Flexural Integrity Between the Individual Channels of Built-Up Cold-Formed Steel Beams

被引:2
|
作者
Suhaib, Mir Basar [1 ]
Tantray, Manzoor Ahmad [1 ]
机构
[1] Natl Inst Technol Srinagar, Dept Civil Engn, Srinagar, India
关键词
Cold-formed steel; Back-to-back channels; Built-up beam; Flexural strength; Screw connection; Composite action; DOUBLE-Z MEMBERS; DESIGN; SECTIONS; STRENGTH; BEHAVIOR;
D O I
10.1007/s13296-023-00708-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the influence of commonly used screw connections on the integrity of built-up beams formed by connecting two lipped channel sections in a back-to-back configuration. An experimental investigation on the behaviour of 6 built-up CFS beams connected by self-drilling screws is presented in this paper. The screw spacing was varied along the length as well as the depth of the beams. The test results indicate that the screw spacing has some influence on the capacity of the built-up beams. An increase in screw spacing leads to an undesirable separation of channels and thus has a negative impact on the composite action between the members. Finite element models were developed and after successful validation, a parametric study involving 124 models was carried out, to investigate the impact of larger longitudinal screw spacings on the integral behaviour of the beams. It was observed that the flexural capacity decreased by 11%, 14%, 17% and 19% when the longitudinal distance between the screws increased from 50 to 1050 mm for beams with web depths 150 mm, 200 mm, 250 mm and 300 mm respectively. It can be concluded that flexural capacity is directly proportional to the decrease in the screw spacing and increase in the number of screw rows. The results also indicate that the percentage decrease in strength is greater for beams with larger web depths. An idealized cross section assuming complete composite action was simulated for each web depth using FE modelling and the capacities of all the screw-connected "semi-rigid " beams were compared against it. The capacity of screw connected built-up beams with web depths 150 mm, 200 mm, 250 mm and 300 mm was found to be 0.71, 0.64, 0.61 and 0.59 times that of the idealized cross-section on average, respectively. The moment capacities of screw-connected beams were also compared against the theoretical values obtained from AISI S-100. It was observed that the design guidelines provided in AISI S-100 were unable to account for the reduction in the moment capacity due to the screw connection in built-up members. AISI S-100 is conservative by as much as 34%, 42%, 46% and 48% for beams with web depths 150 mm, 200 mm, 250 mm and 300 mm respectively.
引用
收藏
页码:503 / 520
页数:18
相关论文
共 50 条
  • [41] Fire resistance of built-up cold-formed steel columns
    Pires, Tiago A. C.
    do Rego Silva, Jose Jeferson
    dos Santos, Marina M. L.
    Costa, Leonardo Medeiros
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 177
  • [42] Experimental study of cold-formed steel built-up columns
    Meza, Francisco J.
    Becque, Jurgen
    Hajirasouliha, Iman
    THIN-WALLED STRUCTURES, 2020, 149
  • [43] Flexural behaviour of back-to-back built-up cold-formed steel channel beams: Experiments and finite element modelling
    Roy, Krishanu
    Lau, Hieng Ho
    Ting, Tina Chui Huon
    Chen, Boshan
    Lim, James B. P.
    STRUCTURES, 2021, 29 : 235 - 253
  • [44] Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures
    Sam, Varun Sabu
    Nammalvar, Anand
    Andrushia, Diana
    Gurupatham, Beulah Gnana Ananthi
    Roy, Krishanu
    BUILDINGS, 2024, 14 (08)
  • [45] Flexural behavior and design of cold-formed steel gapped back-to-back built-up beams with discontinuous connecting plates
    Wang, Liping
    Dawud, Mahmud B.
    Cai, Yancheng
    THIN-WALLED STRUCTURES, 2024, 205
  • [46] Sustainable Performance of a Modular Building System Made of Built-Up Cold-Formed Steel Beams
    Thirunavukkarasu, Kajaharan
    Kanthasamy, Elilarasi
    Gatheeshgar, Perampalam
    Poologanathan, Keerthan
    Rajanayagam, Heshachanaa
    Suntharalingam, Thadshajini
    Dissanayake, Madhushan
    BUILDINGS, 2021, 11 (10)
  • [47] Experimental investigations on built-up cold-formed steel beams connected by resistance spot welding
    Ungureanu, V
    Both, I
    Burca, M.
    Grosan, M.
    Neagu, C.
    Dubina, D.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 205 - 212
  • [48] Experimental investigations of cold-formed steel beams of corrugated web and built-up section for flanges
    Dubina, Dan
    Ungureanu, Viorel
    Gilia, Lucian
    THIN-WALLED STRUCTURES, 2015, 90 : 159 - 170
  • [49] Reliable design rules for cold-formed ferritic stainless steel closed built-up beams
    Karthik, C.
    Anbarasu, M.
    Dar, Mohammad Adil
    ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (05) : 722 - 742
  • [50] Behaviour and design of cold-formed steel built-up section beams with different screw arrangements
    Wang, Liping
    Young, Ben
    THIN-WALLED STRUCTURES, 2018, 131 : 16 - 32