Biomechanical comparison of four triangular osteosynthesis fixations for unilateral vertical sacral fractures

被引:5
|
作者
Ma, Yupeng [1 ,2 ]
Zhao, Yong [1 ,2 ]
Hong, Huanyu [1 ]
Huang, Tao [1 ]
Li, Yu [1 ]
机构
[1] Yantai Shan Hosp, Orthopaed Dept, 91 Jiefang Rd, Yantai 264008, Shandong, Peoples R China
[2] Yantai Shan Hosp, Yantai Key Lab Repair & Reconstruct Bone & Joint, Yantai, Peoples R China
基金
中国国家自然科学基金;
关键词
PERCUTANEOUS ILIOSACRAL SCREWS; SURGICAL DECOMPRESSION; SACROILIAC SCREWS; STABILITY; INJURIES; KINDS;
D O I
10.1038/s41598-023-31418-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To compare the stability and biomechanical characteristics of four commonly used triangular osteosynthesis techniques to treat unilateral vertical sacral fractures and provide a clinical application reference. Finite element models of Tile C-type pelvic ring injury (unilateral Denis II sacral fracture) were produced. In four models, sacral fractures were fixed with a combination of unilateral L5, unilateral L4, and L5 iliac lumbar fixation with lengthened or normal sacroiliac screws. The biomechanical properties of the four fixation models were measured and compared under bipedal stance and lumbar rotation. The fixation stability of the model with the lengthened sacroiliac screw was excellent, and the fracture end was stable. The stability of fixation using unilateral L4 and L5 segments was close to that of unilateral L5 segment fixation. Triangular osteosynthesis transverse stabilization devices using lengthened sacroiliac screws can increase the vertical stability of the sacrum after internal fixation and increase the stability of the fracture. When triangular osteosynthesis lumbar fixation segments were selected, simultaneous fixation of L4 and L5 segments versus only L5 segments did not significantly enhance the vertical stability of the sacrum or the stability of the fracture end.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
    Ming Ni
    Duo Wai-Chi Wong
    Jiong Mei
    Wenxin Niu
    Ming Zhang
    Science China Life Sciences, 2016, 59 : 958 - 964
  • [42] Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
    Ni, Ming
    Wong, Duo Wai-Chi
    Mei, Jiong
    Niu, Wenxin
    Zhang, Ming
    SCIENCE CHINA-LIFE SCIENCES, 2016, 59 (09) : 958 - 964
  • [43] A Comprehensive Analysis With Minimum 1-Year Follow-up of Vertically Unstable Transforaminal Sacral Fractures Treated With Triangular Osteosynthesis Commentary
    Schildhauer, Thomas A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (05) : 319 - 321
  • [44] Triangular Osteosynthesis Using an S1 Pedicle Screw and S2 Alar Iliac Screw for a Unilateral Vertically Displaced Sacral Fracture
    Lee, Han-Dong
    Jeon, Chang-Hoon
    Chung, Nam-Su
    Jeong, Seungmin
    Song, Hyung-Keun
    WORLD NEUROSURGERY, 2020, 142 : 57 - 61
  • [45] Comparison of Transverse Cancellous Lag Screw and Ordinary Cannulated Screw Fixations in Treatment of Vertical Femoral Neck Fractures
    Dong, Qiang
    Han, Zhe
    Zhang, Yin-Guang
    Sun, Xiang
    Ma, Xin-Long
    ORTHOPAEDIC SURGERY, 2019, 11 (04) : 595 - 603
  • [46] Biomechanical comparison of a multidirectional locking plate and conventional plates for the osteosynthesis of mandibular angle fractures-A preliminary study
    Zimmermann, Catarina
    Henningsen, Anders
    Henkel, Kai-Olaf
    Klatt, Jan
    Juergens, Christian
    Seide, Klaus
    Kienast, Benjamin
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (12) : 1913 - 1920
  • [47] Biomechanical comparison of four different fixation techniques for pediatric tibial eminence avulsion fractures
    Mahar, Andrew T.
    Duncan, Doug
    Oka, Richard
    Lowry, Alexandra
    Gillingham, Bruce
    Chambers, Henry
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2008, 28 (02) : 159 - 162
  • [48] Ex Vivo Biomechanical Comparison of Four Techniques to Tibiotarsus Osteosynthesis in Adult Laying Hens (Gallus gallus domesticus)
    de Carvalho, Anderson Luiz
    Formenton, Ana Barbara Krummenauer
    Campos, Joanna Kulczynski
    Fraga Junior, Vilson Ferreira
    Monteiro, Eduardo Raposo
    Vassoler, Jakson Mandredini
    Ferreira, Marcio Poletto
    Alievi, Marcelo Meller
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024,
  • [49] Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures
    Croley, J. Sawyer
    Morris, Randal P.
    Amin, Arsalan
    Lindsey, Ronald W.
    Gugala, Zbigniew
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (06): : 703 - 711
  • [50] Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis
    Salasek, Martin
    Jansova, Magdalena
    Kren, Jiri
    Pavelka, Tomas
    Weisova, Drahomira
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2015, 17 (01) : 39 - 49