Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

被引:1
|
作者
Kashy, D. [1 ]
Gopinath, S. [1 ]
Sun, E. [1 ]
Ghoshal, P. [1 ]
Fast, J. [1 ]
Sinnott, M. [2 ]
Lamont, J. [1 ]
Dion, M. P. [1 ]
Fair, R. [1 ]
Kumar, K. [3 ]
Mammei, J. [4 ]
Rajput-Ghoshal, R. [1 ]
Ihloff, E. [5 ]
机构
[1] Jefferson Lab, Newport News, VA 23606 USA
[2] Everson Tesla Inc, Nazareth, PA 18064 USA
[3] Univ Massachusetts, Amherst, MA 01003 USA
[4] Univ Manitoba, Winnipeg, MB R3T 2N2, Canada
[5] MIT, Cambridge, MA 02139 USA
关键词
Epoxy; radiation; spectrometer; toroid; vacuum; water-cooled; RESIN;
D O I
10.1109/TASC.2023.3337065
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment- Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)-requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Moller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). This article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [31] Optimal design of a toroidal field magnet system and cost of electricity implications for a tokamak using high temperature superconductors
    Lee, T. S.
    Jenkins, I.
    Surrey, E.
    Hampshire, D. P.
    FUSION ENGINEERING AND DESIGN, 2015, 98-99 : 1072 - 1075
  • [32] A novel, cost-effective, multi-point Thomson scattering system on the Pegasus Toroidal Experiment
    Schlossberg, D. J.
    Bodner, G. M.
    Bongard, M. W.
    Fonck, R. J.
    Reusch, J. A.
    Sanchez, C. Rodriguez
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [33] Laser marking system for light guide panel using design of experiment and web-based prototyping
    Kang, Hyuk-Jin
    Kim, Hyung-Jung
    Kim, Ji-Seok
    Choi, Woon-Yong
    Chu, Won-Shik
    Ahn, Sung-Hoon
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2010, 26 (05) : 535 - 540
  • [34] Research on a Novel Arresting System for Escape Ramps: Design and Experiment
    Xu, Xiuchen
    Zhang, Hongchao
    Du, Xiaobo
    Zhao, Xianpeng
    JOURNAL OF TRANSPORTATION ENGINEERING PART A-SYSTEMS, 2024, 150 (03)
  • [35] A Novel Design of Multi-Coil Pulsed Magnet System for 100 T
    Peng, T.
    Liu, S. B.
    Pan, Y.
    Lv, Y. L.
    Ding, H. F.
    Han, X. T.
    Xiao, H. X.
    Wang, S.
    Jiang, S.
    Li, L.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2022, 32 (06)
  • [36] Mechatronics system design and experiment research for a novel patient transfer apparatus
    Wang, Hongbo
    Xie, Liyu
    Zhao, Xiong
    Niu, Jianye
    Liu, Zhengcao
    Vladareanu, Luige
    Mihai, Razvan-Viorel
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MECHATRONICS, ROBOTICS AND AUTOMATION (ICMRA 2015), 2015, 15 : 1140 - 1143
  • [37] DESIGN AND EXPERIMENT OF A NOVEL 4-DOF VIBRATION ISOLATING SYSTEM
    Wei, Baochen
    Yue, Yi
    Zhao, Xianchao
    Li, Yanbiao
    Qi, Chenkun
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2022, 37 (02): : 182 - 191
  • [38] Design of Novel X-ray Optical System for Rocket Experiment
    Pina, L.
    Hudec, R.
    Tichy, V.
    Inneman, A.
    Cerna, D.
    Sveda, L.
    Marsik, J.
    Marsikova, V.
    Cash, W.
    Shipley, A. F.
    Zeiger, B. R.
    Rogers, T. D.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VIII, 2013, 8848
  • [39] Design and Experiment of 100kW Interior Permanent Magnet Machine for Ship Anti Heeling System
    Lee, Sun-Kwon
    Kang, Gyu-Hong
    Hur, Jin
    Kim, Byoung-Woo
    2012 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2012, : 544 - 548
  • [40] Design of the Superconducting Magnet System for the New g-2/EDM Experiment in the J-PARC
    Sasaki, Ken-ichi
    Abe, Mitsushi
    Iinuma, Hiromi
    Mibe, Tsutomu
    Oyama, Shun
    Saito, Naohito
    Ando, Ryuya
    Chiba, Tomoo
    Koga, Tomoyuki
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)