Experimental Analysis On Seismic Behavior Of Prefabricated Reinforced Concrete Column To Steel Beam Exterior Joints With Ribbed Angle Steel

被引:0
|
作者
Zhang Z.H. [1 ]
Mao G.X. [1 ]
Liu Y. [2 ]
Xiao A.L. [3 ]
Liu Z.L. [4 ]
机构
[1] College of Civil Engineering, Hunan City University, YiYang
[2] Taiyuan University, Taiyuan
[3] Zhongmin Zhuyou Technology Co., Ltd, Changsha
[4] Department of Civil Engineering, University of Auckland, Auckland
来源
Zhang, Z.H. (zaihua_zhang@163.com) | 1600年 / Eastern Macedonia and Thrace Institute of Technology卷 / 14期
关键词
Ductility coefficient; Prefabricated connector with ribbed angle steel; Reinforced concrete-steel beam (RCS) exterior joint; Seismic performance;
D O I
10.25103/jestr.143.11
中图分类号
学科分类号
摘要
Basic structural forms of reinforced concrete column-steel beam composite joints, such as beam-and column-through structures, are difficult to construct due to their complex structure. A joint connection construction method based on the ribbed angle steel was proposed in this study to improve construction performance of such joints, and the industrial assembly construction between reinforced concrete columns and steel beams was realized. By carrying out low cyclic loading test and numerical simulation of three full-scale specimens, the influence of beam–column section,the number of bolts between assembly connectors and steel beams on the performance of joints was examined by carrying out low cyclic loading test and numerical simulation of three full-scale specimens. Moreover, failure mode of joint was analyzed in detail and seismic performance indexes, such as bearing capacity, hysteretic performance, ductility, and energy dissipation capacity of joints, were compared. The results reveal that for different resistance matching among columns, beams, and connectors with ribbed angle steel, there are three failure modes of the joints, namely, shear failure in core area, slip at beam end, and slip at beam end with shear failure in core area. Seismic performance of joints varies with their failure modes. Hysteretic curve of shear failure joint in the core area shows evident pinch phenomenon. Ductility and equivalent viscous damping coefficients are 2.026 and 0.11, respectively. The seismic performance of the joint is consistent with that of the cast-in-place reinforced concrete beam–column joint. The hysteretic curve of the joint is full, ductility, and equivalent viscous damping coefficients reach 3.89 and 0.23, respectively, when slip exists between the connector and the steel beam. The joint demonstrates satisfactory seismic performance. This study provides an experimental basis for the engineering application of the novel prefabricated connection joint. © 2021 School of Science, IHU. All rights reserved.
引用
收藏
页码:91 / 102
页数:11
相关论文
共 50 条
  • [1] Seismic Behavior of Exterior Reinforced Concrete Wide-Column-to-Steel Beam Joints
    Fargier-Gabaldon, Luis B.
    Parra-Montesinos, Gustavo J.
    Wight, James K.
    ACI STRUCTURAL JOURNAL, 2020, 117 (02) : 117 - 128
  • [2] Tests on seismic behavior of exterior joints of prefabricated steel reinforced concrete frame
    Li, Zhong-Xian
    Zhai, Xue-He
    Ding, Yang
    Wu, Chu-Cheng
    Hu, Bei
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2005, 37 (SUPPL. 2): : 319 - 324
  • [3] Seismic behavior of composite interior joints of prefabricated H-shaped steel reinforced concrete column - steel beam
    Wu, Chenglong
    Liu, Jiming
    Tan, Wenya
    Wang, Pengfei
    STRUCTURES, 2020, 23 : 558 - 572
  • [4] Seismic behavior of steel reinforced concrete column-steel truss beam hybrid joints
    Tao, Mu-Xuan
    Fan, Jian-Sheng
    Nie, Jian-Guo
    ENGINEERING STRUCTURES, 2013, 56 : 1557 - 1569
  • [5] Seismic behavior of reinforced concrete column-steel beam joints with and without reinforced concrete slab
    Li, Tong
    Men, Jinjie
    Li, Huan
    Xiong, Liquan
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 86 (03) : 417 - 430
  • [6] Experimental research on seismic behavior of reinforced concrete column-to-steel beam joints with bolted endplate
    Li, Xian
    Xiao, Yan
    Mao, Weifeng
    Zhou, Tao
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2006, 27 (SUPPL.): : 467 - 471
  • [7] Study on seismic behavior of reinforced concrete column-steel beam side joints
    Ling, Yuhong
    Xu, Jinghang
    Guo, Zhenhai
    Wen, Xingui
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2021, 20 (01) : 44 - 60
  • [8] Study on seismic behavior of reinforced concrete column-steel beam side joints
    Ling, Yuhong
    Zheng, Wenli
    Li, Yi
    Zhou, Lianjiang
    Zhou, Jing
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2020, 19 (03) : 187 - 202
  • [9] Experimental study on seismic behavior of angle connection joints for concrete-filled square steel tubular column to steel beam
    Xu M.
    Wu Z.
    Zhang L.
    Liang S.
    Zhang, Lingxin (jzgcsub@163.com), 1600, Science Press (38): : 384 - 393
  • [10] Seismic Behavior of Reinforced Concrete Exterior Wide Beam-Column Joints
    Li, Bing
    Kulkarni, Sudhakar A.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (01): : 26 - 36