TCV Tokamak Neutron Shielding Upgrade for Dual NBI Operation

被引:5
|
作者
Weisen, H. [1 ]
Blanchard, P. [1 ]
Vallar, M. [1 ]
Karpushov, A. N. [1 ]
Dubray, J. [1 ]
Merle, A. [1 ]
Duval, B. P. [1 ]
Cazabonne, J. [1 ]
Testa, D. [1 ]
Elaian, H. Hamac [1 ]
Zohar, A. [2 ]
Snoj, L. [2 ]
Kos, B. [2 ,5 ]
Fortuna, M.
Cufar, A. [2 ]
Tesse, F. [3 ]
Fontana, F. [3 ]
Gloor, C. [3 ]
Iannarelli, R. [3 ]
Palacios, H. [3 ]
Tille, C. [3 ]
Molteni, M. [4 ]
机构
[1] Ecole Polytech Fed Lausanne EPFL, Swiss Plasma Ctr SPC, CH-1015 Lausanne, Switzerland
[2] Jozef Stefan Inst, Jamova Cesta 39, Ljubljana 1000, Slovenia
[3] Ecole Polytech Fed Lausanne EPFL, Dev & Construct VPO DC, CH-1015 Lausanne, Switzerland
[4] Willy Ingenieurs, Av 14 Avril 20, CH-1020 Renens, Switzerland
[5] Oak Ridge Natl Lab, Oak Ridge, TN 37830 USA
关键词
Radiation protection; neutron dose; tokamak; safety;
D O I
10.1080/15361055.2023.2209490
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Tokamak a Configuration variable (TCV) is equipped with two neutral beam injection (NBI) systems delivering up to 1.2 MW each for pulse durations of up to 2 s. The first system (NBI1), designed for an injection energy in the range of 25 to 30 keV has been operational since 2016. The existing concrete neutron shielding of the experimental hall proved insufficient for fully protecting human accessible areas, limiting the number of daily plasma pulses using NBI1. The recently commissioned second system (NBI2) is designed for injection synergies in the range 50 to 60 keV. Both systems are tangentially oriented in opposite directions in order to permit experiments with low or no net torque. Calculations with the TRANSP and ORBIS heating codes show that neutron rates from deuterium-deuterium fusion reactions may be as high as 10(14) n/s, up to 10 times higher than with the lower energy beam only. This is due both to the similar to five times larger beam-plasma neutron rates from the higher energy beam and to an exceptionally high contribution from beam-beam reactions between the opposing beams. The radiation protection policy at the Swiss Plasma Center is that all staff members be considered as members of the general public, limiting the daily personal dose to 4 mu Sv. This is also the maximum admissible daily dose in any publicly accessible zone, whether occupied or not. Currently, with only the lower energy beam, this limit can be attained in the control room adjacent to the device hall after only five NBI pulses out of a possible 30 daily pulses. To allow for exploitation of the two beams at full specifications, the source side of the existing barite concrete walls of the 15 x 20 x 8 m large TCV hall will be covered with 20-cm-thick polythene (PE) cladding and a ceiling made of 35-cm-thick PE will be added. The total mass of PE will be 200 tons. The usage of PE at this scale for neutron shielding is unprecedented at any fusion research facility.
引用
收藏
页码:143 / 155
页数:13
相关论文
共 50 条
  • [31] Recent advancements with the H- injector performance for the Spallation Neutron Source operation and upgrade
    Han, Baoxi
    Welton, Robert
    Stinson, Chris
    Andzulis, Vic
    Terszakowec, Greg
    Piller, Chip
    Narayan, Amith
    Peplov, Vladimir
    Pennisi, Terry
    Murray, Syd, Jr.
