Biomechanical comparison of four triangular osteosynthesis fixations for unilateral vertical sacral fractures

被引:5
|
作者
Ma, Yupeng [1 ,2 ]
Zhao, Yong [1 ,2 ]
Hong, Huanyu [1 ]
Huang, Tao [1 ]
Li, Yu [1 ]
机构
[1] Yantai Shan Hosp, Orthopaed Dept, 91 Jiefang Rd, Yantai 264008, Shandong, Peoples R China
[2] Yantai Shan Hosp, Yantai Key Lab Repair & Reconstruct Bone & Joint, Yantai, Peoples R China
基金
中国国家自然科学基金;
关键词
PERCUTANEOUS ILIOSACRAL SCREWS; SURGICAL DECOMPRESSION; SACROILIAC SCREWS; STABILITY; INJURIES; KINDS;
D O I
10.1038/s41598-023-31418-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To compare the stability and biomechanical characteristics of four commonly used triangular osteosynthesis techniques to treat unilateral vertical sacral fractures and provide a clinical application reference. Finite element models of Tile C-type pelvic ring injury (unilateral Denis II sacral fracture) were produced. In four models, sacral fractures were fixed with a combination of unilateral L5, unilateral L4, and L5 iliac lumbar fixation with lengthened or normal sacroiliac screws. The biomechanical properties of the four fixation models were measured and compared under bipedal stance and lumbar rotation. The fixation stability of the model with the lengthened sacroiliac screw was excellent, and the fracture end was stable. The stability of fixation using unilateral L4 and L5 segments was close to that of unilateral L5 segment fixation. Triangular osteosynthesis transverse stabilization devices using lengthened sacroiliac screws can increase the vertical stability of the sacrum after internal fixation and increase the stability of the fracture. When triangular osteosynthesis lumbar fixation segments were selected, simultaneous fixation of L4 and L5 segments versus only L5 segments did not significantly enhance the vertical stability of the sacrum or the stability of the fracture end.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Sacroiliac versus transiliac–transsacral screw osteosynthesis in osteoporotic pelvic fractures: a biomechanical comparison
    Raffael Cintean
    Cornelius Fritzsche
    Ivan Zderic
    Boyko Gueorguiev-Rüegg
    Florian Gebhard
    Konrad Schütze
    European Journal of Trauma and Emergency Surgery, 2023, 49 : 2553 - 2560
  • [32] A comparison of smooth and sharp kernel CT reconstructions in the detection of unilateral sacral fractures
    Willaume, Thibault
    Delmas, Louis
    Tochon, Ludivine
    Bierry, Guillaume
    SKELETAL RADIOLOGY, 2023, 52 (08) : 1519 - 1524
  • [33] A comparison of smooth and sharp kernel CT reconstructions in the detection of unilateral sacral fractures
    Thibault Willaume
    Louis Delmas
    Ludivine Tochon
    Guillaume Bierry
    Skeletal Radiology, 2023, 52 : 1519 - 1524
  • [34] Biomechanical Comparison of Different Pedicle Screw Fixations for Thoracolumbar Burst Fractures using Finite Element Method
    Wang, Dongmei
    Shi, Dufang
    Li, Xilei
    Dong, Jian
    Wang, Chunhui
    Chen, Shanguang
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 699 - +
  • [35] Sacroiliac versus transiliac-transsacral screw osteosynthesis in osteoporotic pelvic fractures: a biomechanical comparison
    Cintean, Raffael
    Fritzsche, Cornelius
    Zderic, Ivan
    Gueorguiev-Rueegg, Boyko
    Gebhard, Florian
    Schuetze, Konrad
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2023, 49 (06) : 2553 - 2560
  • [36] A biomechanical comparison of four different fixation methods for midshaft clavicle fractures
    Chen, Yang
    Yang, Yang
    Ma, Xinlong
    Xu, Weiguo
    Ma, Jianxiong
    Zhu, Shaowen
    Ma, Baoyi
    Xing, Dan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (01) : 13 - 19
  • [37] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Sascha Rausch
    Kajetan Klos
    Uwe Wolf
    Marc Gras
    Paul Simons
    Steffen Brodt
    Markus Windolf
    Boyko Gueorguiev
    International Orthopaedics, 2014, 38 : 1705 - 1710
  • [38] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Rausch, Sascha
    Klos, Kajetan
    Wolf, Uwe
    Gras, Marc
    Simons, Paul
    Brodt, Steffen
    Windolf, Markus
    Gueorguiev, Boyko
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1705 - 1710
  • [39] A Comprehensive Analysis With Minimum 1-Year Follow-up of Vertically Unstable Transforaminal Sacral Fractures Treated With Triangular Osteosynthesis
    Sagi, H. Claude
    Militano, Ulises
    Caron, Troy
    Lindvall, Eric
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (05) : 313 - 319
  • [40] Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
    Ming Ni
    Duo Wai-Chi Wong
    Jiong Mei
    Wenxin Niu
    Ming Zhang
    Science China(Life Sciences), 2016, (09) : 958 - 964