Electroless Deposition of Gold on a Glassy Carbon Electrode (GCE) Surface for Selective Detection of Hydrogen Peroxide

被引:2
|
作者
Imran Hossain, Mohammad [1 ]
Dutta, Anim [1 ]
Ahmed, Jahir [2 ,3 ]
Faisal, Mohd [2 ,3 ]
Algethami, Jari S. [2 ,3 ]
Harraz, Farid A. [2 ,4 ]
Hasnat, Mohammad A. [1 ]
机构
[1] Shahjalal Univ Sci & Technol, Sch Phys Sci, Dept Chem, Electrochem & Catalysis Res Lab ECRL, Sylhet 3114, Bangladesh
[2] Najran Univ, Promising Ctr Sensors & Elect Devices PCSED, Adv Mat & Nanores Ctr, Najran 11001, Saudi Arabia
[3] Najran Univ, Fac Sci & Arts, Dept Chem, Najran 11001, Saudi Arabia
[4] Najran Univ, Fac Sci & Arts Sharurah, Dept Chem, Sharurah 68342, Saudi Arabia
来源
CHEMISTRYSELECT | 2024年 / 9卷 / 01期
关键词
Chemisorption; Electroless deposition; Glassy carbon electrode; Hydrogen peroxide sensor; Kinetics; COLLOIDAL GOLD; ELECTROCHEMICAL DETECTION; AMPEROMETRIC SENSOR; NANOPARTICLES; GRAPHENE; REDUCTION; IMMOBILIZATION; SUBMONOLAYER; HYDROQUINONE; DEGRADATION;
D O I
10.1002/slct.202301638
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electroless deposition technique was employed to coat the surface of a glassy carbon electrode (GCE) with nanoparticles of gold (AuNPs). Afterward, sulfur (S) components were immobilized onto this AuNPs/GC electrode via an in-situ chemisorption approach that considerably enhanced the catalytic activity, conductivity, and persistent durability of the electrode. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS) were used to characterize the modified electrode surface. The experimental results indicated that the S-AuNPs/GC electrode exhibits outstanding catalytic activity for the selective detection of H2O2 (HP). SWV measurements showed that the electrochemical sensor has a wide linear range of 10 to 2500 mu M and a heightened sensitivity of 50.08 mu A mM-1 cm-2. The proposed HP sensor demonstrated adequate repeatability and durability, as well as interference-free quantitative analysis capability. Conventional GCE and Au electrodes are ineffective in carrying out hydrogen peroxide (HP) reduction reactions. Whereas Au NPs modified GCE break down HP to O2 causing O2 interference in the subsequent HP sensing. In such a case, a sulfur adlayer can seal the Au facets responsible for O2 reduction allowing the unblocking of the active sites of Au at -0.93 V enabling a two-electron transfer HP reduction reaction.image
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Electroless deposition of Gold-Platinum Core@Shell Nanoparticles on Glassy Carbon Electrode for Non-Enzymatic Hydrogen Peroxide sensing
    Gowthaman, N. S. K.
    John, S. Abraham
    JOURNAL OF CHEMICAL SCIENCES, 2016, 128 (03) : 331 - 338
  • [2] Electroless deposition of Gold-Platinum Core@Shell Nanoparticles on Glassy Carbon Electrode for Non-Enzymatic Hydrogen Peroxide sensing#
    N S K GOWTHAMAN
    S ABRAHAM JOHN
    Journal of Chemical Sciences, 2016, 128 : 331 - 338
  • [3] Electrochemical Determination of Hydrogen Peroxide Using a Horseradish Peroxidase (HRP) Modified Gold-Nickel Alloy Nanoparticles Glassy Carbon Electrode (GCE)
    Sun, Mengmeng
    Shen, Guodong
    Bai, Zhengchen
    Zhang, Hongqing
    Liu, Haiyan
    Liang, Xinyi
    ANALYTICAL LETTERS, 2021, 54 (16) : 2565 - 2573
  • [4] A modified glassy carbon electrode for hydrogen peroxide sensing
    Zheng, Cai-yun
    Chen, Shui-hong
    Shang, Yong-jia
    Li, Mao-guo
    ANNALI DI CHIMICA, 2007, 97 (11-12) : 1227 - 1235
  • [5] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Qingxia Wang
    Haili Zhang
    Yiwei Wu
    Aimin Yu
    Microchimica Acta, 2012, 176 : 279 - 285
  • [6] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [7] AN ENZYME ELECTRODE FOR HYDROGEN-PEROXIDE DETECTION BASED ON PEROXIDASE IMMOBILIZED ON A GLASSY-CARBON ELECTRODE
    NARASAIAH, D
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (06): : 415 - 422
  • [9] Selective detection of neurotransmitter serotonin by a gold nanoparticle-modified glassy carbon electrode
    Wei, Xiaohan
    Wang, Fei
    Yin, Yumin
    Liu, Qiongyan
    Zou, Lina
    Ye, Baoxian
    ANALYST, 2010, 135 (09) : 2286 - 2290
  • [10] Electroless Deposition of Silver Nanoparticles on Graphene Oxide Surface and Its Applications for the Detection of Hydrogen Peroxide
    Zhu, Jun
    Kim, KeunSoo
    Liu, Zhenxian
    Feng, Huan
    Hou, Shifeng
    ELECTROANALYSIS, 2014, 26 (11) : 2513 - 2519