Patient-Reported Outcome Measures of a Novel Cortical Button System for Distal Biceps Tendon Repair: A Retrospective Study

被引:0
|
作者
Shean, Kate [1 ]
Chowdhury, Alex [1 ]
Wilcocks, Katharine [1 ]
Blyth, Daniel [1 ]
Elmorsy, Ahmed [1 ]
机构
[1] Salisbury NHS Fdn Trust, Trauma & Orthopaed, Salisbury, England
关键词
endobutton; suture button; distal biceps tendon repair; distal biceps rupture; bicep tendon; RUPTURES;
D O I
10.7759/cureus.38621
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There are a number of different techniques available for the repair of distal biceps tendon ruptures. Recent evidence has revealed satisfactory clinical outcomes for suture button techniques.Aims The aim of this study was to determine if the ToggleLocTM soft tissue fixation device (Zimmer Biomet, Warsaw, Indiana) confers satisfactory clinical outcomes in the surgical management of distal biceps ruptures.Methods Twelve consecutive patients underwent distal biceps repair using the ToggleLoc TM soft tissue fixation device over a two-year period. Patient-Reported Outcome Measures (PROMs) were collected by means of validated questionnaires on two occasions. Symptoms and function were quantified using the Disabilities of the Arm, Shoulder and Hand (DASH) score and the Oxford Elbow Score (OES). Patient-reported health scores were determined using the EQ-5D-3L (European Quality of Life 5 Dimensions 3 Level Version) questionnaire.Results The mean initial follow-up time was 10.4 months and the mean final follow-up time was 34.6 months. The mean DASH score at the initial follow-up was 5.9 (se = 3.6), compared to 2.9 (se = 1.0) at the final follow-up (p = 0.30). The mean OES at the initial follow-up was 91.5 (se = 4.1); and 91.5 (se = 5.2) at the final follow-up (p = 0.23). The mean EQ-5D-3L level sum score at the initial follow-up was 5.3 (se = 0.3); and 5.8 (se = 0.5) at the final follow-up (p = 0.34).Discussion The ToggleLocTM soft tissue fixation device confers satisfactory clinical outcomes, as determined by PROMS, in the surgical management of distal biceps ruptures.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Patient-Reported Outcome Measures in Nasal Valve Repair and Nasal Obstruction
    Feng, Max
    Derakhshan, Adeeb
    Fuller, Jennifer
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2025, 58 (02) : 205 - 214
  • [22] All-suture anchors for distal biceps tendon repair: a preliminary outcome study
    Sebastian Lappen
    Stephanie Geyer
    Pavel Kadantsev
    Maximilian Hinz
    Benjamin Kleim
    Hannes Degenhardt
    Andreas B. Imhoff
    Sebastian Siebenlist
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3271 - 3278
  • [23] All-suture anchors for distal biceps tendon repair: a preliminary outcome study
    Lappen, Sebastian
    Geyer, Stephanie
    Kadantsev, Pavel
    Hinz, Maximilian
    Kleim, Benjamin
    Degenhardt, Hannes
    Imhoff, Andreas B.
    Siebenlist, Sebastian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3271 - 3278
  • [24] Retrospective Study of the Distal Biceps Tendon Repair Using "All-suture" Soft Anchors
    Metikalc, Sreenivasulu
    Saleh, Zena
    Bader, Dov A.
    Sebastianelli, Wayne J.
    Sherbondy, Paul S.
    TECHNIQUES IN ORTHOPAEDICS, 2022, 37 (03) : 142 - 148
  • [25] STONE (STent Or NEphrostomy) study: Patient-reported outcome measures
    Schuil, H. W.
    Hendriks, N.
    Kamphuis, G. M.
    Oskam, B. C. H.
    Arends, T. J. H.
    Duijvesz, D.
    Van Der Heij, B.
    Tjiam, I.
    Scheepens, W. A.
    d'Ancona, F. C. H.
    Van Uhm, J. I. M.
    Van Roijen, J. H.
    Weltings, S.
    Van Der Meer, R. W.
    Bosmans, J. E.
    Pelger, R. C. M.
    Beerlage, H. P.
    Duijnhoven, R. G.
    Schout, B. M. A.
    EUROPEAN UROLOGY, 2024, 85 : S1755 - S1756
  • [26] Groin hernia repair, surgeon volume, and patient-reported outcome measures (PROMs)
    Coomer, Will
    Hamdani, Ashrah
    Patel, Gaural
    SURGERY, 2016, 159 (03) : 979 - 980
  • [27] Patient-reported outcome measures: an on-line system empowering patient choice
    Wilson, J.
    Arshad, F.
    Nnamoko, N.
    Whiteman, A.
    Ring, J.
    Roy, B.
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2014, 21 (04) : 725 - 729
  • [28] Usefulness of a Novel System for Feedback of Patient-Reported Outcome Measures in Children Recovering From Burns
    Riobueno-Naylor, Alexa
    Romo, Stephanie
    Kazis, Lewis
    Wang, Shirley
    Lydon, Martha
    Nelson, Judith
    Fowler, Laura
    Drexler, Alana
    Kogosov, Ann
    Haile, Haregnesh
    Ryan, Colleen M.
    Chang, Philip
    Warner, Petra
    Palmieri, Tina L.
    Lee, Austin F.
    Stoddard, Frederick
    Murphy, J. Michael
    Sheridan, Robert L.
    JOURNAL OF BURN CARE & RESEARCH, 2019, 40 (06): : 776 - 784
  • [29] Distal Biceps Tendon Repair Using a Modified Double-Incision Technique: Patient-Reported Outcomes With 10-Year Follow-up
    Razaeian, Sam
    Zhang, Dafang
    Harb, Afif
    Meller, Rupert
    Krettek, Christian
    Hawi, Nael
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (08)
  • [30] Patient-reported outcome and experience measures for quality improvement in pregnancy and childbirth care: a retrospective cohort study
    Klootwijk, Anouk
    Bakx, Pieter
    Franx, Arie
    Bijma, Hilmar
    Ernst-Smelt, Hiske
    Lamain-de Ruiter, Marije
    Posthumus, Anke
    van Rijn, Bas
    BMJ OPEN QUALITY, 2023, 12 (01)