Research on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China

被引:0
|
作者
Jia, Xueying [1 ]
Zhang, Hui [1 ,2 ]
Yao, Xin [3 ]
Yang, Lei [3 ]
Ke, Zikang [1 ]
Yan, Junle [1 ]
Huang, Xiaoxi [1 ]
Jin, Shiyu [1 ]
机构
[1] Hubei Univ Technol, Sch Civil Engn Architecture & Environm, Wuhan 430068, Peoples R China
[2] Natl Univ Singapore, Coll Design & Engn, Singapore 117566, Singapore
[3] Cent South Architectural Design Inst Co Ltd, Wuhan 430061, Peoples R China
关键词
nearly zero-energy office buildings; complex and diverse climates; technology system; passive design; orthogonal experiment; DIFFERENT CLIMATE ZONES; PARAMETRIC ANALYSIS; EFFICIENCY; DESIGN; CONSUMPTION; NZEB; PERFORMANCE; SIMULATION; STANDARDS; SAVINGS;
D O I
10.3390/su151713061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2 & BULL;K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2 & BULL;K); the optimal level of KROOF in the CT zone is 0.15 W/(m2 & BULL;K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2 & BULL;K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.
引用
下载
收藏
页数:21
相关论文
共 50 条
  • [31] Energy-saving reconstruction research of old buildings in hot summer and cold winter regions
    Zhang Xu
    Lu Feng
    Yan Yinfei
    GREEN BUILDING TECHNOLOGIES AND MATERIALS II, 2013, 689 : 30 - 34
  • [32] Research Progress of Composite Thermal Insulation Wall in Hot Summer and Cold Winter Zone of China
    Liu, Hongmei
    Wu, Chengqun
    Xu, Yuanbin
    Zhu, Aidong
    ADVANCED CONSTRUCTION TECHNOLOGIES, 2014, 919-921 : 1725 - +
  • [33] Evaluation on energy and thermal performance for residential envelopes in hot summer and cold winter zone of China
    Yu, Jinghua
    Yang, Changzhi
    Tian, Liwei
    Liao, Dan
    APPLIED ENERGY, 2009, 86 (10) : 1970 - 1985
  • [34] Overview of research and development of nearly zero energy buildings in China
    Zhen Yu
    Caifeng Gao
    Jiaxin Yang
    Jianlin Wu
    Huan Zhang
    National Science Open, 2024, 3 (03) : 70 - 87
  • [35] Study on the Ventilation and Dehumidification System Integration Framework for City Buildings in Hot Summer and Cold Winter Zone
    Yu, Xiao-ping
    Fu, Xiang-zhao
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4270 - +
  • [36] Application of Nearly Zero Energy Buildings in Areas with Hot Summers and Cold Winters
    Liu, Qiuxin
    Tong, Liang
    Chen, Tianshou
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 1514 - 1521
  • [37] Optimization of energy-saving renovation technology for existing buildings in a hot summer and cold winter area
    Huo, Haie
    Deng, Xiaoxue
    Wei, Yanhuan
    Liu, Zhibo
    Liu, Mingrong
    Tang, Liu
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [38] Investigation of indoor thermal comfort of heritage buildings in hot summer and cold winter zone of China: A case study
    He, Danqiu
    Isa, Mohd Hafizal Mohd
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 53
  • [39] Thermal environment & thermal comfort - Humidity control of residential buildings in hot summer and cold winter zone in China
    Yu, XP
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 216 - 221
  • [40] Study on Daylighting and Energy Conservation Design of Transparent Envelope for office building in Hot Summer and Cold Winter Zone
    Yu, Jinghua
    Liu, Yu
    Xiong, Chao
    Huang, Jun Chao
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1642 - 1649