Comparison of bite force evaluation for mandibular angle fracture fixation by conventional miniplates versus new design miniplates: a clinical study

被引:0
|
作者
Gamit, Mruga [1 ]
Patel, Yashesh [1 ]
Sood, Ramita [1 ]
Vadera, Hitesh [1 ]
Savjani, Kinjal [2 ]
Bhatti, Zenish [1 ]
机构
[1] Ahmedabad Municipal Corp Dent Coll & Hosp, Dept Oral & Maxillofacial Surg, Ahmadabad, India
[2] Ahmedabad Municipal Corp Dent Coll & Hosp, Dept Periodontol, Ahmadabad, India
来源
关键词
Mandibular angle fractures; Conventional miniplates; New design miniplates; Bite force; Masticatory efficiency; TITANIUM MINIPLATE; OSTEOSYNTHESIS; PATTERNS; PLATES; 5-YEAR;
D O I
10.1007/s10006-023-01182-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeTo evaluate postoperative masticatory efficacy of a new design non-compression titanium miniplate compared to conventional non-compression titanium miniplate on the basis of bite force for treatment of mandibular angle fractures.MethodologyThe prospective study included 20 patients with mandibular angle fractures randomly categorized into 2 groups: Group I, fixation of angle fractures by conventional miniplates, and Group II, fixation of angle fractures by new design miniplates. Evaluation was done for clinical outcome, primarily bite force; radiological outcome; and associated postoperative morbidities at different time intervals.ResultsThe results showed to be highly significant in terms of mean operating time for plate adaptation and fixation and bite force adaptation (p = 0.003 at follow-up of 6 months) for the newer miniplate compared to the conventional miniplate. No statistically significant difference was seen for postoperative paresthesia, malunion, non-union, occlusal discrepancy, or hardware failure.ConclusionWithin the limits of the study, it appears that the single, monocortical, non-compression, superior border new design miniplate proved to be a successful procedure for treating non-comminuted mandibular angle fractures specifically in terms of enhanced postoperative masticatory efficiency as compared to conventional miniplates. Further clinical studies with larger sample size can derive a more comprehensive conclusion.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
  • [41] Comparison between three-dimensional and standard miniplates in the management of mandibular angle fractures: a prospective, randomized, double-blind, controlled clinical study
    Al-Moraissi, E. A.
    Mounair, R. M.
    El-Sharkawy, T. M.
    El-Ghareeb, T. I.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (03) : 316 - 321
  • [42] Conventional 2D miniplate versus 3D four-holed and eight-holed miniplates in the management of mandibular angle fractures
    Yadav, Sandeep
    Mohanty, Sujata
    Sharma, Pankaj
    Kohli, Sanchaita
    Singh, Chandravir
    Dabas, Jitender
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2020, 32 (05) : 336 - 341
  • [43] A Comparative Evaluation of Fixation Techniques in Anterior Mandibular Fractures Using 2.0 mm Monocortical Titanium Miniplates Versus 2.4 mm Cortical Titanium Lag Screws
    Goyal M.
    Jhamb A.
    Chawla S.
    Marya K.
    Dua J.S.
    Yadav S.
    Journal of Maxillofacial and Oral Surgery, 2012, 11 (4) : 442 - 450
  • [44] Evaluation of the Effect of Phototherapy in Patients with Mandibular Fracture on Mandibular Dynamics, Pain, Edema, and Bite Force: A Pilot Study
    Lauriti, Leandro
    de Cerqueira Luz, Joao Gualberto
    Agnelli Mesquita-Ferrari, Raquel
    Santos Fernandes, Kristianne Porta
    Deana, Alessandro Melo
    Ratto Tempestini Horliana, Anna Carolina
    Costa-Santos, Larissa
    Brugnera Junior, Aldo
    Bussadori, Sandra Kalil
    PHOTOMEDICINE AND LASER SURGERY, 2018, 36 (01) : 24 - 30
  • [45] CLINICAL AND IN-VITRO EVALUATION OF MANDIBULAR ANGLE FRACTURE FIXATION WITH THE 2-MINIPLATE SYSTEM
    CHOI, BH
    KIM, KN
    KANG, HS
    DO, KW
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 79 (06): : 692 - 695
  • [46] Transoral Miniplate Fixation of Mandibular Angle Fracture with and without 2 Weeks of Maxillomandibular Fixation: A Clinical Trial Study
    Khiabani, Kazem S.
    Mehmandoost, Meghdad Khanian
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2013, 6 (02) : 107 - 113
  • [47] Comparison of Intermaxillary Fixation Screw Versus Eyelet Interdental Wiring for Intermaxillary Fixation in Minimally Displaced Mandibular Fracture: A Randomized Clinical Study
    Ingole, Pranav D.
    Garg, Anoop
    Shenoi, S. Ramakrishna
    Badjate, Samprati J.
    Budhraja, Nilima
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 72 (05) : 958.e1 - 958.e7
  • [48] Comparison Between Conventional Titanium Miniplates and Indigenous Detachable Custom made 3D Titanium Plates (VAS 3D Bone Plate) for Fixation of Mandibular Fracture in Mental Foramen Region: A Randomized Clinical Trial and Finite Element Analysis
    Sanchita Thapliyal
    Apoorva Mowar
    Vishal Bansal
    Journal of Maxillofacial and Oral Surgery, 2022, 21 : 211 - 218
  • [49] Comparison Between Conventional Titanium Miniplates and Indigenous Detachable Custom made 3D Titanium Plates (VAS 3D Bone Plate) for Fixation of Mandibular Fracture in Mental Foramen Region: A Randomized Clinical Trial and Finite Element Analysis
    Thapliyal, Sanchita
    Mowar, Apoorva
    Bansal, Vishal
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2022, 21 (01): : 211 - 218
  • [50] New design titanium miniplate in mandibular angle fracture treatment: a biomechanical study
    Tugce Simsek
    Mehmet Mustafa Erdogan
    Levent Ugur
    Hasan Kazaz
    Erkan Tezcan
    Sinan Seyhan
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43