm Crit Care & Sleep Med, Sch Med, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[4] Emory Univ, Atlanta, GA 30332 USA
[5] Emory Univ, Dept Radiol & Imaging Sci, Sch Med, Atlanta, GA 30322 USA
[6] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Biomechanics; Cardiac MRI; Fluid-structure interaction; Hemodynamics; Phase-contrast magnetic resonance imaging; PHASE-CONTRAST MRI; BICUSPID AORTIC-VALVE; BLOOD-FLOW; VELOCITY PROFILES; HEMODYNAMICS; MECHANICS;
D O I
10.1016/j.jbiomech.2022.111413
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Four-dimensional flow magnetic resonance imaging (i.e., 4D flow MRI) has become a valuable tool for the in vivo assessment of blood flow within large vessels and cardiac chambers. As wall shear stress (WSS) has been correlated with the development and progression of cardiovascular disease, focus has been directed at devel-oping techniques to quantify WSS directly from 4D flow MRI data. The goal of this study was to compare the accuracy of two such techniques - termed the velocity and flow-based methods - in the setting of simplified and complex flow scenarios. Synthetic MR data were created from exact solutions to the Navier-Stokes equations for the steady and pulsatile flow of an incompressible, Newtonian fluid through a rigid cylinder. In addition, syn-thetic MR data were created from the predicted velocity fields derived from a fluid-structure interaction (FSI) model of pulsatile flow through a thick-walled, multi-layered model of the carotid bifurcation. Compared to the analytical solutions for steady and pulsatile flow, the flow-based method demonstrated greater accuracy than the velocity-based method in calculating WSS across all changes in fluid velocity/flow rate, tube radius, and image signal-to-noise (p < 0.001). Furthermore, the velocity-based method was more sensitive to boundary segmentation than the flow-based method. When compared to results from the FSI model, the flow-based method demonstrated greater accuracy than the velocity-based method with average differences in time-averaged WSS of 0.31 +/- 1.03 Pa and 0.45 +/- 1.03 Pa, respectively (p <0.005). These results have implications on the utility, accuracy, and clinical translational of methods to determine WSS from 4D flow MRI.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Accuracy and Inter observer variability of blood flow quantification on 4D flow MRI in adult with transposition of the great arteries corrected by arterial switch
    Zahra Belhajer
    Gilles Soulat
    Arshid Azarine
    Florence Pontnau
    Magalie Ladouceur
    Damien Bonnet
    Laurence Iserin
    Elie Mousseaux
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [32] Quantification of Oscillatory Shear Stress from Reciprocating CSF Motion on 4D Flow Imaging
    Yamada, S.
    Ito, H.
    Ishikawa, M.
    Yamamoto, K.
    Yamaguchi, M.
    Oshima, M.
    Nozaki, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (03) : 479 - 486
  • [33] Improved Flow-Based Travel Time Estimation Method from Point Detector Data for Freeways
    Vanajakshi, Lelitha D.
    Williams, Billy M.
    Rilett, Laurence R.
    JOURNAL OF TRANSPORTATION ENGINEERING, 2009, 135 (01) : 26 - 36
  • [34] Expanding the volume on 4D flow CMR Editorial for "Robustness of 4D flow MRI derived aortic wall shear stress and pulse wave velocity across different protocols in healthy controls and in patients with bicuspid aortic valve"
    Fischer, Kady
    Bastiaansen, Jessica A. M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2025, 41 (02): : 181 - 183
  • [35] Scan–rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers
    Roel L. F. van der Palen
    Arno A. W. Roest
    Pieter J. van den Boogaard
    Albert de Roos
    Nico A. Blom
    Jos J. M. Westenberg
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 653 - 663
  • [36] A comparison of 4D flow MRI-derived wall shear stress with computational fluid dynamics methods for intracranial aneurysms and carotid bifurcations - A review
    Szajer, Jeremy
    Ho-Shon, Kevin
    MAGNETIC RESONANCE IMAGING, 2018, 48 : 62 - 69
  • [37] Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
    E. S. Farag
    J. Vendrik
    P. van Ooij
    Q. L. Poortvliet
    F. van Kesteren
    L. W. Wollersheim
    A. Kaya
    A. H. G. Driessen
    J. J. Piek
    K. T. Koch
    J. Baan
    R. N. Planken
    J. Kluin
    A. J. Nederveen
    B. A. J. M. de Mol
    European Radiology, 2019, 29 : 1444 - 1451
  • [38] Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
    Farag, E. S.
    Vendrik, J.
    van Ooij, P.
    Poortvliet, Q. L.
    van Kesteren, F.
    Wollersheim, L. W.
    Kaya, A.
    Driessen, A. H. G.
    Piek, J. J.
    Koch, K. T.
    Baan, J.
    Planken, R. N.
    Kluin, J.
    Nederveen, A. J.
    de Mol, B. A. J. M.
    EUROPEAN RADIOLOGY, 2019, 29 (03) : 1444 - 1451
  • [39] An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing
    Ehrhardt, Jan
    Werner, Rene
    Saering, Dennis
    Frenzel, Thorsten
    Lu, Wei
    Low, Daniel
    Handels, Heinz
    MEDICAL PHYSICS, 2007, 34 (02) : 711 - 721
  • [40] IMPROVED VISUALIZATION AND QUANTIFICATION OF 4D FLOW MRI DATA USING DIVERGENCE-FREE WAVELET DENOISING
    Ong, F.
    Uecker, M.
    Tariq, U.
    Hsiao, A.
    Alley, M. T.
    Vasanawala, S. S.
    Lustig, M.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1186 - 1189