CALIBRATION OF THE NEUTRON-ACTIVATION SYSTEM ON THE FRASCATI TOKAMAK UPGRADE - COMPARISON BETWEEN MEASURED AND CALCULATED ACTIVATION RESPONSE COEFFICIENTS

被引:6
|
作者
ANGELONE, M
BATISTONI, P
MARTONE, M
PILLON, M
RAPISARDA, M
ROLLET, S
机构
来源
FUSION TECHNOLOGY | 1991年 / 19卷 / 03期
关键词
TOKAMAK; NEUTRON YIELD; ACTIVATION MEASUREMENTS;
D O I
10.13182/FST91-A29383
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Frascati Tokamak Upgrade (FTU) neutron activation system has been calibrated using indium foils and a 252Cf spontaneous fission neutron source located at several positions within the tokamak. The same experimental arrangements have been simulated with the MCNP Monte Carlo neutron and photon transport code in order to numerically reproduce the activation response coefficients measured experimentally. The main purpose of the comparison is to assess the accuracy of the numerical simulation and of the modeling of the FTU device. This analysis has a more general relevance in view of the use of the activation system as an independent method for the absolute measurement of the neutron yield in next-step fusion devices. An overall agreement at the 22% level between experiment and calculation has been demonstrated.
引用
收藏
页码:431 / 439
页数:9
相关论文
共 14 条
  • [1] EXPERIMENTAL AND NUMERICAL CALIBRATION OF THE NEUTRON-ACTIVATION SYSTEM ON THE FTU TOKAMAK
    ANGELONE, M
    BATISTONI, P
    BERTALOT, L
    ESPOSITO, B
    MARTONE, M
    PILLON, M
    PODDA, S
    RAPISARDA, M
    ROLLET, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 3157 - 3159
  • [2] HPGe well-type detectors for neutron activation measurements on the Frascati Tokamak Upgrade tokamak
    Bertalot, L
    Damiani, M
    Esposito, B
    Lagamba, L
    Podda, S
    Batistoni, P
    DeFelice, P
    Biagini, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 528 - 531
  • [3] CALIBRATION OF THE TFTR NEUTRON-ACTIVATION SYSTEM
    NIESCHMIDT, EB
    SAITO, T
    BARNES, CW
    BOSCH, HS
    MURPHY, TJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1715 - 1717
  • [4] CALCULATED GAMMA-RAY AND OR NEUTRON ATTENUATION COEFFICIENTS IN 14 MEV NEUTRON-ACTIVATION ANALYSIS
    ELAYI, AG
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1983, 76 (01): : 203 - 213
  • [5] COMPARISON OF THE SELENIUM CONTENTS OF VEGETABLES OF THE GENUS ALLIUM MEASURED BY FLUOROMETRY AND NEUTRON-ACTIVATION ANALYSIS
    NODA, K
    TANIGUCHI, H
    SUZUKI, S
    HIRAI, S
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1983, 47 (03): : 613 - 615
  • [6] COMPARISON BETWEEN CONCENTRATION PROFILES OF ARSENIC IMPLANTED IN SILICON MEASURED BY MEANS OF NEUTRON-ACTIVATION ANALYSIS AND RADIOACTIVE ION-IMPLANTATION
    IWAKI, M
    GAMO, K
    MASUDA, K
    NAMBA, S
    ISHIHARA, S
    KIMURA, I
    YOKOTA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1975, 14 (01) : 167 - 168
  • [7] A COMPARISON OF CHANGES IN BODY NITROGEN MEASURED BY INVIVO NEUTRON-ACTIVATION ANALYSIS AND URINARY NITROGEN-BALANCE
    KING, RFGJ
    MCMAHON, MJ
    BURKINSHAW, L
    LAUGHLAND, A
    ALMOND, DJ
    YEUNG, CK
    SMITH, RC
    CLINICAL NUTRITION, 1988, 7 (04) : 231 - 236
  • [8] NEUTRON-ACTIVATION STUDIES OF CORRELATION BETWEEN ENRICHMENT FACTOR AND RESIDENCE TIME IN MARINE SYSTEM
    CHAI, ZF
    MAO, XY
    MA, SL
    KEXUE TONGBAO, 1986, 31 (01): : 53 - 56
  • [9] COMPARISON OF ELEMENTAL COMPOSITION OF HAIR BETWEEN OSTEOPOROTIC AND NORMAL WOMEN BY INSTRUMENTAL NEUTRON-ACTIVATION ANALYSIS
    STEPHENSNEWSHAM, LG
    DUKE, MJM
    OVERTON, TR
    NG, D
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 113 (02): : 495 - 500
  • [10] DESTRUCTIVE NEUTRON-ACTIVATION ANALYSIS OF RARE-EARTHS IN GEOLOGICAL SAMPLES - A COMPARISON BETWEEN 2 METHODS
    MELONI, S
    ODDONE, M
    CECCHI, A
    POLI, G
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1982, 71 (1-2): : 429 - 446