A novel method for in vivo measurement of dynamic ischiofemoral space based on MRI and motion

被引:1
|
作者
Wang, Yining [1 ,2 ,3 ,4 ,5 ]
Ma, Dong [1 ,2 ,3 ,4 ,5 ]
Feng, Zhengkuan [1 ,2 ,3 ,4 ,5 ]
Yu, Wanqi [1 ,2 ,3 ,4 ,5 ]
Chen, Yanjun [6 ]
Zhong, Shizhen [1 ,2 ,3 ,4 ,5 ]
Ouyang, Jun [1 ,2 ,3 ,4 ,5 ]
Qian, Lei [1 ,2 ,3 ,4 ,5 ]
机构
[1] Southern Med Univ, Sch Basic Med Sci, Guangdong Prov Key Lab Digital Med & Biomech, Guangzhou, Peoples R China
[2] Southern Med Univ, Sch Basic Med Sci, Guangdong Engn Res Ctr Translat Med 3D Printing Ap, Guangzhou, Peoples R China
[3] Southern Med Univ, Sch Basic Med Sci, Natl Virtual & Real Expt Educ Ctr Med Morphol Sout, Guangzhou, Peoples R China
[4] Southern Med Univ, Sch Basic Med Sci, Natl Expt Educ Demonstrat Ctr Basic Med Sci Southe, Guangzhou, Peoples R China
[5] Southern Med Univ, Sch Basic Med Sci, Natl Key Discipline Human Anat, Guangzhou, Peoples R China
[6] Southern Med Univ, Affiliated Hosp 3, Dept Med Imaging, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
ischiofemoral impingement; in vivo analysis; dynamic bone-to-bone distance; hip model; ischiofemoral space; SOFT-TISSUE ARTIFACT; IMPINGEMENT SYNDROME; MARKER-CLUSTER; KNEE-JOINT; FEMUR; VARIABILITY; IMPACT; WIDTH; GAIT;
D O I
10.3389/fbioe.2023.1067600
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose: To use a novel in vivo method to simulate a moving hip model. Then, measure the dynamic bone-to-bone distance, and analyze the ischiofemoral space (IFS) of patients diagnosed with ischiofemoral impingement syndrome (IFI) during dynamic activities. Methods: Nine healthy subjects and 9 patients with IFI were recruited to collect MRI images and motion capture data. The motion trail of the hip during motion capture was matched to a personalized 3D hip model reconstructed from MRI images to get a dynamic bone model. This personalized dynamic in vivo method was then used to simulate the bone motion in dynamic activities. Validation was conducted on a 3D-printed sphere by comparing the calculated data using this novel method with the actual measured moving data using motion capture. Moreover, the novel method was used to analyze the in vivo dynamic IFS between healthy subjects and IFI patients during normal and long stride walking. Results: The validation results show that the root mean square error (RMSE) of slide and rotation was 1.42 mm/1.84 & DEG; and 1.58 mm/2.19 & DEG;, respectively. During normal walking, the in vivo dynamic IFS was significantly larger in healthy hips (ranged between 15.09 and 50.24 mm) compared with affected hips (between 10.16 and 39.74 mm) in 40.27%-83.81% of the gait cycle (p = 0.027). During long stride walking, the in vivo dynamic IFS was also significantly larger in healthy hips (ranged between 13.02 and 51.99 mm) than affected hips (between 9.63 and 44.22 mm) in 0%-5.85% of the gait cycle (p = 0.049). Additionally, the IFS of normal walking was significantly smaller than long stride walking during 0%-14.05% and 85.07%-100% of the gait cycle (p = 0.033, 0.033) in healthy hips. However, there was no difference between the two methods of walking among the patients. Conclusions: This study established a novel in vivo method to measure the dynamic bone-to-bone distance and was well validated. This method was used to measure the IFS of patients diagnosed with IFI, and the results showed that the IFS of patients is smaller compared with healthy subjects, whether in normal or long stride walking. Meanwhile, IFI eliminated the difference between normal and long stride walking.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A Novel MRI Tracer-Based Method for Measuring Water Diffusion in the Extracellular Space of the Rat Brain
    Han, Hongbin
    Shi, Chunyan
    Fu, Yu
    Zuo, Long
    Lee, Kejia
    He, Qingyuan
    Han, Haojun
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (03) : 978 - 983
  • [32] A novel method for on-orbit measurement of space materials degradation
    Verker, Ronen
    Grossman, Eitan
    Gouzman, Irina
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02):
  • [33] A novel method for deriving reservoir operation curves based on the concept of dynamic variable sampling space
    Wang, X.
    Guo, X. N.
    Chen, X.
    Lei, X. H.
    Jiang, Y. Z.
    Wang, H.
    Manufacturing and Engineering Technology, 2015, : 249 - 254
  • [35] A novel vibration system based on instantaneous motion centre for high accuracy dynamic balancing measurement of outboard rotor
    Peng, Q.
    Ping, C.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2009, 223 (02) : 387 - 395
  • [36] A novel relative motion measurement method based on distributed POS relative parameters matching transfer alignment
    Qu, Chunyu
    Li, Jianli
    MEASUREMENT, 2022, 202
  • [37] A GUI based Automatic Tester with A Novel Heating Method for Power Semiconductor Device Dynamic Measurement
    Ma, Qingxuan
    Zhang, Liqi
    Huang, Alex Q.
    Lee, Meng-Chia
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 3597 - 3601
  • [38] Novel QUEST MRI In Vivo Measurement of Noise-induced Oxidative Stress in the Cochlea
    Kuhl, Andre
    Dixon, Angela
    Hali, Mirabela
    Apawu, Aaron K.
    Muca, Antonela
    Sinan, Moaz
    Warila, James
    Braun, Rod D.
    Berkowitz, Bruce A.
    Holt, Avril Genene
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [39] Novel QUEST MRI In Vivo Measurement of Noise-induced Oxidative Stress in the Cochlea
    André Kühl
    Angela Dixon
    Mirabela Hali
    Aaron K. Apawu
    Antonela Muca
    Moaz Sinan
    James Warila
    Rod D. Braun
    Bruce A. Berkowitz
    Avril Genene Holt
    Scientific Reports, 9
  • [40] A novel demosaicing method based on the YCbCr space
    Cheng, Feng-Chi
    Tsai, Chung-Chin
    Hsu, Shun-Pin
    Chang, Yuh-Chin
    PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 1198 - +