Flow-based method demonstrates improved accuracy for calculating wall shear stress in arterial flows from 4D flow MRI data

被引:0
|
作者
Hurd, Elliott R. [1 ]
Iffrig, Elizabeth [2 ,3 ,4 ]
Jiang, David [1 ]
Oshinski, John N. [3 ,4 ,5 ]
Timmins, Lucas H. [1 ,6 ]
机构
[1] Univ Utah, Dept Biomed Engn, 36 S Wasatch Dr,Rm 3100, Salt Lake City, UT 84112 USA
[2] Emory Univ, Dept Med, Div Allergy Pulm Crit Care & Sleep Med, Sch Med, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[4] Emory Univ, Atlanta, GA 30332 USA
[5] Emory Univ, Dept Radiol & Imaging Sci, Sch Med, Atlanta, GA 30322 USA
[6] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Biomechanics; Cardiac MRI; Fluid-structure interaction; Hemodynamics; Phase-contrast magnetic resonance imaging; PHASE-CONTRAST MRI; BICUSPID AORTIC-VALVE; BLOOD-FLOW; VELOCITY PROFILES; HEMODYNAMICS; MECHANICS;
D O I
10.1016/j.jbiomech.2022.111413
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Four-dimensional flow magnetic resonance imaging (i.e., 4D flow MRI) has become a valuable tool for the in vivo assessment of blood flow within large vessels and cardiac chambers. As wall shear stress (WSS) has been correlated with the development and progression of cardiovascular disease, focus has been directed at devel-oping techniques to quantify WSS directly from 4D flow MRI data. The goal of this study was to compare the accuracy of two such techniques - termed the velocity and flow-based methods - in the setting of simplified and complex flow scenarios. Synthetic MR data were created from exact solutions to the Navier-Stokes equations for the steady and pulsatile flow of an incompressible, Newtonian fluid through a rigid cylinder. In addition, syn-thetic MR data were created from the predicted velocity fields derived from a fluid-structure interaction (FSI) model of pulsatile flow through a thick-walled, multi-layered model of the carotid bifurcation. Compared to the analytical solutions for steady and pulsatile flow, the flow-based method demonstrated greater accuracy than the velocity-based method in calculating WSS across all changes in fluid velocity/flow rate, tube radius, and image signal-to-noise (p < 0.001). Furthermore, the velocity-based method was more sensitive to boundary segmentation than the flow-based method. When compared to results from the FSI model, the flow-based method demonstrated greater accuracy than the velocity-based method with average differences in time-averaged WSS of 0.31 +/- 1.03 Pa and 0.45 +/- 1.03 Pa, respectively (p <0.005). These results have implications on the utility, accuracy, and clinical translational of methods to determine WSS from 4D flow MRI.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Automated vortical blood flow-based estimation of mean pulmonary arterial pressure from 4D flow MRI
    Kraeuter, Corina
    Reiter, Ursula
    Kovacs, Gabor
    Reiter, Clemens
    Masana, Marc
    Olschewski, Horst
    Fuchsjaeger, Michael
    Stollberger, Rudolf
    Reiter, Gert
    MAGNETIC RESONANCE IMAGING, 2022, 88 : 132 - 141
  • [2] Normal values of wall shear stress in the pulmonary artery from 4D flow data
    Julio A Sotelo
    Pablo Bächler
    Steren Chabert
    Daniel Hurtado
    Pablo Irarrazaval
    Cristian Tejos
    Sergio Uribe
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [3] 3D axial and circumferential wall shear stress from 4D flow MRI data using a finite element method and a laplacian approach
    Sotelo, Julio
    Dux-Santoy, Lydia
    Guala, Andrea
    Rodriguez-Palomares, Jose
    Evangelista, Arturo
    Sing-Long, Carlos
    Urbina, Jesus
    Mura, Joaquin
    Hurtado, Daniel E.
    Uribe, Sergio
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2816 - 2823
  • [4] Towards quantitative evaluation of wall shear stress from 4D flow imaging
    Levilly, Sebastien
    Castagna, Marco
    Idier, Jerome
    Bonnefoy, Felicien
    Le Touze, David
    Moussaoui, Said
    Paul-Gilloteaux, Perrine
    Serfaty, Jean-Michel
    MAGNETIC RESONANCE IMAGING, 2020, 74 : 232 - 243
  • [5] WSSNet: Aortic Wall Shear Stress Estimation Using Deep Learning on 4D Flow MRI
    Ferdian, Edward
    Dubowitz, David J.
    Mauger, Charlene A.
    Wang, Alan
    Young, Alistair A.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [6] Wall Shear Stress Estimation for 4D Flow MRI Using Navier–Stokes Equation Correction
    Jiacheng Zhang
    Sean M. Rothenberger
    Melissa C. Brindise
    Michael Markl
    Vitaliy L. Rayz
    Pavlos P. Vlachos
    Annals of Biomedical Engineering, 2022, 50 : 1810 - 1825
  • [7] Characterization of Abnormal Wall Shear Stress Using 4D Flow MRI in Human Bicuspid Aortopathy
    Pim van Ooij
    Wouter V. Potters
    Jeremy Collins
    Maria Carr
    James Carr
    S. Chris Malaisrie
    Paul W. M. Fedak
    Patrick M. McCarthy
    Michael Markl
    Alex J. Barker
    Annals of Biomedical Engineering, 2015, 43 : 1385 - 1397
  • [8] Characterization of Abnormal Wall Shear Stress Using 4D Flow MRI in Human Bicuspid Aortopathy
    van Ooij, Pim
    Potters, Wouter V.
    Collins, Jeremy
    Carr, Maria
    Carr, James
    Malaisrie, S. Chris
    Fedak, Paul W. M.
    McCarthy, Patrick M.
    Markl, Michael
    Barker, Alex J.
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (06) : 1385 - 1397
  • [9] ESTIMATION OF WALL SHEAR STRESS USING 4D FLOW CARDIOVASCULAR MRI AND COMPUTATIONAL FLUID DYNAMICS
    Soudah, E.
    Casacuberta, J.
    Gamez-Montero, P. J.
    Perez, J. S.
    Rodriguez-Cancio, M.
    Raush, G.
    Li, C. H.
    Carreras, F.
    Castilla, R.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [10] Quantification and comparison of 4D Flow MRI derived wall shear stress and MRE derived wall shear stiffness of abdominal aorta
    Venkata Sita Priyanka Illapani
    Julio Garcia
    Ria Mazumder
    Richard D White
    Michael Markl
    Arunark Kolipaka
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)