Patient-Reported Outcome Measures of a Novel Cortical Button System for Distal Biceps Tendon Repair: A Retrospective Study

被引:0
|
作者
Shean, Kate [1 ]
Chowdhury, Alex [1 ]
Wilcocks, Katharine [1 ]
Blyth, Daniel [1 ]
Elmorsy, Ahmed [1 ]
机构
[1] Salisbury NHS Fdn Trust, Trauma & Orthopaed, Salisbury, England
关键词
endobutton; suture button; distal biceps tendon repair; distal biceps rupture; bicep tendon; RUPTURES;
D O I
10.7759/cureus.38621
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There are a number of different techniques available for the repair of distal biceps tendon ruptures. Recent evidence has revealed satisfactory clinical outcomes for suture button techniques.Aims The aim of this study was to determine if the ToggleLocTM soft tissue fixation device (Zimmer Biomet, Warsaw, Indiana) confers satisfactory clinical outcomes in the surgical management of distal biceps ruptures.Methods Twelve consecutive patients underwent distal biceps repair using the ToggleLoc TM soft tissue fixation device over a two-year period. Patient-Reported Outcome Measures (PROMs) were collected by means of validated questionnaires on two occasions. Symptoms and function were quantified using the Disabilities of the Arm, Shoulder and Hand (DASH) score and the Oxford Elbow Score (OES). Patient-reported health scores were determined using the EQ-5D-3L (European Quality of Life 5 Dimensions 3 Level Version) questionnaire.Results The mean initial follow-up time was 10.4 months and the mean final follow-up time was 34.6 months. The mean DASH score at the initial follow-up was 5.9 (se = 3.6), compared to 2.9 (se = 1.0) at the final follow-up (p = 0.30). The mean OES at the initial follow-up was 91.5 (se = 4.1); and 91.5 (se = 5.2) at the final follow-up (p = 0.23). The mean EQ-5D-3L level sum score at the initial follow-up was 5.3 (se = 0.3); and 5.8 (se = 0.5) at the final follow-up (p = 0.34).Discussion The ToggleLocTM soft tissue fixation device confers satisfactory clinical outcomes, as determined by PROMS, in the surgical management of distal biceps ruptures.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The Intramedullary Cortical Button Technique for Distal Biceps Tendon Repair
    Buchholz, Arne
    Siebenlist, Sebastian
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (02) : 126 - 129
  • [2] The double intramedullary cortical button fixation for distal biceps tendon repair
    Sebastian Siebenlist
    Florian Elser
    Gunther H. Sandmann
    Arne Buchholz
    Frank Martetschläger
    Ulrich Stöckle
    Andreas Lenich
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1925 - 1929
  • [3] The double intramedullary cortical button fixation for distal biceps tendon repair
    Siebenlist, Sebastian
    Elser, Florian
    Sandmann, Gunther H.
    Buchholz, Arne
    Martetschlaeger, Frank
    Stoeckle, Ulrich
    Lenich, Andreas
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (11) : 1925 - 1929
  • [4] Sensory neurapraxia after distal biceps repair is not associated with patient-reported outcomes or satisfaction: a retrospective cohort study
    Clark, David S.
    Moore, Brady P.
    Somerson, Jeremy S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (12) : 2695 - 2701
  • [5] Bilateral simultaneous distal biceps tendon rupture repair with both cortical button and interference screw
    Tudisco, Cosimo
    Di Marcantonio, Arianna
    Cosseddu, Tomaso
    De Sanctis, Edoardo Giovannetti
    MINERVA ORTHOPEDICS, 2024, 75 (02): : 171 - 175
  • [6] Intramedullary Cortical Button Repair for Distal Biceps Tendon Rupture: A Single-Center Experience
    Siebenlist, Sebastian
    Schmitt, Andreas
    Imhoff, Andreas B.
    Lenich, Andreas
    Sandmann, Gunther H.
    Braun, Karl F.
    Kirchhoff, Chlodwig
    Biberthaler, Peter
    Buchholz, Arne
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (05): : 418.e1 - 418.e7
  • [7] Repair of Distal Biceps Tendon Ruptures Using a Combined Anatomic Interference Screw and Cortical Button
    Mazzocca, Augustus D.
    Bicos, James
    Arciero, Robert A.
    Romeo, Anthony A.
    Cohen, Mark S.
    Nicholson, Gregory
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2005, 6 (02): : 108 - 115
  • [8] Low incidence of tendon rerupture after distal biceps repair by cortical button and interference screw
    Cusick, Michael C.
    Cottrell, Benjamin J.
    Cain, Richard A.
    Mighell, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (10) : 1532 - 1536
  • [9] Single-Incision Technique for Repair of Distal Biceps Tendon Avulsions With Intramedullary Cortical Button
    Camp, Christopher L.
    Voleti, Pramod B.
    Corpus, Keith T.
    Dines, Joshua S.
    ARTHROSCOPY TECHNIQUES, 2016, 5 (02): : E303 - E307
  • [10] Biomechanical In Vitro Validation of Intramedullary Cortical Button Fixation for Distal Biceps Tendon Repair A New Technique
    Siebenlist, Sebastian
    Lenich, Andreas
    Buchholz, Arne
    Martetschlaeger, Frank
    Eichhorn, Stefan
    Heinrich, Petra
    Fingerle, Alexander
    Doebele, Stefan
    Sandmann, Gunther H.
    Millett, Peter J.
    Stoeckle, Ulrich
    Elser, Florian
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (08): : 1762 - 1768