BackgroundLeaks from incomplete ligation of the left atrial appendage (LAA) following closure with Lariat device are not uncommon and associated with higher stroke rate. Clinical VignetteThis clinical vignette highlights a procedure of closure of residual leak following closure with Lariat device. There was a persistent central leak of 3-4 mm with bidirectional flow, confirmed on TEE. The Amplatzer Talisman PFO Occluder was chosen for the closure of the leak because of its asymmetric discs with a smaller distal disc and expandable waist. ConclusionIn situations where the options are limited for PDL closure, such as the one described in this vignette, it is paramount to continue to find innovative solutions to emerging challenges in transcatheter interventions.
机构:
Mayo Clin, Dept Cardiol, Sch Med, Rochester, MN 55905 USA
Mayo Clin, 200 First St SW, Rochester, MN 55905 USAMayo Clin, Dept Cardiol, Sch Med, Rochester, MN 55905 USA