A novel method for in vivo measurement of dynamic ischiofemoral space based on MRI and motion

被引:1
|
作者
Wang, Yining [1 ,2 ,3 ,4 ,5 ]
Ma, Dong [1 ,2 ,3 ,4 ,5 ]
Feng, Zhengkuan [1 ,2 ,3 ,4 ,5 ]
Yu, Wanqi [1 ,2 ,3 ,4 ,5 ]
Chen, Yanjun [6 ]
Zhong, Shizhen [1 ,2 ,3 ,4 ,5 ]
Ouyang, Jun [1 ,2 ,3 ,4 ,5 ]
Qian, Lei [1 ,2 ,3 ,4 ,5 ]
机构
[1] Southern Med Univ, Sch Basic Med Sci, Guangdong Prov Key Lab Digital Med & Biomech, Guangzhou, Peoples R China
[2] Southern Med Univ, Sch Basic Med Sci, Guangdong Engn Res Ctr Translat Med 3D Printing Ap, Guangzhou, Peoples R China
[3] Southern Med Univ, Sch Basic Med Sci, Natl Virtual & Real Expt Educ Ctr Med Morphol Sout, Guangzhou, Peoples R China
[4] Southern Med Univ, Sch Basic Med Sci, Natl Expt Educ Demonstrat Ctr Basic Med Sci Southe, Guangzhou, Peoples R China
[5] Southern Med Univ, Sch Basic Med Sci, Natl Key Discipline Human Anat, Guangzhou, Peoples R China
[6] Southern Med Univ, Affiliated Hosp 3, Dept Med Imaging, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
ischiofemoral impingement; in vivo analysis; dynamic bone-to-bone distance; hip model; ischiofemoral space; SOFT-TISSUE ARTIFACT; IMPINGEMENT SYNDROME; MARKER-CLUSTER; KNEE-JOINT; FEMUR; VARIABILITY; IMPACT; WIDTH; GAIT;
D O I
10.3389/fbioe.2023.1067600
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose: To use a novel in vivo method to simulate a moving hip model. Then, measure the dynamic bone-to-bone distance, and analyze the ischiofemoral space (IFS) of patients diagnosed with ischiofemoral impingement syndrome (IFI) during dynamic activities. Methods: Nine healthy subjects and 9 patients with IFI were recruited to collect MRI images and motion capture data. The motion trail of the hip during motion capture was matched to a personalized 3D hip model reconstructed from MRI images to get a dynamic bone model. This personalized dynamic in vivo method was then used to simulate the bone motion in dynamic activities. Validation was conducted on a 3D-printed sphere by comparing the calculated data using this novel method with the actual measured moving data using motion capture. Moreover, the novel method was used to analyze the in vivo dynamic IFS between healthy subjects and IFI patients during normal and long stride walking. Results: The validation results show that the root mean square error (RMSE) of slide and rotation was 1.42 mm/1.84 & DEG; and 1.58 mm/2.19 & DEG;, respectively. During normal walking, the in vivo dynamic IFS was significantly larger in healthy hips (ranged between 15.09 and 50.24 mm) compared with affected hips (between 10.16 and 39.74 mm) in 40.27%-83.81% of the gait cycle (p = 0.027). During long stride walking, the in vivo dynamic IFS was also significantly larger in healthy hips (ranged between 13.02 and 51.99 mm) than affected hips (between 9.63 and 44.22 mm) in 0%-5.85% of the gait cycle (p = 0.049). Additionally, the IFS of normal walking was significantly smaller than long stride walking during 0%-14.05% and 85.07%-100% of the gait cycle (p = 0.033, 0.033) in healthy hips. However, there was no difference between the two methods of walking among the patients. Conclusions: This study established a novel in vivo method to measure the dynamic bone-to-bone distance and was well validated. This method was used to measure the IFS of patients diagnosed with IFI, and the results showed that the IFS of patients is smaller compared with healthy subjects, whether in normal or long stride walking. Meanwhile, IFI eliminated the difference between normal and long stride walking.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A novel method of fast dynamic optical image stabilization precision measurement based on CCD
    Li, Jing
    Wang, Junzheng
    Wang, Shoukun
    OPTIK, 2011, 122 (07): : 582 - 585
  • [22] In vivo patellofemoral contact mechanics during active extension using a novel dynamic MRI-based methodology
    Borotikar, B. S.
    Sheehan, F. T.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (12) : 1886 - 1894
  • [23] Novel Introduction of In Vivo Dynamic Nuclear Polarized MRI for the Visual Verification of IMRT
    Mori, T.
    Hyodo, F.
    Mori, T.
    Koyasu, N.
    Kobori, A.
    Takano, H.
    Makita, C.
    Matsuo, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : S210 - S210
  • [24] Subtle In-Scanner Motion Biases Automated Measurement of Brain Anatomy From In Vivo MRI
    Alexander-Bloch, Aaron
    Clasen, Liv
    Stockman, Michael
    Ronan, Lisa
    Lalonde, Francois
    Giedd, Jay
    Raznahan, Armin
    HUMAN BRAIN MAPPING, 2016, 37 (07) : 2385 - 2397
  • [25] Dynamic method for magnetic torque measurement using pendulum motion system
    Lin, Chin E.
    Jou, H.L.
    Yan, J.H.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1994, 1 : 376 - 379
  • [26] A Novel Retrieval Method based on Semantic Motion
    Xiang, Jian
    AUTOMATION EQUIPMENT AND SYSTEMS, PTS 1-4, 2012, 468-471 : 103 - 106
  • [27] In vivo validation of a novel method for regional myocardial wall motion analysis based on echocardiographic tissue tracking
    Dan Rappaport
    Eugene Konyukhov
    Dan Adam
    Amir Landesberg
    Peter Lysyansky
    Medical & Biological Engineering & Computing, 2008, 46 : 131 - 137
  • [28] In vivo validation of a novel method for regional myocardial wall motion analysis based on echocardiographic tissue tracking
    Rappaport, Dan
    Konyukhov, Eugene
    Adam, Dan
    Landesberg, Amir
    Lysyansky, Peter
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (02) : 131 - 137
  • [29] A correlation-based motion correction method for functional MRI
    Calderon, A
    Kanayama, S
    Kuhara, S
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 1998, E81D (06) : 602 - 608
  • [30] Quantitative Analysis of Peristaltic and Segmental Motion In Vivo in the Rat Small Intestine Using Dynamic MRI
    Ailiani, Amit C.
    Neuberger, Thomas
    Brasseur, James G.
    Banco, Gino
    Wang, Yanxing
    Smith, Nadine B.
    Webb, Andrew G.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 116 - 126