Patient-Reported Outcome Measures of a Novel Cortical Button System for Distal Biceps Tendon Repair: A Retrospective Study

被引:0
|
作者
Shean, Kate [1 ]
Chowdhury, Alex [1 ]
Wilcocks, Katharine [1 ]
Blyth, Daniel [1 ]
Elmorsy, Ahmed [1 ]
机构
[1] Salisbury NHS Fdn Trust, Trauma & Orthopaed, Salisbury, England
关键词
endobutton; suture button; distal biceps tendon repair; distal biceps rupture; bicep tendon; RUPTURES;
D O I
10.7759/cureus.38621
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There are a number of different techniques available for the repair of distal biceps tendon ruptures. Recent evidence has revealed satisfactory clinical outcomes for suture button techniques.Aims The aim of this study was to determine if the ToggleLocTM soft tissue fixation device (Zimmer Biomet, Warsaw, Indiana) confers satisfactory clinical outcomes in the surgical management of distal biceps ruptures.Methods Twelve consecutive patients underwent distal biceps repair using the ToggleLoc TM soft tissue fixation device over a two-year period. Patient-Reported Outcome Measures (PROMs) were collected by means of validated questionnaires on two occasions. Symptoms and function were quantified using the Disabilities of the Arm, Shoulder and Hand (DASH) score and the Oxford Elbow Score (OES). Patient-reported health scores were determined using the EQ-5D-3L (European Quality of Life 5 Dimensions 3 Level Version) questionnaire.Results The mean initial follow-up time was 10.4 months and the mean final follow-up time was 34.6 months. The mean DASH score at the initial follow-up was 5.9 (se = 3.6), compared to 2.9 (se = 1.0) at the final follow-up (p = 0.30). The mean OES at the initial follow-up was 91.5 (se = 4.1); and 91.5 (se = 5.2) at the final follow-up (p = 0.23). The mean EQ-5D-3L level sum score at the initial follow-up was 5.3 (se = 0.3); and 5.8 (se = 0.5) at the final follow-up (p = 0.34).Discussion The ToggleLocTM soft tissue fixation device confers satisfactory clinical outcomes, as determined by PROMS, in the surgical management of distal biceps ruptures.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison
    Sebastian Siebenlist
    Arne Buchholz
    Julian Zapf
    Gunther H. Sandmann
    Karl F. Braun
    Frank Martetschläger
    Alexander Hapfelmeier
    Tobias M. Kraus
    Andreas Lenich
    Peter Biberthaler
    Florian Elser
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 926 - 933
  • [12] Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison
    Siebenlist, Sebastian
    Buchholz, Arne
    Zapf, Julian
    Sandmann, Gunther H.
    Braun, Karl F.
    Martetschlaeger, Frank
    Hapfelmeier, Alexander
    Kraus, Tobias M.
    Lenich, Andreas
    Biberthaler, Peter
    Elser, Florian
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 926 - 933
  • [13] Acute Distal Biceps Tendon Repair With Cortical Button Offers Good Functional Outcomes: A Retrospective Study Focusing on Range of Motion, Muscle Strength and Pain
    Mannan, Muhammad
    Hafeez, Usman
    Tsantanis, Pantelis
    Ajnin, Serajdin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [14] Patient-reported outcome measures and their association to the original Strickland classification after flexor tendon repair
    Renberg, Markus
    Svingen, Jonas
    Arner, Marianne
    Farnebo, Simon
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, : 661 - 667
  • [15] Managing Critical Patient-Reported Outcome Measures in Oncology Settings: System Development and Retrospective Study
    Strachna, Olga
    Asan, Onur
    Stetson, Peter D.
    JMIR MEDICAL INFORMATICS, 2022, 10 (11)
  • [16] A comparative clinical and functional assessment of cortical button versus suture anchor in distal biceps brachii tendon repair
    Reichert, Pawel
    Krolikowska, Aleksandra
    Kentel, Maciej
    Witkowski, Jaroslaw
    Gnus, Jan
    Satora, Wojciech
    Czamara, Andrzej
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (01) : 103 - 108
  • [17] Biomechanical Comparison of Interference Screw and Cortical Button With Screw Hybrid Technique for Distal Biceps Brachii Tendon Repair
    Arianjam, Afshin
    Camisa, William
    Leasure, Jeremi M.
    Montgomery, William H.
    ORTHOPEDICS, 2013, 36 (11) : E1371 - E1377
  • [18] Long-term patient-reported outcomes of open subpectoral biceps tenodesis with cortical button fixation
    Pianka, Mark A.
    Sundaram, Vishal
    Wolfe, Isabel
    Lezak, Bradley
    Moore, Michael R.
    Alaia, Michael J.
    Feldman, Andrew J.
    Jazrawi, Laith M.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, : 3201 - 3206
  • [19] | A Retrospective/Prospective Natural History Study of Football Players with Patient-Reported Outcome Measures
    Whitworth, Isaac
    Sinani, Ervin
    MUSCLE & NERVE, 2022, 66 : S52 - S53
  • [20] Patient-Reported Outcome Measures for Patients Undergoing Inguinal Hernia Repair
    Gram-Hanssen, Anders
    Tolstrup, Anders
    Zetner, Dennis
    Rosenberg, Jacob
    FRONTIERS IN SURGERY, 2020, 7