    Stockli, Martin
    Kim, Sang-Ho
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [32] Steady-state fully noninductive operation with electron cyclotron current drive and current profile control in the tokamak a configuration variable (TCV)
    Sauter, O
    Angioni, C
    Coda, S
    Gomez, P
    Goodman, TP
    Henderson, MA
    Hofmann, F
    Hogge, JP
    Moret, JM
    Nikkola, P
    Pietrzyk, ZA
    Weisen, H
    Alberti, S
    Appert, K
    Bakos, J
    Behn, R
    Blanchard, P
    Bosshard, P
    Chavan, R
    Condrea, I
    Degeling, A
    Duval, BP
    Fasel, D
    Favez, JY
    Favre, A
    Furno, I
    Kayruthdinov, RR
    Lavanchy, P
    Lister, JB
    Llobet, X
    Lukash, VE
    Gorgerat, P
    Isoz, PF
    Joye, B
    Magnin, JC
    Manini, A
    Marlétaz, B
    Marmillod, P
    Martin, YR
    Martynov, A
    Mayor, JM
    Minardi, E
    Mlynar, J
    Paris, PJ
    Perez, A
    Peysson, Y
    Piffl, V
    Pitts, RA
    Pochelon, A
    Reimerdes, H
    PHYSICS OF PLASMAS, 2001, 8 (05) : 2199 - 2207
  • [33] Fission chamber data acquisition system for neutron flux measurements on the Mega-Amp Spherical Tokamak Upgrade
    Vincent, C.
    Allan, S.
    Naylor, G.
    Stephen, R.
    Bray, S.
    Thornton, A.
    Kirk, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (09):
  • [34] Stationarity of I-mode operation and I-mode divertor heat fluxes on the ASDEX Upgrade tokamak
    Happel, T.
    Griener, M.
    Silvagni, D.
    Freethy, S. J.
    Hennequin, P.
    Janky, F.
    Manz, P.
    Prisiazhniuk, D.
    Ryter, F.
    Bernert, M.
    Brida, D.
    Eich, T.
    Faitsch, M.
    Gil, L.
    Guimarais, L.
    Merle, A.
    Nille, D.
    Pinzon, J.
    Sieglin, B.
    Stroth, U.
    Viezzer, E.
    NUCLEAR MATERIALS AND ENERGY, 2019, 18 : 159 - 165
  • [35] Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak
    Du, T. F.
    Chen, Z. J.
    Peng, X. Y.
    Yuan, X.
    Zhang, X.
    Gorini, G.
    Nocente, M.
    Tardocchi, M.
    Hu, Z. M.
    Cui, Z. Q.
    Xie, X. F.
    Ge, L. J.
    Hu, L. Q.
    Zhong, G. Q.
    Lin, S. Y.
    Wan, B. N.
    Li, X. Q.
    Zhang, G. H.
    Chen, J. X.
    Fan, T. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [36] CALIBRATION OF THE NEUTRON-ACTIVATION SYSTEM ON THE FRASCATI TOKAMAK UPGRADE - COMPARISON BETWEEN MEASURED AND CALCULATED ACTIVATION RESPONSE COEFFICIENTS
    ANGELONE, M
    BATISTONI, P
    MARTONE, M
    PILLON, M
    RAPISARDA, M
    ROLLET, S
    FUSION TECHNOLOGY, 1991, 19 (03): : 431 - 439
  • [37] Design of a magnetic shielding system for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak
    Cui, Z. Q.
    Chen, Z. J.
    Xie, X. F.
    Peng, X. Y.
    Hu, Z. M.
    Du, T. F.
    Ge, L. J.
    Zhang, X.
    Yuan, X.
    Xia, Z. W.
    Hu, L. Q.
    Zhong, G. Q.
    Lin, S. Y.
    Wan, B. N.
    Fan, T. S.
    Chen, J. X.
    Li, X. Q.
    Zhang, G. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [38] Electrical integration of two 1MW/2s dual-frequency gyrotrons into the EC-system of the TCV tokamak
    Siravo, U.
    Alberti, S.
    Dubray, J.
    Fasel, D.
    Perez, A.
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 1510 - 1514
  • [39] ELM pacing and high-density operation using pellet injection in the ASDEX Upgrade all-metal-wall tokamak
    Lang, P. T.
    Burckhart, A.
    Bernert, M.
    Casali, L.
    Fischer, R.
    Kardaun, O.
    Kocsis, G.
    Maraschek, M.
    Mlynek, A.
    Ploeckl, B.
    Reich, M.
    Ryter, F.
    Schweinzer, J.
    Sieglin, B.
    Suttrop, W.
    Szepesi, T.
    Tardini, G.
    Wolfrum, E.
    Zasche, D.
    Zohm, H.
    NUCLEAR FUSION, 2014, 54 (08)
  • [40] Power Supply Circuit for Dual Operation in Producing Tokamak and Reversed Field Pinch Plasmas in RELAX
    Inoue, Takeru
    Inagaki, Shinichiro
    Sanpei, Akio
    Himura, Haruhiko
    PLASMA AND FUSION RESEARCH, 2024, 19