Flexural Integrity Between the Individual Channels of Built-Up Cold-Formed Steel Beams

被引:2
|
作者
Suhaib, Mir Basar [1 ]
Tantray, Manzoor Ahmad [1 ]
机构
[1] Natl Inst Technol Srinagar, Dept Civil Engn, Srinagar, India
关键词
Cold-formed steel; Back-to-back channels; Built-up beam; Flexural strength; Screw connection; Composite action; DOUBLE-Z MEMBERS; DESIGN; SECTIONS; STRENGTH; BEHAVIOR;
D O I
10.1007/s13296-023-00708-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the influence of commonly used screw connections on the integrity of built-up beams formed by connecting two lipped channel sections in a back-to-back configuration. An experimental investigation on the behaviour of 6 built-up CFS beams connected by self-drilling screws is presented in this paper. The screw spacing was varied along the length as well as the depth of the beams. The test results indicate that the screw spacing has some influence on the capacity of the built-up beams. An increase in screw spacing leads to an undesirable separation of channels and thus has a negative impact on the composite action between the members. Finite element models were developed and after successful validation, a parametric study involving 124 models was carried out, to investigate the impact of larger longitudinal screw spacings on the integral behaviour of the beams. It was observed that the flexural capacity decreased by 11%, 14%, 17% and 19% when the longitudinal distance between the screws increased from 50 to 1050 mm for beams with web depths 150 mm, 200 mm, 250 mm and 300 mm respectively. It can be concluded that flexural capacity is directly proportional to the decrease in the screw spacing and increase in the number of screw rows. The results also indicate that the percentage decrease in strength is greater for beams with larger web depths. An idealized cross section assuming complete composite action was simulated for each web depth using FE modelling and the capacities of all the screw-connected "semi-rigid " beams were compared against it. The capacity of screw connected built-up beams with web depths 150 mm, 200 mm, 250 mm and 300 mm was found to be 0.71, 0.64, 0.61 and 0.59 times that of the idealized cross-section on average, respectively. The moment capacities of screw-connected beams were also compared against the theoretical values obtained from AISI S-100. It was observed that the design guidelines provided in AISI S-100 were unable to account for the reduction in the moment capacity due to the screw connection in built-up members. AISI S-100 is conservative by as much as 34%, 42%, 46% and 48% for beams with web depths 150 mm, 200 mm, 250 mm and 300 mm respectively.
引用
收藏
页码:503 / 520
页数:18
相关论文
共 50 条
  • [21] Numerical investigation of built-up cold-formed steel beams with corrugated web
    Ungureanu, V
    Lukacevic, I
    Both, I
    Burca, M.
    Dubina, D.
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 1193 - 1200
  • [22] Laser welded built-up cold-formed steel beams: Experimental investigations
    Landolfo, R.
    Mammana, O.
    Portioli, F.
    Di Lorenzo, G.
    Guerrieri, M. R.
    THIN-WALLED STRUCTURES, 2008, 46 (7-9) : 781 - 791
  • [23] Behaviour and design of cold-formed steel built-up I-beams composed of four channels
    Amali, D.
    Anbarasu, M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 217
  • [24] Flexural Strength Evaluation for Cold-Formed Steel Lip-Reinforced Built-Up I-Beams
    Zhou, Xu-hong
    Shi, Yu
    ADVANCES IN STRUCTURAL ENGINEERING, 2011, 14 (04) : 597 - 611
  • [25] Cold-formed ferritic stainless steel closed built-up beams: Flexural behaviour and numerical parametric study
    Karthik, C.
    Anbarasu, M.
    THIN-WALLED STRUCTURES, 2021, 164
  • [26] Cold-formed ferritic stainless steel closed-section built-up beams: Tests and flexural response
    Karthik, C.
    Anbarasu, M.
    Dar, Mohammad Adil
    THIN-WALLED STRUCTURES, 2022, 180
  • [27] Investigation on flexural strength of cold-formed thin-walled steel beams with built-up box section
    Li, Ying-Lei
    Li, Yuan-Qi
    Shen, Zu-Yan
    THIN-WALLED STRUCTURES, 2016, 107 : 66 - 79
  • [28] The mechanics of built-up cold-formed steel members
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    Zhang, Hao
    THIN-WALLED STRUCTURES, 2020, 154 (154)
  • [29] Study of cold-formed steel built-up column
    Aruna, G.
    Sukumar, S.
    International Journal of Earth Sciences and Engineering, 2015, 8 (05): : 2074 - 2078
  • [30] A Parametric Study on the Flexural Capacity of Cold-Formed Steel Stacked Built-up Sections
    Rezaeian, Hooman
    Andarini, Rhonita
    Bock, Marina
    Yekrangnia, Mohammad
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2024, 24 (05) : 1142 - 1153