High-precision measurement of Cd isotopes in ultra-trace Cd samples using double spike-standard addition MC-ICP-MS

被引:0
|
作者
Chang, Hui [1 ]
Zhu, Jian-Ming [1 ,3 ]
Wang, Xiangli [2 ]
Gao, Ting [3 ]
机构
[1] China Univ Geosci Beijing, State Key Lab Geol Proc & Mineral Resources, Beijing 100083, Peoples R China
[2] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Cenozo Geol & Environm, Beijing 100029, Peoples R China
[3] Chinese Acad Sci, Inst Geochem, State Key Lab Environm Geochem, Guiyang 550081, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM; FRACTIONATION; LIVER; SOIL; GEOCHEMISTRY; PERSPECTIVES; BIVALVES; SEAWATER; OCEAN;
D O I
10.1039/d3ja00047h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The double spike-standard addition (DSSA) is a powerful method proposed for isotope measurement of ultra-trace elements in samples. Here, we test the method's practicality and robustness for obtaining high-precision delta Cd-114/110 data in samples with complex matrices and ultra-trace cadmium (Cd) concentrations as low as 0.004 mu g g(-1). Through a DS data reduction routine and isotope binary mixing model, the delta Cd-114/110 values obtained for numeral geological and biological reference materials (GRMs/BRMs) agree well with certified or previous measurements, even for similar to 2.1 ng Cd of BCR-2. The overall precision of both single- and multi-standard addition depends on the sample fraction (f(spl)) owing to the error propagation. And 0.041 +/- 0.022 parts per thousand (2SD, n = 46) of precision for delta Cd-114/110 can be achieved when the sample fraction (f(spl)) is >= 20%, comparable to 0.056 +/- 0.039 parts per thousand (2SD, n = 23) obtained by the traditional DS method. However, it becomes greater than 0.110 parts per thousand when f(spl) is <20%, indicating that 20% (1/5) -50% (1/2) of f(spl) is the optimal mixing range to obtain high-precision data if the minimal sample sizes are required. These further confirm that accurate and precise Cd isotope ratios can be determined by DSSA. Correspondingly, the purification scheme can be simplified to a single column due to the added standard solution boosting analyte and diluting ratios of matrix/Cd. Animal organs, with 0.004-0.106 mu g g(-1) Cd, yield large variations of delta Cd-114/110 (-0.054 +/- 0.030 parts per thousand (2SD, n = 4) and 0.681 +/- 0.022 parts per thousand (2SD, n = 4) for ovine liver and kidney, respectively), suggesting that Cd isotopes can be fractionated significantly during biological metabolic processes and may be a potential use in medical diagnosis. Robust measurement of Cd isotope composition in ultra-trace Cd samples with complex matrices by DSSA broadens the scope of measurable samples by the traditional DS method, thus potentially opening a range of new opportunities in life, agricultural, environmental, and earth/planetary sciences.
引用
收藏
页码:950 / 962
页数:13
相关论文
共 50 条
  • [21] Improvement in the chemical separation and determination of uncertainties for bulk analysis of Pu isotopes at ultra-trace levels by using MC-ICP-MS
    Sang Ho Lim
    Jinkyu Park
    Sun-Ho Han
    Ranhee Park
    Chi-Gyu Lee
    Jong-Ho Park
    Kyuseok Song
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 1853 - 1859
  • [22] High-precision analysis of calcium isotopes using a Nu Sapphire collision cell (CC)-MC-ICP-MS
    Gao, Bing-Yu
    Su, Ben-Xun
    Li, Wen-Jun
    Yuan, Meng
    Sun, Jian
    Zhao, Ye
    Liu, Xia
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (10) : 2111 - 2121
  • [23] Validation of Bulk Analysis with Simulated Swipe Samples Containing Ultra-Trace Amounts of Uranium and Plutonium Using MC-ICP-MS
    Lim, Sang Ho
    Han, Sun-Ho
    Park, Jong-Ho
    Park, Ranhee
    Lee, Min Young
    Park, Jinkyu
    Lee, Chi-Gyu
    Song, Kyuseok
    [J]. MASS SPECTROMETRY LETTERS, 2015, 6 (03) : 75 - 79
  • [24] Optimization of the sample preparation and measurement protocol for the analysis of uranium isotopes by MC-ICP-MS without spike addition
    Rovan, Leja
    Strok, Marko
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1882 - 1891
  • [25] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479
  • [26] High-precision copper isotopic analysis using a Nu Sapphire MC-ICP-MS
    Wang, Jing
    Su, Ben-Xun
    Tang, Dong-Mei
    Yuan, Qing-Han
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2589 - 2598
  • [27] High-precision lithium isotopic analysis using the Nu Sapphire MC-ICP-MS
    Liu, Shanke
    Li, Wenjun
    Su, Benxun
    Gao, Bingyu
    Wang, Jing
    Wang, Changle
    Luo, Yang
    Yan, Lizhi
    Zhao, Ye
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 656 - 666
  • [28] High precision potassium isotope analysis of geological samples using MC-ICP-MS
    Chen Y.
    Sun H.
    Gu H.
    Huang C.
    Cao Z.
    Wang F.
    Ge C.
    [J]. Dizhi Xuebao/Acta Geologica Sinica, 2023, 97 (04): : 1360 - 1370
  • [29] High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS
    Peng, Huan
    He, Dong
    Guo, Rui
    Liu, Xing
    Belshaw, Nicholas S.
    Zheng, Hongtao
    Hu, Shenghong
    Zhu, Zhenli
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (02) : 390 - 398
  • [30] High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket
    Li, Ming
    Lei, Yv
    Feng, Lanping
    Wang, Zaicong
    Belshaw, Nick S.
    Hu, Zhaochu
    Liu, Yongsheng
    Zhou, Lian
    Chen, Haihong
    Chai, Xinna
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) : 1707 - 1719