Research on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China

被引:0
|
作者
Jia, Xueying [1 ]
Zhang, Hui [1 ,2 ]
Yao, Xin [3 ]
Yang, Lei [3 ]
Ke, Zikang [1 ]
Yan, Junle [1 ]
Huang, Xiaoxi [1 ]
Jin, Shiyu [1 ]
机构
[1] Hubei Univ Technol, Sch Civil Engn Architecture & Environm, Wuhan 430068, Peoples R China
[2] Natl Univ Singapore, Coll Design & Engn, Singapore 117566, Singapore
[3] Cent South Architectural Design Inst Co Ltd, Wuhan 430061, Peoples R China
关键词
nearly zero-energy office buildings; complex and diverse climates; technology system; passive design; orthogonal experiment; DIFFERENT CLIMATE ZONES; PARAMETRIC ANALYSIS; EFFICIENCY; DESIGN; CONSUMPTION; NZEB; PERFORMANCE; SIMULATION; STANDARDS; SAVINGS;
D O I
10.3390/su151713061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2 & BULL;K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2 & BULL;K); the optimal level of KROOF in the CT zone is 0.15 W/(m2 & BULL;K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2 & BULL;K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Energy Consumption and Carbon Emissions of Nearly Zero-Energy Buildings in Hot Summer and Cold Winter Zones of China
    Ke, Zikang
    Liu, Xiaoxin
    Zhang, Hui
    Jia, Xueying
    Zeng, Wei
    Yan, Junle
    Hu, Hao
    Hien, Wong Nyuk
    [J]. SUSTAINABILITY, 2023, 15 (14)
  • [2] Indoor Humidity Environment Analysis of Nearly Zero Energy Residence in Hot Summer and Cold Winter Zone
    Su X.
    Tian S.
    [J]. Tongji Daxue Xuebao/Journal of Tongji University, 2020, 48 (05): : 725 - 732
  • [3] Indoor environment of nearly zero energy residential buildings with conventional air conditioning in hot-summer and cold-winter zone
    Dong J.
    Lan H.
    Liu Y.
    Wang X.
    Yu C.
    [J]. Energy and Built Environment, 2022, 3 (02): : 129 - 138
  • [4] Energy Sayings Potential for Buildings in Hot Summer and Cold Winter Zone
    Wang, Tianhong
    Yao, Jian
    [J]. ADVANCED RESEARCH ON COMPUTER EDUCATION, SIMULATION AND MODELING, PT II, 2011, 176 (02): : 434 - 437
  • [5] Applicability research on passive design of residential buildings in hot summer and cold winter zone in China
    Zhang, Hui
    Wang, Huihui
    Zhou, Xuan
    [J]. 3RD INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2017, 61
  • [6] Solar energy absorption effect of buildings in hot summer and cold winter climate zone, China
    Li, He
    Zhong, Ke
    Yu, Jia
    Kang, Yanming
    Zhai, Zhiqiang
    [J]. SOLAR ENERGY, 2020, 198 : 519 - 528
  • [7] Research on Climate Adaptability of Energy Conservation Building with Renewable Energy Sources in Hot-summer and Cold-winter Zone of China
    Hui Zhang
    Zhuang Yu
    [J]. RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1289 - 1296
  • [8] Analysis on Factors Affecting Energy Saving of Scientific Research buildings in Hot Summer and Cold Winter Zone
    Wang, Denghui
    Wang, Xinzhen
    Wu, Jindong
    [J]. 2018 INTERNATIONAL SYMPOSIUM ON MECHANICS, STRUCTURES AND MATERIALS SCIENCE (MSMS 2018), 2018, 1995
  • [9] Research on a Systematical Design Method for Nearly Zero-Energy Buildings
    Li, Ji
    Xu, Wei
    Cui, Ping
    Qiao, Biao
    Wu, Siyang
    Zhao, Chenghua
    [J]. SUSTAINABILITY, 2019, 11 (24)
  • [10] Application of PV window for office building in hot summer and cold winter zone of China
    Guo, Wenwen
    Qiu, Zhongzhu
    Li, Peng
    He, Jia
    Zhang, Yi
    Li, Qiming
    [J]. RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 81 - +