Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

被引:1
|
作者
Kashy, D. [1 ]
Gopinath, S. [1 ]
Sun, E. [1 ]
Ghoshal, P. [1 ]
Fast, J. [1 ]
Sinnott, M. [2 ]
Lamont, J. [1 ]
Dion, M. P. [1 ]
Fair, R. [1 ]
Kumar, K. [3 ]
Mammei, J. [4 ]
Rajput-Ghoshal, R. [1 ]
Ihloff, E. [5 ]
机构
[1] Jefferson Lab, Newport News, VA 23606 USA
[2] Everson Tesla Inc, Nazareth, PA 18064 USA
[3] Univ Massachusetts, Amherst, MA 01003 USA
[4] Univ Manitoba, Winnipeg, MB R3T 2N2, Canada
[5] MIT, Cambridge, MA 02139 USA
关键词
Epoxy; radiation; spectrometer; toroid; vacuum; water-cooled; RESIN;
D O I
10.1109/TASC.2023.3337065
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment- Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)-requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Moller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). This article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [41] Novel rapid control prototyping for permanent magnet synchronous motor via model-based design and STM32 chip
    Hu, Mingyuan
    Ahn, Hyeongki
    Park, Jihoon
    You, Kwanho
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2024, 135 (3-4): : 1187 - 1204
  • [42] Development of a novel cross-axis countercurrent chromatographic instrument with six separation columns: Design, dynamics, optimization, prototyping, and experiment
    Zhao, Yongjie
    Zhang, Xiping
    Luo, Tiexuan
    Zou, Dejin
    Yuan, Haihua
    Liu, Zhicong
    Liu, Yang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (11):
  • [43] Novel Vacuum Vessel & Coil System Design for the Advanced Divertor Experiment (ADX)
    Vieira, R. F.
    Doody, J.
    Beck, W. K.
    Zhou, L.
    Leccacorvi, R.
    LaBombard, B.
    Granetz, R. S.
    Wolfe, S. M.
    Irby, J. H.
    Wukitch, S. J.
    Terry, D. R.
    Wallace, G. M.
    Parker, R. R.
    2015 IEEE 26TH SYMPOSIUM ON FUSION ENGINEERING (SOFE), 2015,
  • [44] Design, Simulation and Experiment of a Novel Mass Detection System with Active Control Magnetic
    Xiao, Qijun
    Liu, Chaoyin
    Son, Hungsun
    Guo, Jinjun
    Li, Shengyong
    Li, Jian
    2012 12TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS & VISION (ICARCV), 2012, : 1120 - 1124
  • [45] System design and animal experiment study of a novel minimally invasive surgical robot
    Wang, Wei
    Li, Jianmin
    Wang, Shuxin
    Su, He
    Jiang, Xueming
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (01): : 73 - 84
  • [46] Design and practice of a novel experiment teaching system based on the optoelectronic information chain
    Luo, Yunhan
    Chen, Zhe
    Li, Yan
    Di, Hongwei
    Li, Zhen
    Bai, Chunhe
    Tang, Jieyuan
    Zhang, Jun
    Xiao, Yi
    14TH CONFERENCE ON EDUCATION AND TRAINING IN OPTICS AND PHOTONICS (ETOP 2017), 2017, 10452
  • [47] Design and experiment of a novel analogue phase locked system for interferometric fiber sensors
    Optoelectronic Information Science and Technology Laboratory, Institute of Modern Optics, Nankai University, Tianjin 300071, China
    Guangdianzi Jiguang, 2007, 4 (428-431): : 428 - 431
  • [48] Design and initial operation of a two-color soft x-ray camera system on the Compact Toroidal Hybrid experiment
    Herfindal, J. L.
    Dawson, J. D.
    Ennis, D. A.
    Hartwell, G. J.
    Loch, S. D.
    Maurer, D. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [49] Analysis and Design of a Novel Outer Mover Moving Magnet Linear Oscillating Actuator for a Refrigeration System
    Ahmad, Zahoor
    Hassan, Adnan
    Khan, Faisal
    Ahmad, Naseer
    Khan, Bakhtiar
    Ro, Jong-Suk
    IEEE ACCESS, 2021, 9 : 121240 - 121252
  • [50] Design and Analysis of Novel Bearingless Permanent Magnet Synchronous Motor for Flywheel Energy Storage System
    Zhu, Huangqiu
    Lu, Ronghua
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2016, 51 : 147 - 156