Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review

被引:8
|
作者
Chen, Jiaxin [1 ]
Zhao, Shuhua [1 ]
Zhu, Qianqian [1 ]
机构
[1] Sun Yat Sen Univ, Dept Anesthesiol, Affiliated Hosp 7, 628 Zhenyuan Rd, Shenzhen 518107, Guangdong, Peoples R China
关键词
SVV; PPV; Laparoscopic surgery; POSTOPERATIVE PULMONARY COMPLICATIONS; MECHANICALLY VENTILATED PATIENTS; CONTOUR METHODS IMPACT; GOAL-DIRECTED THERAPY; PNEUMOPERITONEUM; VARIABLES; METAANALYSIS; MANAGEMENT;
D O I
10.1007/s10877-022-00939-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The reliability of stroke volume variation (SVV) and pulse pressure variation (PPV) in predicting fluid responsiveness during laparoscopic surgery remains unclear. We conducted the present systematic review to summarize the current evidence. We reviewed studies that investigated the reliability of SVV and PPV in laparoscopic surgery. Seven studies were included in the final analysis. Two studies demonstrated that the area under the receiver operating characteristic curve (AUROC) for SVV was less than 0.8, and five studies reported that the AUROC was > 0.8. The pooled AUROC for SVV and PPV was more than 0.8 with high heterogeneities between the included studies. Most individual studies have suggested that SVV and PPV are sufficiently reliable for predicting fluid responsiveness during laparoscopic surgery. However, the limited number of patients, varied apparatus used to define fluid responsiveness, diverse definitions of fluid responsiveness, and different fluids used to perform fluid challenges in the included studies render firm conclusions about SVV's and PPV's reliability impossible.
引用
收藏
页码:379 / 387
页数:9
相关论文
共 50 条
  • [21] Noninvasive pulse pressure variation and stroke volume variation to predict fluid responsiveness at multiple thresholds: a prospective observational study
    Vos, Jaap Jan
    Poterman, Marieke
    Salm, Pieternel Papineau
    Van Amsterdam, Kai
    Struys, Michel M. R. F.
    Scheeren, Thomas W. L.
    Kalmar, Alain F.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (11): : 1153 - 1160
  • [22] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [23] Reliability of Passive Leg Raising, Stroke Volume Variation and Pulse Pressure Variation to Predict Fluid Responsiveness During Weaning From Mechanical Ventilation After Cardiac Surgery: A Prospective, Observational Study
    Hofer, Christoph Karl
    Geisen, Martin
    Hartnack, Sonja
    Dzemali, Omer
    Ganter, Michael Thomas
    Zollinger, Andreas
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2018, 46 (02) : 108 - 115
  • [24] Comparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients
    Hong, Jin-Quan
    He, He-Fan
    Chen, Zhi-Yuan
    Du, Zhen-Shuang
    Liu, Wei-Feng
    Weng, Pei-Qing
    Huang, Hao-Bo
    SAUDI MEDICAL JOURNAL, 2014, 35 (03) : 261 - 268
  • [25] Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation
    Khwannimit, Bodin
    Bhurayanontachai, Rungsun
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (02) : 64 - 69
  • [26] Stroke volume variation compared with pulse pressure variation and cardiac index changes for prediction of fluid responsiveness in mechanically ventilated patients
    Soliman, Randa Aly
    Samir, Shereif
    el Naggar, Ayman
    El Dehely, Khalaf
    EGYPTIAN JOURNAL OF CRITICAL CARE MEDICINE, 2015, 3 (01): : 9 - 16
  • [27] Does stroke volume variation predict fluid responsiveness in children: A systematic review and meta-analysis
    Yi, Ling
    Liu, Zhongqiang
    Qiao, Lina
    Wan, Chaomin
    Mu, Dezhi
    PLOS ONE, 2017, 12 (05):
  • [28] Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
    Alvarado Sanchez, Jorge Ivan
    Caicedo Ruiz, Juan Daniel
    Diaztagle Fernandez, Juan Jose
    Adolfo Ospina-Tascon, Gustavo
    Cruz Martinez, Luis Eduardo
    CLINICAL MEDICINE INSIGHTS-CIRCULATORY RESPIRATORY AND PULMONARY MEDICINE, 2020, 14
  • [29] Stroke Volume Variation for Prediction of Fluid Responsiveness in Patients Undergoing Gastrointestinal Surgery
    Li, Cheng
    Lin, Fu-qing
    Fu, Shu-kun
    Chen, Guo-qiang
    Yang, Xiao-hu
    Zhu, Chun-yan
    Zhang, Li-jun
    Li, Quan
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2013, 10 (02): : 148 - 155
  • [30] Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    Berkenstadt, H
    Margalit, N
    Hadani, M
    Friedman, Z
    Segal, E
    Villa, Y
    Perel, A
    ANESTHESIA AND ANALGESIA, 2001, 92 (04): : 984 - 989