Experimental and numerical studies of improving cyclic behavior of infilled reinforced concrete frame by prefabricated wall panels with sliding joints

被引:8
|
作者
Zhang, Chao [1 ]
Yang, Zheng [1 ]
Yu, Tianhao [1 ]
Huang, Weiyuan [1 ,2 ,3 ,5 ]
Deng, Xuesong [1 ]
Lin, Zexin [1 ]
Wu, Siyuan [4 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Peoples R China
[2] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
[3] Politecn Milan, Dipartimento Ingn Civile Ambientale, I-20133 Milan, Italy
[4] China Construct Eighth Engn Div Co Ltd, Shanghai 200122, Peoples R China
[5] 1239 Siping Rd, Shanghai, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Seismic performance; Reinforced concrete frame; Prefabricated wall panel; Sliding joint; Infill-frame interaction; STEEL FRAMES; MASONRY INFILLS; BUILDINGS; RETROFIT; LAQUILA;
D O I
10.1016/j.jobe.2023.107524
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper aims to introduce a new type of damping infill wall system to alleviate the negative infill-frame interaction of fragile infill walls for reinforced concrete (RC) frames and improve the cyclic behaviors of the entire system. Three tested specimens including specimen BF (a bare RC frame), specimen CWF (an RC frame with ordinary infill walls), and specimen DWF (an RC frame with novel damping infill walls) are designed and fabricated. Quasi-static cyclic tests are conducted to them for exploring and comparing their cyclic behaviors. Experimental results reveal that severe destruction appears upon the conventional infill walls due to the negative infill-frame interaction. On the contrary, no significant cracks or damage are viewed in the new damping wall panels at the inter-story drift ratio of 4.00%. It confirms that the unfavorable infill-frame interaction under horizontal loadings can be mitigated by the developed damping infill systems effectively. The developed innovative infilled RC frame and the bare RC frame exhibit similar cyclic behaviors, including the hysteretic response, loading capacity deterioration, secant stiffness deterioration, and displacement ductility. Furthermore, by using the advanced infill wall system, the RC frame can dissipate energy more efficiently by over 15.71% and ameliorate the degradation of energy dissipation capacity through the stable damping force from the sliding joints. Additionally, numerical models and specimens show similar cyclic behaviors, which testifies to the validity of the pseudostatic experiment and numerical simulation. Parametric results reveal that the influence of developed wall panels made of different strengths of concrete for ameliorating seismic performance of infilled RC frames is very little, whereas the friction factor in the sliding joint is the essential element for enhancing the capacity of infilled RC frames to bear the lateral loadings.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] INELASTIC, CYCLIC BEHAVIOR OF REINFORCED CONCRETE FRAME-WALL STRUCTURES SUBJECTED TO LATERAL FORCES.
    Yamaguchi, Ikuo
    Higashibata, Yasuo
    Sugano, Shunsuke
    Nagashima, Toshio
    Takenaka Technical Research Report, 1980, (24): : 25 - 33
  • [32] Experimental and Numerical Studies on Flexural Behavior of Ultrahigh-Performance Concrete Panels Reinforced with Embedded Glass Fiber-Reinforced Polymer Grids
    Meng, Weina
    Khayat, Kamal H.
    TRANSPORTATION RESEARCH RECORD, 2016, (2592) : 38 - 44
  • [33] Experimental study on steel frame-reinforced concrete infill wall structures with semi-rigid joints
    Peng, Xiaotong
    Gu, Qiang
    Lin, Chen
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2008, 41 (01): : 64 - 69
  • [34] Experimental research on seismic behavior of steel reinforced high strength and high performance concrete frame joints
    Zheng, Shansuo
    Zeng, Lei
    Lu, Ying
    Sun, Qinggang
    Wang, Peiqin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2008, 29 (03): : 128 - 136
  • [35] An experimental and numerical investigation on the cyclic response of a portal frame pier belonging to an old reinforced concrete viaduct
    Paolacci, F.
    Giannini, R.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (06): : 1109 - 1127
  • [36] Lateral behavior of glued-laminated timber frame infilled with light-wooden-frame wall hybrid system: Experimental and numerical analysis
    Xue, Jianyang
    Ren, Guoqi
    Qi, Liangjie
    Zhang, Xin
    STRUCTURES, 2021, 30 : 352 - 367
  • [37] Experimental studies on mechanical behavior of circular tubed reinforced concrete joints with ring ribs
    Gan, Dan
    Zhou, Xuhong
    Yan, Biao
    Han, Fengli
    Liu, Jiepeng
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2018, 39 (04): : 91 - 101
  • [38] Experimental Analysis On Seismic Behavior Of Prefabricated Reinforced Concrete Column To Steel Beam Exterior Joints With Ribbed Angle Steel
    Zhang Z.H.
    Mao G.X.
    Liu Y.
    Xiao A.L.
    Liu Z.L.
    Zhang, Z.H. (zaihua_zhang@163.com), 1600, Eastern Macedonia and Thrace Institute of Technology (14): : 91 - 102
  • [39] Behavior of Fiber Reinforced Key Joints in Precast Concrete Segmental Bridge: Experimental and Numerical Analysis
    Fu, Jundong
    Yuan, Aimin
    Wan, Shui
    JOURNAL OF BRIDGE ENGINEERING, 2021, 26 (08)
  • [40] Experimental and Numerical Investigations on the Seismic Behavior of Lightly Reinforced Concrete Beam-Column Joints
    Li, Bing
    Tran, Cao Thanh Ngoc
    Pan, Tso-Chien
    JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (09) : 1007 - 1018